manualshive.com logo in svg
background image

For the first use after installation, due to there's no water within the tank, first the city 
water inlet valve and any water outlet valve of the water heater must be opened. Close 
the water outlet valve when water flows out continuously from the showerhead or other 
outlets (the tank is full). Check connections are free of water leakage, and insert the 
power plug. 
Turn the knob to set your desired water heating temperature, which can be stepless 
changed between cold water inlet temperature and 75

. In heating mode, heating lamp 

is lighted on. Normally the knob shall be positioned at highest temperature. This 
machine has a thermostat function, which automatically switches off the water heater 
when temperature reaches the setting value, and switch on again when water 
temperature decreases to certain value.
City water pressure 

0.75 MPa will cause much water flowing out from safety valve 

pressure relief vent. This is due to too big water pressure. Please ask after-sales 
service for correction.

To avoid causing machine troubles, do not connect power before tank is full of water. 
Adjust a suitable temperature before use, for water temperature above 50

 may burn  

your skin.
This product is closed water heater, which can supply hot water through pipe connection 
to several points like bathroom (bathtub, washbasin, showerhead) and kitchen. 
Heating adjustment can be made flexibly all year round adapting to climate changes. In 
long-term out-of-use or maintenance, you can close city water pipe valve, open mixing 
valve, and move up safety valve handle to drain the tank. To avoid injury, before next use, 
it is suggested to first open hot water valve before switching on the water heater, 
exhausting gas possibly retained in the pipeline. In this case, no smoke or fire is 
permitted near the open valve. Carefully check and confirm all parts are in good 
condition.
Provided hot water quantity can meet use demand, temperature setting shall be possibly 
low. It can minimize heat dissipation, high-temperature corrosion and sedimentation, 
ensuring a longer service life. 
Regularly ask servicemen to make safety inspection, remove sediment on heating 
elements, and check consumption of anode bar. Too much consumed anode bar shall be 
replaced. 

This water heater shall only be repaired and maintained by qualified 
servicemen. Improper maintenance may cause severe injury or damage. 
Before opening or repairing water heater, please do pull out the power plug.

External Cleaning: Disconnect power supply before cleaning. Gently wipe with wet 
cloth dipped with a little of mild detergent. Do not use gasoline or other solvents. 
Finally dry with dry cloth. Keep water heater dry. Do not use cleansers containing 
grinding agent (e.g. toothpaste), acids, chemical solvents (e.g. alcohol) or polishers to 
clean.

L

N

E

HL

EH

E

BT

MT

L: Brown wire
N: Blue wire
MT:High temperature limiter
BT:  Thermostat
HL: Heating indicator
EH: Heating element
E:Yellow/green wire

(Fig. 1)

1.

2.

3.

4.

5.

6.

Statement: 

Note:  Before asking for service, please refer to troubleshooting section to resolve easy 

problems.

Remarks:the permitted error limit of above parameters is 

 10%.

Hot water outlet

Cold water inlet

Heating element

Enamel tank

Wall-mounting bracket

Front View

Cutaway View  

Bottom View

D

E

E

C

a1

e1

C1

d1

b1

A

B

Dimensions

Electric Circuit Diagram

Operation Instructions

Attentions in Operation

Cleaning and Maintenance

Model

Volume

  

Net

     Weight

a1

b1

c1

d1

e1

f1

f1

Отзывы: