HSU12
HG(DB)-SM
Service Diagnosis
60
Domestic Air Conditioner
˄
A
˅
YES
NO
Yes
Check the indoor mainboard.
No
If the voltage is of a constant
value of 0V DCto5V DC
YES
Measure the voltage between Jumpers 3 and
4 of IC1 on the indoor mainboard with a
multimeter.
The outdoor mainboard is damaged;
Replace them with a new one.
Measure the AC voltage between
positions 1 and 3 on the terminal of
outdoor unit with a multimeter.
If 230VAC is available but 310DC not,
the power module is damaged, replace it
with a new one.
Test the outdoor power supply (230VAC
and +310VDC) with a multimeter.
The outdoor mainboard is damaged; replace
it with a new one.
The indoor mainboard is damaged; replace
it with a new one.
If the value varies between 0 and 80 VAC, the
outdoor mainboard is damaged, replace it
with a new one.
If the value is constant at about 30V, the
indoor mainboard is damaged, replace it with
a new one.
If both 230VAC and 310DC are
available, measure
+12V(from7805) is available.
No
Содержание HSU12VHG-B
Страница 16: ...HSU12 HG DB SM Connector Wring Diagram 13 Domestic Air Conditioner PCB 2 CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN11 CN10 ...
Страница 43: ...Domestic Air Conditioner HSU12 HG DB SM System Configuration 40 ...
Страница 71: ...68 Domestic air conditioner Removal of procedure 9 1 HSU12 HG DB SM ...
Страница 74: ...71 Domestic air conditioner Removal of procedure three two HOOKS HSU12 HG DB SM ...
Страница 75: ...72 Domestic air conditioner Removal of procedure horizontal flap flap flap flap flap 9 3 HSU12 HG DB SM ...
Страница 76: ...73 Domestic Air Conditioner Removal of procedure 9 4 HSU12 HG DB SM ...
Страница 77: ...74 Removal of procedure 9 5 HSU12 HG DB SM Domestic Air Conditioner ...
Страница 78: ...75 Domestic air conditioner Removal of procedure 9 6 HSU12 HG DB SM ...
Страница 79: ...76 Domestic air conditioner Removal of procedure 9 7 HSU12 HG DB SM ...
Страница 80: ...Domestic air conditioner 77 Removal of procedure HSU12 HG DB SM ...
Страница 81: ...Domestic air conditioner Removal of procedure 78 HSU12 HG DB SM ...
Страница 82: ...79 Domestic air conditioner Removal of procedure HSU12 HG DB SM ...
Страница 83: ...80 Removal Procedure 9 HSU12 HG DB SM ...
Страница 84: ...81 Removal Procedure HSU12 HG DB SM ...
Страница 85: ...Removal Procedure 82 4 HSU12 HG DB SM ...
Страница 86: ...83 Removal Procedure HSU12 HG DB SM 9 10 ...
Страница 87: ...84 Removal Procedure 11 HSU12 HG DB SM ...
Страница 88: ...85 Removal Procedure 12 HSU12 HG DB SM ...
Страница 89: ...86 Removal Procedure HSU12 HG DB SM ...
Страница 90: ...87 Removal Procedure HSU12 HG DB SM 9 13 ...
Страница 91: ...88 Removal Procedure HSU12 HG DB SM ...
Страница 98: ...Wu Hongjin Shi Longfei Yu Huali Wang Fei 86 532 88936935 The end Sincere Forever Haier Group HSU12 HG DB SM ...