Indoor Unit Installation
Driver
Torque wrench
(17mm,22mm,26mm)
Nipper
Reamer
Hacksaw
Pipe cutter
Gas leakage detector or
soap-and-water solution
Hole core drill
Flaring tool
Spanner(17,19 and 26mm)
Knife
Measuring tape
Necessary Tools for Installation
Power Source
Before inserting power into receptacle, check the voltage without
fail.
The power supply is the same as the corresponding nameplate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable
can be reached.Do not extend the cable by cutting it.
Selection of Installation Place
Place, robust not causing vibration, where the body can be
supported sufficiently.
Place, not affected by heat or steam generated in the vicinity,
where inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be conne-
cted with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around.
Place where the distance of more than lm from televisions,
radios, wireless apparatuses and fluorescent lamps can be
left.
In the case of fixing the remote controller on a wall, place
where the indoor unit can receive signals when the fluore-
scent lamps in the room are lightened.
The distance between the indoor unit and the floor should be more than 2m.
The models adopt HFC free refrigerant R32
more than
10cm
more than 15cm
more than 10cm
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
Attention must be paid to
the rising up of drain hose
Please be subject to the actual product purchased,the above picture is just for your reference.
If using the left side drain pipe, make sure the hole is got through.
Drawing for the installation of indoor units
5