4. No draining
Set rinse or spin.
Start the machine.
Check if the E lectro-magnet iron acts?
Measu re the
voltage of the two ends of
the E lectro-magnet ir on
Measure the voltage
of the two ends of the output
of the computer sequencer.
Check the drain system like
the drain valve etc.
Re place the E lectro-magnet ir on
Replace the wire unit.
Replace the computer
sequencer.
At this time check if the Electro-magnet iron
works normally.
Exist
No
No Exist
No Exist
Exist
5. Keep filling water
If the water can fill into
the water inlet valve
If the water can fill into
the water inlet valve
Check if the wire connecting
the computer board to the
water level s witch is bad?
Selec t "low " water leve l
and start the machine to
check if the gas cell
has water?
Check if the gas guide sys tem
is blocked?
No
No
No
No
Replace the water level switch.
Replace the water inlet valve.
Replace the computersequencer.
Replace the wire unit.
It leaks gas. Please check and
repair the gas guide system.
Please smear 801 glue in installation
of the connectingpipe.
Please smear 801 glue in installation
of the gas cell cover.
At this time please check if the
water inlet valve is well.
Blow from the connecting pipe to the
water level sensor and gas cell to see
if there's blocking.
Clear various factors like
the foreign Materials.
No
Yes
Yes
Yes
Yes
Yes
Switch on the power. Do not
push the "Start/Pause" button.
Open the water faucet with out
swit ching on the power.
Trouble-shooting
T able
Roll up normally