background image

Outdoor unit

5.Purging Method:

7

3-way valve

2-way valve

6.35mm(1/4")

12.7mm(1/2")

HSU-12CRA03-T

HSU-09CRA03-T

3-way valve

2-way valve

6.35mm(1/4")

9.52mm(3/8")

3-way valve

12.7mm(

1

/

2

")

2-way valve

6.35mm(

1

/

4

")

HSU-18CRA03-T

Note: When extending piping, air inside piping shall be removed  by using external refrigerant gas, 

charge according to the following list.

Brand new outdoor unit is charged 50g more refrigerant than regulated weight. Only for 

first installation, this extra 50g can be used to purge airin pipes.
          During this procedure, 50g refrigerant will be discharged in piping.(This must be
          strictly controlled within 90

o

 and 10 sec.)

When connecting pipe exceeds 5 meters, 20g 

refrigerant shall be added per exceeding meter. 

Charge according to the following list. 

Piping length

Additional amount

5m

7m

No need

40g

10m

100g

for   9k 12k 18k

Push the air out of the indoor unit

and piping as followes:
(1) Remove the valve cap on 2-way valve in outdoor unit.

(2) Loosen by 1/2 turn the flare nut of gas pipe, which is

is conneted to 3-way valve.

(3) Loosen 2-way valve by 90

o

 using hexagon wrench, 

and after approx.10 sec tighten it up. Gas comes out

     through flare nut on wide pipe. If no gas is discharged,

tighten flare nut with specified torque.

(4) Open 2-way and 3-way valves using specified torque.

(5) Tighten the caps on the valves with specified torque.

Valve rod

Valve cap

7-9

20-25

Tighten torque N.m

for   9K 12K:B= 5m

for 18K : B=10m

Max. Length:       for 9K

: A=7m

                            for 12K           : A=10m

m

0

2

=

A

:

K

8

1

r

o

f

Max.Elevation:

C

Outdoor unit

Indoor unit

Outdoor unit

Indoor unit

Oil trap

A

B

Outdoor unit

Indoor unit

A

B

A

B

CAUTION

In case more than 5 metres

oil trap

should be installed every 5~7m.

C

Содержание HSU-18CRA03-T

Страница 1: ...Drain hose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance betw...

Страница 2: ...ptacle with enough space around Refer to drawings Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remo...

Страница 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Страница 4: ...ody aslant from the underside and then put it down perpendicularly 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from bac...

Страница 5: ...h the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defe...

Страница 6: ...wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installat...

Страница 7: ...ing to the following list Piping length Additional amount 5m 7m No need 40g 10m 100g for 9k 12k 18k Push the air out of the indoor unit and piping as followes 1 Remove the valve cap on 2 way valve in...

Страница 8: ...pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly expla...

Отзывы: