Error message. Water level exceeds protective value.
Troubleshooting:
N
Check if water switch hose and air collector
are jammed
Clean water switch hose and air
collector
N
Pull out water switch inserts and turn on
power, then set wash mode. While water
is entering at the position of 1/4 glass
window, check the resistance between
ķ
and
ĸ
, is it 0? Check the resistance
between
ķ
and
Ĺ
, is it infinite?
Replace water pressure switch
Y
Y
Without starting but electrifying, measure the
import voltage of inlet valve, is it between
AC 220-240V?
Replace
PCB
Y
N
Replace inlet valve
Without power ,connect inlet pipe to inlet
vavle,then open the tap and observe if water
is entering in dispenser
Y
Troubleshooting:
Replace it
N
Y
N
Connect
well
Y
Replace display board
Check if
the dry temperature sensor
is connected properly
it
Check if
the dry temperature sensor
is short cut or open
Error message:
The dry temperature sensor short cut or open.