Error message:Door is not properly shut 20s after program is started.
Troubleshooting:
N
Y
Pushing the door to Check Whether Door
is properly shut or not
Y
Door lock is
broken and
need
replacing,then make sure wire is
connected properly.
Check the voltage between gray wire and
red wire of power driver PCB, is it
between AC 220-240V?
Cut off the power and then turn on
again.Check the voltage between brown
wire and blue wire of door lock, is it
between AC 220-240V?
N
N
Power driver
PCB
220-240V
Y
N
Check if the wire connecting door lock
Connect
the wire
properly
SERVICE MANUL
HWD-C1200TXVE-U
Haier Washing Machine
Shut the door properly
Chapter 6
Troubleshooting and Maintenance
Check if water is emptied Y
Check if water level pressure switch is undamaged
N
Check if drain pump acts by touching
Check if drain pump or
pump position
Y drain pipe is jammed,and
open the filter and clean
N
Cut off the power and choose spin program to
start,then check the import voltage of drain
pump,is it between AC 220V?
Y Replace drain pump
N
Cut off power and pull out water level
pressure switch wire connection .Set spin
The wire between display
program to start. Check the export voltage to Y
board and drain pump is not
drain pump ,is it between AC 220V?
connected properly.
Replace the wire
N
Replace display board
Содержание HWD-C1200TXVE-U
Страница 8: ...SERVICE MANUL HWD C1200TXVE U Haier Washing Machine Chapter 2 Matters needing attention ...
Страница 9: ...SERVICE MANUL HWD C1200TXVE U Haier Washing Machine ...
Страница 10: ...SERVICE MANUL HWD C1200TXVE U Haier Washing Machine ...
Страница 12: ...SERVICE MANUL HWD C1200TXVE U Haier Washing Machine ...
Страница 16: ...Control Panel SERVICE MANUL HWD C1200TXVE U Haier Washing Machine ...