background image

Little Sea-ox

Haier Household Electric Water Heater

User's Manual

Please read this manual before usage

Retain it for future reference

     

HAIER

THERMOCOOL

FCD

JTHA30-

ET

FCD

JTHA40-

ET

FCD

JTHA50-

ET

FCD

JTHA60-

ET

FCD

JTHA80-

ET

Haier Garden, Qianwangang Road, Economic Development
Zone,Qingdao,  P. R. China

            

Group

 

Qingdao Economic and Technological Development 

 District Haier Water Heater Co., Ltd.

Содержание LITTLE SEA-OX FCD JTHA30- ET

Страница 1: ...before usage Retain it for future reference HAIER THERMOCOOL FCD JTHA30 ET FCD JTHA40 ET FCD JTHA50 ET FCD JTHA60 ET FCD JTHA80 ET Haier Garden Qianwangang Road Economic Development Zone Qingdao P R China Group Qingdao Economic and Technological Development District Haier Water Heater Co Ltd ...

Страница 2: ...whether your house ground wire is live or not all the time If this mark is lighted on it indicates your house ground wire has come live poor grounding and live In this case please immediately stop use and unplug from the power supply and remember not to touch any electric appliance shell in your house At the same time immediately contact after sales service and your property management company for...

Страница 3: ...ll be cleaned once in three years Take care not to damage protection layer on heating elements and tank liner inner surface According to different local water qualities and use habits magnesium rod shall be periodically replaced If maintenance is needed please contact local service station FAQ Phenomenon Confirmation items Remedy Check Check and clear Check and open Check power socket Keep heating...

Страница 4: ...pressure 0 75 MPa will cause much water flowing out from safety valve pressure relief vent This is due to too high water pressure Please ask after sales service for correction Operation Instructions To avoid causing machine troubles do not connect power before tank is full of water Adjust a suitable temperature before use for water temperature above 50 may burn your skin This product is closed wat...

Страница 5: ...wires are in accordance with the rated current of the water heater If necessary please have it checked by experienced electrician The water heater adopts power supply of 220 240V 50 60Hz Be sure to use independent receptacle and earth it reliably The receptacle shall comply with the stipulation of national standard The product adopts the patent Safe Care technology of our company As long as adopti...

Страница 6: ...nded as necessary The hose shall be installed as inclined downward see to Figure 4 Figure 3 for reference in installation only Cold water inlet Mixing valve Hot water outlet valve Cold water outlet valve Shower head Hot water outlet Safety valve Installation must be made by installers of or designated by our company after service department The water heatershall be wall mounted Before installation...

Отзывы: