Haier Symptom Скачать руководство пользователя страница 3

Service Support System 

 

 

CPN10XHJ

 

  Page 3 of 7 

 

Poor cooling 

Verify the thermostat is set for 

a value ~ 10 degrees lower 

than the room temperature 

Verify the air filter is clear 

Verify there is nothing 

obstructing air flow on the 

outside of the unit and the 

exhaust kit is venting outdoors 

Verify the unit is not frosted 

over and the drain is working 

properly 

Verify the water tank is empty, 

drain the tank if necessary 

Verify the unit is the proper 

size for the room being cooled. 

1. Verify the fan motors 

are working properly and 

the fan blades are 

attached securely to the 

motors 

2. Verify the thermostat 

is cycling the unit on and 

off properly. 

3. Inspect the wiring to 

the Control PCB. 

4. Verify the unit is 

properly charged with 

refrigerant 

WHEEL-

BLOWER 

CONDENS

ER 

AC-

8000-30  

N/A 

N/A 

Cannot adjust 

the 

Temperature  

(Temperature 

buttons do not 

work) 

When using Dehumidify or 

Fan Mode the temperature 

adjustment button is disabled 

Inspect the wiring from 
the Display PCB to the 

Control PCB 

 
 
 
 

P.C.B.-

CONTROL 

BOARD 

AC-

5210-

139  

N/A 

N/A 

The Fan 

speed cannot 

be adjusted 

When Dehumidify mode is 

selected and the room 

temperature is lower than 77 

degrees the fan speed is fixed 

at the low setting 

1. Verify the fan motors 

are working properly and 

the fan blades are 

attached securely to the 

motors.  

2. Inspect the wiring 

from to and from the fan 

motor. 

P.C.B.-

CONTROL 

BOARD 

AC-

5210-

139  

WHEEL-

BLOWER 

CONDENS

ER 

AC-

8000-

30  

Содержание Symptom

Страница 1: ...s to provide the technicians with repair advice that can be used to improve the first time fix ratio as well as reduce shotgun troubleshooting Model CPN10XHJ Modified Date 8 8 2012 Symptom Customer advice Repair Guidance Primary Part Description Primary Part Secondary Part Description Secon dary Part Musty Smell Verify the Exhaust kit is not obstructed Verify the water tank is not full If mold or ...

Страница 2: ...Verify the thermostat is cycling the unit on and off properly 5 Verify the unit is properly charged with refrigerant WHEEL BLOWER CONDENS ER AC 8000 30 N A N A STOP is shown on the LCD display This indicates the internal water tank has filled with water and needs to be drained Open the drain plug on the back of the unit and allow the unit to drain into a shallow bowl 1 Inspect the drain tube and p...

Страница 3: ...t is cycling the unit on and off properly 3 Inspect the wiring to the Control PCB 4 Verify the unit is properly charged with refrigerant WHEEL BLOWER CONDENS ER AC 8000 30 N A N A Cannot adjust the Temperature Temperature buttons do not work When using Dehumidify or Fan Mode the temperature adjustment button is disabled Inspect the wiring from the Display PCB to the Control PCB P C B CONTROL BOARD...

Страница 4: ... necessary 1 Verify the thermostat is cycling the unit on and off properly 2 Inspect the wiring to the Control PCB 3 Verify the unit is properly charged with refrigerant P C B CONTROL BOARD AC 5210 139 N A N A No Cooling Fans are NOT running Verify the thermostat is set for a value 10 degrees lower than the room temperature Verify the air filter is clear Verify there is nothing obstructing air flo...

Страница 5: ...000 30 Fan Motor AC 4550 309 A Household fuse has blown or a circuit Breaker has been tripped It is recommended that an AC unit have its own circuit Be sure the time delay fuse or circuit breaker of the correct capacity Do not use an extension cord with this or any other appliance You are trying to restart the air conditioner too soon after turning off the air conditioner Wait at least 3 minutes a...

Страница 6: ...cy A higher capacity air conditioner may be required depending on the size of the room being cooled 1 Verify the thermostat is cycling the unit on and off properly 2 Inspect the wiring to the Control PCB 3 Verify the unit is properly charged with refrigerant P C B CONTROL BOARD AC 5210 139 N A N A Remote not working Verify the batteries are good Verify nothing is blocking the receiver Verify there...

Страница 7: ...tability for their purposes prior to use In no event will Haier America Trading LLC be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information or the product to which Information refers Disclaimer 2 This material is published for informational purposes only and intended for use only by persons qualified for the specific tasks shown Qualified personne...

Отзывы: