Air conditioner 

seems to run 

too much or 

over cycle 

The use of more efficient 

components may cause the air 

conditioner to run longer than 

an older model, but the total 

energy consumption will be 

less.  

Newer air conditioners do not 

emit the “blast” of cold air you 

may be accustomed to from 

older air conditioners, but this 

is not an indication of lesser 

cooling capacity or efficiency. 

 A higher capacity air 

conditioner may be required, 

depending on the size of the 

room being cooled. 

1. Verify the thermostat 

is cycling the unit on and 

off properly. 

2. Inspect the wiring to 

the Control PCB. 

3. Verify the unit is 

properly charged with 

refrigerant 

P.C.B.-

CONTROL 

BOARD 

AC-

5210-

139  

N/A 

N/A 

Remote not 

working  

Verify the batteries are good  

Verify nothing is blocking the 

receiver 

Verify there are no fluorescent 

lights or other sources of RF 

interference near the unit. 

 
 
 
 
 
 
 
 
 

1. Inspect the wiring to 

and from the Control 

PCB 

2. Inspect the remote 

sensor for signs of poor 

connection 

P.C.B.-

CONTROL 

BOARD 

AC-

5210-

139  

N/A 

N/A 

Содержание Symptom

Страница 1: ...s to provide the technicians with repair advice that can be used to improve the first time fix ratio as well as reduce shotgun troubleshooting Model CPN10XHJ Modified Date 8 8 2012 Symptom Customer advice Repair Guidance Primary Part Description Primary Part Secondary Part Description Secon dary Part Musty Smell Verify the Exhaust kit is not obstructed Verify the water tank is not full If mold or ...

Страница 2: ...Verify the thermostat is cycling the unit on and off properly 5 Verify the unit is properly charged with refrigerant WHEEL BLOWER CONDENS ER AC 8000 30 N A N A STOP is shown on the LCD display This indicates the internal water tank has filled with water and needs to be drained Open the drain plug on the back of the unit and allow the unit to drain into a shallow bowl 1 Inspect the drain tube and p...

Страница 3: ...t is cycling the unit on and off properly 3 Inspect the wiring to the Control PCB 4 Verify the unit is properly charged with refrigerant WHEEL BLOWER CONDENS ER AC 8000 30 N A N A Cannot adjust the Temperature Temperature buttons do not work When using Dehumidify or Fan Mode the temperature adjustment button is disabled Inspect the wiring from the Display PCB to the Control PCB P C B CONTROL BOARD...

Страница 4: ... necessary 1 Verify the thermostat is cycling the unit on and off properly 2 Inspect the wiring to the Control PCB 3 Verify the unit is properly charged with refrigerant P C B CONTROL BOARD AC 5210 139 N A N A No Cooling Fans are NOT running Verify the thermostat is set for a value 10 degrees lower than the room temperature Verify the air filter is clear Verify there is nothing obstructing air flo...

Страница 5: ...000 30 Fan Motor AC 4550 309 A Household fuse has blown or a circuit Breaker has been tripped It is recommended that an AC unit have its own circuit Be sure the time delay fuse or circuit breaker of the correct capacity Do not use an extension cord with this or any other appliance You are trying to restart the air conditioner too soon after turning off the air conditioner Wait at least 3 minutes a...

Страница 6: ...cy A higher capacity air conditioner may be required depending on the size of the room being cooled 1 Verify the thermostat is cycling the unit on and off properly 2 Inspect the wiring to the Control PCB 3 Verify the unit is properly charged with refrigerant P C B CONTROL BOARD AC 5210 139 N A N A Remote not working Verify the batteries are good Verify nothing is blocking the receiver Verify there...

Страница 7: ...tability for their purposes prior to use In no event will Haier America Trading LLC be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information or the product to which Information refers Disclaimer 2 This material is published for informational purposes only and intended for use only by persons qualified for the specific tasks shown Qualified personne...

Отзывы: