background image

Operation

 Sleep Operation

If the wind speed is high or middle before setting for the

sleep, set for lowing the wind speed after sleeping.

If it is low wind, no change.

5.Set the wind speed change when sleeping

Operation Mode

1. In COOL,DRY mode

SLEEP operation starts

SLEEP operation stops

SLEEP

operation starts

SLEEP

operation stops

Approx.6hrs

1 hr

1 hr

1 hr

3 hrs

3 hrs

Rises 1

O

C

Rises 1

O

C

Rises 1

O

C

Temp.setting

Temp.setting

Unit stop

Unit stop

In COOL, DRY mode

In HEAT mode

Decreases 2

O

C

Decreases 2

O

C

1 hr

2.

3.

In HEAT mode

In AUTO mode

4. In FAN mode

    It has no SLEEP function.

Note

When TIMER function is set, the sleeping function can’t be 

set up .After the sleeping function is set up

,

TIMER function, the sleeping function will be cancelled; the

machine will be in the state of timing-on.

POWER/QUIET Operation

1 hours after SLEEP mode starts,temp.will become 

higher than temp.setting.After another 1 hours,temp.rises

by 1     futher.The unit will run for further 6 hours then stops

Temp. is higher than temp.setting so that room temperature 

won’t be too low  for your sleep. 

1 hours after SLEEP mode starts,temp will become 2    

lower than temp.setting.After another 1 hours,temp 

decrease by 2

rises by 1     futher.The unit will run for further 3 hours then

stops.Temp.is lower than temp. setting so that room

temperature won’t be too high for your sleep.

The unit operaters in corresponding sleep mode

adapted to the automatically selected operation mode.

O

C

O

C futher.After more another 3 hours,temp.

O

C

1

O

C

O

C

if user resets

Press             button to enter additional options, when 
cycle display to        ,       will flash. And then press
enter to sleep function.

(1)

POWER Operation

(2)

QUIET Operation

Note

When you need rapid heating or cooling, you can use this function. 

You can use this function when silence is needed for rest or reading.

During POWER operation, in rapid HEAT or COOL mode ,  
the room will show inhomogeneous temperature distribution.
Long period QUIET operation will cause effect of not too 
cool or not too warm.

Press QUIET button, the remote controller will show         , 
and then achieve to the quiet function. Press again this 
QUIET button , the quiet function will be cancelled.

Press           button to enter additional options, when cycle 
display to      ,       will flash

and then press         ,enter to 

power function. When cancel the function, please enter 
additional options again and to cancel power function.

3

Press HEALTH  button , the remote controller will show

and then achieve to the health function.

Press again this HEALTH button , the health function will be 

cancelled.   

HEALTH Operation

(This function is unavailable on some models.) 

a lot of anion effectively ba

lance the quantity of position

up the dust sediment in the room and finally clean the

and anion in the air and also to kill bacteria and speed

air in the room.

The anion generato

r

 

in the airconditioner can generate

Содержание Nederlands

Страница 1: ...e reference This appliance is filled with R32 SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL 0010595836 ER AS09FBAHRA AS12FBAHRA AS18FDAHRA AS24FEAHRA Nederlands AS20S2SF2FA AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA AS71S2SF2FA AS25S2SF2FA 1 AS35S2SF2FA 1 AS42S2SF2FA 1 AS50S2SF2FA 1 AS71S2SF2FA 1 AS20S2SF2FA 1 ...

Страница 2: ...contacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage explosion proof breaker must be installed Make sure ground connection is correct and reliable Read the precautions in this manual carefully before operating the unit This appliance is filled with R32 D...

Страница 3: ...9 1 2 8 5 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLATION MAINTENANCE CAUTIONS TROUBLE SHOOTING 10 ...

Страница 4: ...display 16 LOCK button Used to lock buttons and LCD display 25 RESET button When the remote controller appears abnormal use a sharp pointed article to press this button to reset 22 HOUR button Control the lightening and extinguishing of the indoor LED display board 8 9 QUIET button 11 COOL button 10 HEAT button 12 SWING LEFT RIGHT button 13 FAN SPEED button 14 TIMER button 15 HEALTH button 17 LIGH...

Страница 5: ...for the first time and emergency operation starts the unit will run automatically in the following modes Room temperature Designated temperature Timer mode Fan speed Operation mode Above 23 o C Below 23 o C 23 o C 26 o C No AUTO AUTO COOL HEA T No It is impossible to change the settings of temp and fan speed It is also not possible to operate in timer or dry mode temperature is below 16 o C do not...

Страница 6: ... won t be too high for your sleep The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode O C O C futher After more another 3 hours temp O C 1O C O C if user resets Press button to enter additional options when cycle display to will flash And then press enter to sleep function 1 POWER Operation 2 QUIET Operation Note When you need rapid heating or coolin...

Страница 7: ... electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negati...

Страница 8: ... disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space around Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remote controller on a wall place where the indo...

Страница 9: ...hem with the adhesive tape Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor ele...

Страница 10: ...ring e r ror Faulty PCB Faulty EEPROM data Faulty EEPROM Faulty PCB Faulty connector connection Faulty therm istor Faulty PCB Room temperature sensor failure The power source must be exclusively used for air conditioner In the case of installing an air conditioner in a moist place please install an ea For installation in other places use a circuit breaker as far as possible Pipe cutting is carried...

Страница 11: ...ndoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face outside and the white sid...

Страница 12: ...ITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at ...

Страница 13: ...le ambient temperature range Specifications The machine is adaptive in following situation The power plug and connecting cable acquired the local 2 If the power supply cord is damaged it must be replaced manufacturer qualified person 4 The wiring method should be in line with the local wiring 5 After installation the power plug should be easily reached 6 The waste battery should be disposed proper...