background image

4

49-5000477  Rev. 1

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

READ AND SAVE THESE INSTRUCTIONS

WARNING

 For your safety, the information in this manual must be followed to minimize the risk of fire, electric 

shock or personal injury.

•  Use this appliance only for its intended purpose as 

described in this Owner’s Manual. 

•  This air conditioner must be properly installed in 

accordance with the Installation Instructions before it is 
used. 

•  Never unplug your air conditioner by pulling on the power 

cord. Always grip plug firmly and pull straight out from the 
receptacle. 

•  Replace immediately all electric service cords that have 

become frayed or otherwise damaged. A damaged power 
supply cord must be replaced with a new power supply cord 
obtained from the manufacturer and not repaired. Do not 
use a cord that shows cracks or abrasion damage along its 
length or at either the plug or connector end. 

•  Turn the unit OFF and unplug your air conditioner before 

cleaning. 

•  For your safety…do not store or use combustible materials, 

gasoline or other flammable vapors or liquids in the vicinity 
of this or any other appliance.

•  If the receptacle does not match the plug, the receptacle 

must be changed out by a qualified electrician.

 

•  Do not use means to accelerate the defrosting process 

or to clean, other than those recommended by the 
manufacturer.

•  The appliance shall be stored in a room without 

continuously operating ignition sources (for example: open 
flames, an operating gas appliance or an operating electric 
heater.

•  Do not pierce or burn refrigerant tubing. Be aware that 

refrigerants may not contain an odor.

•  Keep ventilation openings clear of obstruction.
•  When handling, installing, and operating the appliance, care 

should be taken to avoid damage to the refrigerant tubing.

•  Do not drill holes in the unit.
•  Maintenance, cleaning, and service should only be 

performed by technicians properly trained and qualified in 
the use of flammable refrigerants.

•  GE Appliances does not support any servicing of the air 

conditioner.

•  Dispose of air conditioner in accordance with Federal and 

Local Regulations. Flammable refrigerants require special 
disposal procedures. Contact your local authorities for the 
environmentally safe disposal of your air conditioner.

WARNING

Risk of Fire or Explosion.  This unit contains flammable refrigerant.
Additional safety precautions must be followed.

SAFETY INFORMATION

Содержание QHEC05

Страница 1: ...5 Room Air Conditioner Acondicionadores de Aire Para Sala 49 5000477 Rev 1 11 22 GEA Design may vary by model number Some models may have an additional letter after the model number El dise o puede va...

Страница 2: ...2 49 5000477 Rev 1...

Страница 3: ...____________________________________________________ Date of purchase HAIER WEBSITE Have a question or need assistance with your appliance Try the Haier Website 24 hours a day any day of the year You...

Страница 4: ...vicinity of this or any other appliance If the receptacle does not match the plug the receptacle must be changed out by a qualified electrician Do not use means to accelerate the defrosting process o...

Страница 5: ...is appliance Power cord includes a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST RESET into...

Страница 6: ...g Select1 3onthe dialwithLCoolselected 2 ModeControl HCoolandLCoolprovidecoolingwithdifferentfanspeeds HFanandLFanprovidecirculationandfilteringwithout cooling NOTE IfyoumovetheTemperaturecontrolfroma...

Страница 7: ...e the filter Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher CAUTION without a filter because dirt and lint will clog it...

Страница 8: ...models require a 115 120 volt AC 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the...

Страница 9: ...v 1 9 Side Curtain Frame Type B 9 Foam top window gasket Side Curtain 2 Top mounting rail Air conditioner Window locking bracket 1 Side Brackets 2 Appearance may vary Left Right Type A 3 INSTALLATION...

Страница 10: ...st be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model 2 A storm window frame will...

Страница 11: ...bracket into the unit and into the window sill using two 1 wood screws provided repeate on other side Width of window opening Center line 4 INSTALL THE AIR CONDITIONER IN THE WINDOW continues D Bring...

Страница 12: ...similarly constructed windows attach the window locking bracket to the window side jamb with one Type B screw B Cut the foam top window gasket to the window width C Stuff the foam between the glass a...

Страница 13: ...irflow is restricted Make sure there are not curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set properly Turn the temperature control to a higher nu...

Страница 14: ...drip from the outdoor sideof the unit The fan may run even when the compressor does not Water droplets being thrown against the outside coils can make a pinging noise This helps cool the condenser Yo...

Страница 15: ...es Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Replacement of house fuses or resetti...

Страница 16: ...16 49 5000477 Rev 1 NOTES...

Страница 17: ...o Usted tambi n puede comprar m s electrodom sticos maravillosos de Haier y aprovechar todos nuestros servicios de soporte a trav s de Internet dise ados para su conveniencia En EE UU Haierappliances...

Страница 18: ...no coincide con el enchufe el cambio del mismo deber ser realizado por un electricista calificado ADVERTENCIA A fin de acelerar el proceso de descongelaci n o para limpiar no use ning n m todo que no...

Страница 19: ...nicio en la caja del enchufe El dispositivo deber serevaluadoenformaperi dica presionandoprimero el bot n TEST Evaluar y luego RESET Reinicio mientrasse encuentreenchufadoaltomacorriente Sielbot nTEST...

Страница 20: ...ntroldeModo HCoolyLCoolbrindanrefrigeraci ncondiferentes velocidadesdelventilador HFanyLFan Losajustesdelventiladorbrindancirculaci n deaireyfiltradosinrefrigeraci n NOTA Simueveelcontroldetemperatura...

Страница 21: ...gue y deje secar el filtro antes de su reemplazo No limpie el filtro en un lavavajillas PRECAUCI N NO utilice el acondicionador de aire sin un filtro ya que la suciedad y las pelusas producir n atasca...

Страница 22: ...cuitos El enchufe de tres p as con conexi n a tierra minimiza la posibilidad de descargas el ctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad...

Страница 23: ...uperior Acondicionador de aire Soporte de Cierre de la Ventana 1 Soportes Laterales 2 PARTES INCLUIDAS La apariencia puede variar Tipo A 3 Junta de gomaespuma de la parte superior de la ventana Marcos...

Страница 24: ...de apoyo deben quedar totalmente aseguradas a alg n metal mamposter a o a la madera El tomacorriente el ctrico debe estar al alcance del cable el ctrico del acondicionador de aire Siga las dimensione...

Страница 25: ...os dos tornillos de madera de 1 provistos Repita este paso del otro lado 4 INSTALL THE AIR CONDITIONER IN THE WINDOW continues D Baje la ventana de modo que el extremo frontal del montaje superior se...

Страница 26: ...struidas de manera similar adjunte el soporte de bloqueo de la ventana a la jamba lateral de la ventana con un tornillo Tipo B B Corte la junta de gomaespuma superior de la ventana del mismo ancho que...

Страница 27: ...guna cortina persiana o mueble bloqueando el frente del acondicionador de aire El control de temperatura no est ajustado apropiadamente En los modelos con botones gire la temperatura a un n mero mayor...

Страница 28: ...o externo de la unidad El ventilador podr a funcionar aun si el compresor no lo hace Las gotitas de agua que caen contra las bobinas externas pueden hacer un ruido de ping Esto ayuda a enfriar el cond...

Страница 29: ...ndar instalacionesdeconexi nel ctricaadecuadas Falladelproductocomoresultadodemodificacionessobre elmismoodebidoaunusoirrazonable incluyendolafaltade mantenimientorazonableonecesario Reemplazodefusibl...

Страница 30: ...service center DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE IMPORTANTE No regrese este producto a la tienda Si tiene un problema con este producto por favor comun quese al 1 877 337 3639 par...

Отзывы: