The product uses high-efficient flat collectors fixed on the aluminum frame.

1.Select a suitable position for the solar collectors.

2.Determine the location of the collector rail, and hook the collector straps to the collector rail.

3.Remove the tiles from the place reserved for the collector on the roof, then fix the collector 

    strap to the rafters, using self-drilling screws or stainless steel nails (or with embedded 

    expansion bolts).

4.Position the solar collectors in the correct configuration with the lower ends seated in the 

    collector rail.

5.For multiple solar collector installations, couple the solar collectors together using the 

    collector unions.

6.Ensure the solar collectors are well seated in the collector rail.    

Note

Ensure the glass on your solar collectors is free of dust, salt spray or any other matter, which 

may reduce the effectiveness of the solar collectors. If the collector glass becomes dirty, hose 

down or if the solar collectors are accessible, wash the collector glass with water and a soft 

brush when the solar collectors are cool.   

If your system is for flat roof, please refer to the Exploded View of  System for flat 

page 11 to 14.  

roof on 

Collector rail

Collector strap

Solar collector

Collector strap

Collector rail

Collector rail

Tiles

Collector clamp

5

Installation Introduction

Installation of Solar Collector

Содержание TP180JEF

Страница 1: ...0RNL TP300JNL TP180RNF TP180JNF TP300RNF TP300JNF without electric heater Manual for Installation and Operation Solar Water Heater WARNING Use copper pipe ONLY Plastic pipe MUST NOT be used It is a requirement of a solar water heater installation that all pipe work be in copper and not plastic due to the effects of high water temperatures ...

Страница 2: ...ection of Pipeline Filling the Heat Exchange Jacket For Indirect System 2 8 How to Drain Water Tank Note Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of ...

Страница 3: ...ng use of the appliance by a person responsible for their safety physical The water heater must be connected to a switch in the fixed wiring eg a Circuit fixed on the wall that can provide the appliance all pole disconnection from the supply mains The switch shall be rated 250V 16A at least Don t disconnect the grounding wire at any time Breaker Make sure all connection components of the pipeline ...

Страница 4: ... angle is above 20 fixation equipment shall be added to fasten the water tank such as the steel wire rope the 2 Collectors shall be installed facing the south as far as possible completed and before the system is full of water it is IMPORTANT to check the following depending upon the positioning of the frame on the roof and any minor fall the roof may have ensure the collector rail is either horiz...

Страница 5: ...llector installations couple the solar collectors together using the collector unions 6 Ensure the solar collectors are well seated in the collector rail Note Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors If the collector glass becomes dirty hose down or if the solar collectors are accessible wash...

Страница 6: ... nails or with embedded expansion bolts 5 Position the water storage tank in the correct configuration and well seated in the tank frame washers fixed on Note To avoid any scratch the plastic film covering the tank shall be removed only upon completion of the installation and sharp tools such as a wallpaper cutter are prohibited from being used to remove the film If your system is for flat roof pl...

Страница 7: ...sulation must be weatherproof and UV resistant 1 Remove the 0 3MPa safety valve from the water tank This is the fill level for the transfer fluid and will allow air to escape during filling 2 With the aid of a funnel and hose connected to the open service valve pour water into the funnel until water flows from the vent of the 0 3MPa safety valve 3 Close the service valve tap and assembly the 0 3MP...

Страница 8: ...pty Please refer to the to connect the valves and pipe fittings 1 Install the temperature and pressure valve T P valve to the T P valve joint of the water tank Note A T P valve shall be installed to the tank It is normal that some water drops may flow out from the pressure relief hole as the water is expanded with heat while the water temperature in the heater gets higher Continuous leakage of wat...

Страница 9: ...e wiring of PE and L N lines please refer to below The length of PE wire shall be longer than L N wire so that the L N conductors become taut before the earthing conductor if the cord slips out of the cord anchorage For more information please refer to the wiring diagram wiring 2 L Live wire red N Neutral wire blue E Earth wire yellow and green TB Terminal block TS Thermostat HE Heating Element 1 ...

Страница 10: ...EF TP180JNF TP300JNF Names of parts Quantities 2 0m2 2 0m2 4 0m2 4 0m2 TP180REL TP300REL TP180RNL TP300RNL TP180REF TP300REF TP180RNF TP300RNF Packing box of water tank Packing box of water tank frame Packing box of solar collector Packing box of cover Water tank 1 1 1 1 1 1 3 1 3 1 2 2 1 8 8 6 6 1 0 1set 1set 1set 1set 1set 1 1 2 2 T P valve Safety valve Collector connector Collector end plug Col...

Страница 11: ...NL TP180REF TP180RNF How to fix the water tank Water tank Frame Self tapping screw I II II I I II Exploded View Exploded View of One Collector 14 14 10 1 11 3 3 4 5 6 16 15 7 5 9 1 10 3 8 7 18 5 11 17 2 8 7 9 2 3 4 5 6 7 ...

Страница 12: ... TP300RNL How to fix the water tank Water tank Frame Self tapping screw I II I I II II Exploded View Exploded View of Two Collectors 9 14 11 3 13 13 5 9 1 2 3 4 5 6 7 11 10 10 3 8 18 5 13 13 7 8 7 2 2 14 14 1 3 4 5 5 7 15 16 17 10 ...

Страница 13: ...L TP180JEF TP180JNF How to fix the water tank Water tank Frame Self tapping screw I II I II Exploded View Exploded View of One Collector 11 14 14 10 1 12 9 18 5 5 5 4 3 3 8 7 2 1 12 11 10 9 5 15 5 5 4 3 2 3 8 7 6 16 17 6 ...

Страница 14: ...P300JNF How to fix the water tank Water tank Frame Self tapping screw I II II 4 5 13 13 12 11 9 2 3 8 7 10 5 15 16 17 5 6 2 2 3 7 8 12 11 I I II Exploded View Exploded View of Two Collectors 14 14 14 10 1 3 9 18 13 13 3 2 1 4 5 6 5 5 ...

Страница 15: ...not enough The electrical heater is not on Use the electric heating method Contact the installers Contact the installers The electrical heater is damaged The heat transfer fluid is not enough The electrical connection is damaged Whether the water use points is or the water valve is opened blocked Clean the block material and open the water valve Adjust it again Switch off the power supply before c...

Страница 16: ...0040503857 20150508 ...