background image

8

T/P valve 

Safety valve

(For Indirect System)

 

Note:

1.The heat transfer fluid is a food grade propylene glycol and is not toxic. However, care must 

    be taken when handling not to spill or accidentally consume.

2.It is normal that some heat transfer fluid may flow out from the safety valve as the heat 

    transfer fluid is expanded due to the high solar energy collected.

3.The safety valve should be left open to the atmosphere and its outlet should not be blocked.

    The solar storage tank be filled with water before charging the heat transfer fluid with the 

    closed circuit fluid.

4.The service valve, hose and the funnel are not supplied.   

 

1.Open the cold water inlet valve, and inject water into the water tank through the 

    outlet.

2.When the air totally exhausts and the water flow is continuous, close the mixing valve and 

    watch carefully to find out whether the tank is leaking water.

3.Make sure that the cold water inlet is always open while using the water heater.   

tap water 

1.Cut off the power and cold water supply.

2.Disconnect the T/P valve, let water flow out until empty.

Please refer to the

to connect the valves and pipe fittings.

1.Install the temperature and pressure

    valve(T/P valve) to the T/P valve joint

    of the water tank.

Note

A T/P valve shall be installed to the tank.

It is normal that some water drops may

flow out from the pressure relief hole as

the water is expanded with heat while

the water temperature in the heater

gets higher.

Continuous leakage of water from the

valve and its drain line may indicate a

problem with the water heater .Failure

to operate the T/P valve easing gear at 

least once every six months may 

result in the water heater exploding.

The T/P valve should be replaced at

intervals not exceeding 5 years, or

more frequently in areas where there

is a high incidence of water deposits.

2.Install the cold water line, non-return

    valve and the stop valve to the cold

    water inlet of the tank.                  

 following sketch map 

 

   

230V

50Hz

Cold water

Stop valve

Non-return valve

Hot water

Mixing valve

Warm water

Insulat

ed pipe

Note

A non-return valve(not supplied) 

MUST BE installed on the cold water line
 to the water tank .

drain line

turn until water 
the drain line-lower gently

flows from 

T/P valve

Installation Introduction

Connection of Valves and Pipe Fittings

Water Injection into Water Tank

How to Drain Water Tank

Содержание TP180JEF

Страница 1: ...0RNL TP300JNL TP180RNF TP180JNF TP300RNF TP300JNF without electric heater Manual for Installation and Operation Solar Water Heater WARNING Use copper pipe ONLY Plastic pipe MUST NOT be used It is a requirement of a solar water heater installation that all pipe work be in copper and not plastic due to the effects of high water temperatures ...

Страница 2: ...ection of Pipeline Filling the Heat Exchange Jacket For Indirect System 2 8 How to Drain Water Tank Note Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of ...

Страница 3: ...ng use of the appliance by a person responsible for their safety physical The water heater must be connected to a switch in the fixed wiring eg a Circuit fixed on the wall that can provide the appliance all pole disconnection from the supply mains The switch shall be rated 250V 16A at least Don t disconnect the grounding wire at any time Breaker Make sure all connection components of the pipeline ...

Страница 4: ... angle is above 20 fixation equipment shall be added to fasten the water tank such as the steel wire rope the 2 Collectors shall be installed facing the south as far as possible completed and before the system is full of water it is IMPORTANT to check the following depending upon the positioning of the frame on the roof and any minor fall the roof may have ensure the collector rail is either horiz...

Страница 5: ...llector installations couple the solar collectors together using the collector unions 6 Ensure the solar collectors are well seated in the collector rail Note Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors If the collector glass becomes dirty hose down or if the solar collectors are accessible wash...

Страница 6: ... nails or with embedded expansion bolts 5 Position the water storage tank in the correct configuration and well seated in the tank frame washers fixed on Note To avoid any scratch the plastic film covering the tank shall be removed only upon completion of the installation and sharp tools such as a wallpaper cutter are prohibited from being used to remove the film If your system is for flat roof pl...

Страница 7: ...sulation must be weatherproof and UV resistant 1 Remove the 0 3MPa safety valve from the water tank This is the fill level for the transfer fluid and will allow air to escape during filling 2 With the aid of a funnel and hose connected to the open service valve pour water into the funnel until water flows from the vent of the 0 3MPa safety valve 3 Close the service valve tap and assembly the 0 3MP...

Страница 8: ...pty Please refer to the to connect the valves and pipe fittings 1 Install the temperature and pressure valve T P valve to the T P valve joint of the water tank Note A T P valve shall be installed to the tank It is normal that some water drops may flow out from the pressure relief hole as the water is expanded with heat while the water temperature in the heater gets higher Continuous leakage of wat...

Страница 9: ...e wiring of PE and L N lines please refer to below The length of PE wire shall be longer than L N wire so that the L N conductors become taut before the earthing conductor if the cord slips out of the cord anchorage For more information please refer to the wiring diagram wiring 2 L Live wire red N Neutral wire blue E Earth wire yellow and green TB Terminal block TS Thermostat HE Heating Element 1 ...

Страница 10: ...EF TP180JNF TP300JNF Names of parts Quantities 2 0m2 2 0m2 4 0m2 4 0m2 TP180REL TP300REL TP180RNL TP300RNL TP180REF TP300REF TP180RNF TP300RNF Packing box of water tank Packing box of water tank frame Packing box of solar collector Packing box of cover Water tank 1 1 1 1 1 1 3 1 3 1 2 2 1 8 8 6 6 1 0 1set 1set 1set 1set 1set 1 1 2 2 T P valve Safety valve Collector connector Collector end plug Col...

Страница 11: ...NL TP180REF TP180RNF How to fix the water tank Water tank Frame Self tapping screw I II II I I II Exploded View Exploded View of One Collector 14 14 10 1 11 3 3 4 5 6 16 15 7 5 9 1 10 3 8 7 18 5 11 17 2 8 7 9 2 3 4 5 6 7 ...

Страница 12: ... TP300RNL How to fix the water tank Water tank Frame Self tapping screw I II I I II II Exploded View Exploded View of Two Collectors 9 14 11 3 13 13 5 9 1 2 3 4 5 6 7 11 10 10 3 8 18 5 13 13 7 8 7 2 2 14 14 1 3 4 5 5 7 15 16 17 10 ...

Страница 13: ...L TP180JEF TP180JNF How to fix the water tank Water tank Frame Self tapping screw I II I II Exploded View Exploded View of One Collector 11 14 14 10 1 12 9 18 5 5 5 4 3 3 8 7 2 1 12 11 10 9 5 15 5 5 4 3 2 3 8 7 6 16 17 6 ...

Страница 14: ...P300JNF How to fix the water tank Water tank Frame Self tapping screw I II II 4 5 13 13 12 11 9 2 3 8 7 10 5 15 16 17 5 6 2 2 3 7 8 12 11 I I II Exploded View Exploded View of Two Collectors 14 14 14 10 1 3 9 18 13 13 3 2 1 4 5 6 5 5 ...

Страница 15: ...not enough The electrical heater is not on Use the electric heating method Contact the installers Contact the installers The electrical heater is damaged The heat transfer fluid is not enough The electrical connection is damaged Whether the water use points is or the water valve is opened blocked Clean the block material and open the water valve Adjust it again Switch off the power supply before c...

Страница 16: ...0040503857 20150508 ...

Отзывы: