background image

     Do not obstruct or cover the ventilation
grille of the air conditoner.Do not put fingers
or any other things into the inlet/outlet and
swing louver.

     Do not allow children to play with the air
 conditioner.In no case should children be
allowed to sit on the outdoor unit.

 The refrigerating circuit is leak-proof.

1.Applicable ambient temperature range:

Cooling

Indoor

Maximum:D.B/W.B

Maximum:D.B/W.B
Maximum:D.B

Maximum:D.B
Maximum:D.B

Minimum:D.B/W.B

Maximum:D.B/W.B

Minimum:D.B/W.B

Outdoor

Indoor

Outdoor

Heating

 Specifications

 

The machine is adaptive in following

 situation

10 .The power plug and connecting cable
      must have acquired the local attestation.

2. If the power supply cord is damaged, it
   must be replaced by the manufacturer
   or its service agent or a similar qualified
   person.

4. The wiring method should be in line with
   the local wiring standard.

5. After installation, the power plug should
   be easily reached.

6. The waste battery should be disposed
   properly.

7. The appliance is not intended for use
    by young children or infirm persons
    without supervision.

8. Young children should be supervised
    to ensure that they do not play with
    the applience.

9.Please employ the proper power plug,
   which fit into the power supply cord.

Cautions

32

o

C/23

o

C

24

o

C/18

o

C

-7

o

C/-8

o

C

43

o

C/26

o

C

18

o

C

27

o

C

15

o

C

18

o

C/14

o

C

2

Outdoor

Maximum:D.B/W.B

Minimum:D.B/W.B

24

o

C/18

o

C

-15

o

C

(INVERTER)

3. If the fuse of indoor unit on PC board is
   broken,please change it with the type of
   T. 3.15A/ 250V. If the fuse of outdoor
   unit is broken,change it with the type of
   T.25A/250V

Содержание HSU-09RC03/R2(DB)

Страница 1: ...Please read this operation manual before using the air conditioner HSU 09RC03 R2 DB HSU 12RC03 R2 DB HSU 18RC03 R2 DB HSU 22RC03 R2 DB SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL...

Страница 2: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Страница 3: ...cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 4 The wiring method should be in line with the local wiring standard 5 After installation the...

Страница 4: ...ease call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a inadequ...

Страница 5: ...ially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occ...

Страница 6: ...etgrille AirPurifyingFilter inside Anion generator inside Vertical louver Use remote controller to adjust up and down air flow Don t adjust it manually Horizontal louver Air filter inside Outlet Power...

Страница 7: ...on and extinguished 31 CODE Used to select CODE A or B with a press A or B will be displayed on LCD Please select A without special explanation 1 HEALTH button Used to set healthy operation 2 HOUR but...

Страница 8: ...y obstacle as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the rec...

Страница 9: ...rk the health lamp lights up but the anion generator does not release anion Operation Health Operation Remote controller 1 Unit start Then set up the comfortable working state Link with electronic pow...

Страница 10: ...pt Timer Sleep Power Soft and Health airflow 2 Select operation mode Press FAN button For each press fan speed changes as follows Press MODE button For each press operation mode changes as follows Rem...

Страница 11: ...ler Remote controller Then Select COOL operation Press TEMP button Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly Every time the button is presse...

Страница 12: ...ncrease 1 C if kept depressed it will increase rapidly Every time the button is pressed temp setting increase 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed se...

Страница 13: ...fan speed changes as follows Press MODE button For each press operation mode changes as follows Remote controller Remote controller Then Select FAN operation 3 Fan speed selection 4 Unit stop About F...

Страница 14: ...TEMP button Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly Every time the button is pressed temp setting increase 1 C if kept depressed it will...

Страница 15: ...ent operation modes remote controller COOL DRY FAN remote controller remote controller The vertical flap will swing according to the above positions HEAT AUTO Horizontal louvers Pos 1 Pos 2 Pos 3 Pos...

Страница 16: ...creases 2O C Decreases 2O C 1 hr Sleep Operation 2 3 In HEAT mode 1 hours after SLEEP mode starts temp will become 2 O C lower than temp setting After another 1 hours temp decrease by 2 O C further Af...

Страница 17: ...as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every time the button is pr...

Страница 18: ...HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidl Every time the button is pressed time setting decreases 1 min if kept depressed it...

Страница 19: ...SOFT button twice POWER SOFT disappears In SOFT operation mode fan speed automatically takes LOW changes as follows Stop the display at SOFT BLANK POWER Press POWER SOFT button Every time the button i...

Страница 20: ...flow blows direct to the body Note 1 After setting the health airflow function the position of in and outlet grills is fixed 2 In heating it is better to select the mode 3 In cooling it is better to s...

Страница 21: ...operation the system automatically selects the operation modes cooling or heating according to the room temperature Test operation Test operation switch is the same as emergency switch Use this switch...

Страница 22: ...eration prevent the penetration of direct sunlight with curtain or blind Close doors and windows during operation If the unit is not to be used for a long time turn off the power supply main switch OF...

Страница 23: ...at the filter is completely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use...

Страница 24: ...g intermediary accessories with machine will be used based on real situation The bacteria killing medium air purifying filter is available for a long time and needn t to be changed But it must be noti...

Страница 25: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Страница 26: ...g insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may cause t...

Страница 27: ...ve elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a sw...

Отзывы: