background image

Operation

 Sleep Operation

Use of SLEEP function

Operation Mode
1. In COOL,DRY mode

SLEEP operation starts

SLEEP operation stops

SLEEP
operation starts

SLEEP
operation stops

Approx.6hrs

1 hr

1 hr

1 hr

3 hrs

3 hrs

Rises 1

O

C

Rises 1

O

C

Rises 1

O

C

Temp.setting

Temp.setting

Unit stop

Unit stop

In COOL, DRY mode

In HEAT mode

Decreases 2

O

C

Decreases 2

O

C

1 hr

2.

3.

In HEAT mode

In AUTO mode

4. In FAN mode

It has no SLEEP function.

POWER/SOFT Operation

Before going to bed,you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring
you a sound sleep. 

After the unit starts,set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.

1 hours after SLEEP mode starts,temp.will become 
1     higher than temp.setting.After another 1 hours,
temp.rises by 1     futher.The unit will run for further 
6 hours then stops Temp. is higher than temp. 
setting so that room temperature won’t be too low 
for your sleep. 

1 hours after SLEEP mode starts,temp will
become 2     lower than temp.setting.After
another 1 hours,temp decrease by 2
futher.After more another 3hours,temp.rises
by 1     futher.The unit will run for further 3
hours then stops.Temp.is lower than temp.
setting so that room temperature won’t be 
too high for your sleep.

The unit operaters in corresponding sleep mode
adapted to the automatically selected operation
mode.

O

C

O

C

O

C

O

C

O

C

4

Power Failure Resume Function

When TIMER function is set , the quiet sleeping 
function can't be set up. After the sleeping function 
is set up, if user resets TIMER function, the sleeping 
function will be cancelled; the machine will be in the
state of timing-on, if the two modes are set up at the 
same time, either of their operation time is ended
first, the unit will stop automatically, and the other 
mode will be cancelled. 

When quiet sleeping function is set to 8 hours,

the quiet sleeping time can not be adjusted.

5.

1. If the unit is started for the first time, the compressor 
will not start running unless 3 minutes have elapsed.
When the power resumes after power failure, the unit will 
run automatically, and 3 minutes later the compressor
starts running.

2. Note to the power failure resume:
press the sleep button ten times in five seconds and enter 
this function after hearing four sounds. And press the sleep 
button ten times within five seconds and leave this function 
after hearing two sounds.

(1)

POWER Operation

(2)

SOFT Operation

When you need rapid heating or cooling, you can use this function.
In COOL mode, fan speed automatically takes high speed of 
AUTO fan mode. In HEAT mode, fan speed automatically takes 
medium speed of AUTO fan mode.

You can use this function when silence is needed for rest or reading.
In SOFT operation mode, fan speed 

automatically takes low speed 

of AUTO fan mode.

Note

˖

During POWER operation, in rapid HEAT or COOL mode

the room 

will show uniform temperature distribution. Long period
SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again, POWER or SOFT  disappears.

Содержание HSM24HEK03

Страница 1: ...AUTIONS Contents 1 9 10 13 14 ndice PRECAUCIONES COMPONENTES Y FUNCIONES FUNCIONAMIENTO MANTENIMIENTO RESOLUCI N DE PROBLEMAS 1 16 17 20 21 Contenuti AVVERTENZE PARTI E FUNZIONI FUNZIONAMENTO MANUTENZ...

Страница 2: ...reference Please be subject to the actual produce purchased the above picture is just from your reference Air Purifying Filter inside Inlet 1 Inlet grille 2 Outlet 3 adjust left and right air flow Ve...

Страница 3: ...peration air conditioner will automatically select Cool or Heat operation according to room temperature to AUTO the air conditioner automatically adjusts temperature When FAN is set the fan speed acco...

Страница 4: ...hen TIMER function is set the quiet sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in...

Страница 5: ...the system yourself the dismantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS 1 1 2 kg R410A 2 kg 2 1 B C D F E kg A This product contains fluorinated greenhouse gases covered by the...

Страница 6: ...e water out of the cloth before wiping then wipe off the detergent completely Air Filter cleaning Open the inlet grille by pulling it upward Remove the filter Clean the filter Attach the filter Close...

Страница 7: ...BITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or...

Страница 8: ...3 minutes to protect the air conditioner immediately until 3 minutes have Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type...

Страница 9: ...O DE SE AL 14 Indicador de TEMPORIZADOR DE APAGADO 15 Indicador de TEMPORIZADOR DE ENCENDIDO 16 Indicador de RELOJ 17 Indicador de la funci n SUE O 18 Bot n ENCENDIDO APAGADO 19 Bot n OSCILACI N 20 B...

Страница 10: ...ento de prueba Ajuste de la direcci n del ujo de aire 1 Indicador de estado de env o de aire Aler n vertical Pos 1 Desactivado Pos 2 Pos 3 Pos 4 Oscilaci n autom tica 2 Ajuste del ujo de aire hacia la...

Страница 11: ...te y se cancelar el otro modo Funci n de reanudaci n tras fallos en el suministro el ctrico 1 Si es la primera vez que se arranca la unidad el compresor no se pondr en marcha a menos que hayan transcu...

Страница 12: ...TEMPORIZADOR DE APAGADO TEMPORIZADOR DE ENCENDIDO APAGADO DESACTIVADO REQUISITOS DE ELIMINACI N Su aparato de aire acondicionado ha sido marcado con este s mbolo el cual indica que los productos de t...

Страница 13: ...n agua Escurra el agua del pa o antes de pasarlo sobre la unidad A continuaci n elimine por completo todos los restos de detergente No utilice ninguno de los siguientes productos para limpiar la unida...

Страница 14: ...e el cable de la fuente de alimentaci n PROHIBIDO Extreme la precauci n para evitar da ar el cable de la fuente de alimentaci n PROHIBIDO No inserte objetos a trav s de la toma de entrada o salida de...

Страница 15: ...emperatura correctamente Existen puertas o ventanas abiertas Penetra la luz solar directamente a trav s de las ventanas durante el funcionamiento en modo de refrigeraci n Utilice cortinas Existen dema...

Страница 16: ...Temperatura 13 INVIO DEL SEGNALE 14 Icona Timer spegnimento 15 Icona Timero accensione 16 Icona Orologio 17 Icona Sospensione 18 Tasto Accensione spegnimento 19 Tasto Oscilla 20 Tasto Ora Accensione S...

Страница 17: ...a il funzionamento sospensione non disponibile Funzionamento di emergenza e test Regolazione della direzione del usso d aria 1 Visualizzazione dello stato dell aria inviata Aletta verticale Pos 1 vuot...

Страница 18: ...poraneamente in base al tempo di operativit che termina prima l unit si spegner automaticamente e l altra modalit verr annullata Funzione di recupero da black out 1 Quando l unit viene avviata per la...

Страница 19: ...gnimento VUOTO REQUISITI PER LO SMALTIMENTO Il condizionatore acquistato contrassegnato con questo simbolo che sta ad indicare che le parti elettriche ed elettroniche non devono essere mischiate con i...

Страница 20: ...prima di passarlo quindi togliere completamente il detergente Per la pulizia non usare quanto segue Benzina diluenti o soluzioni detergenti possono danneggiare il rivestimento dell unit Acqua calda o...

Страница 21: ...i alimentazione DIVIETO Non inserire oggetti nell ingresso o nello scarico dell aria DIVIETO Non avviare o arrestare l unit scollegando il cavo di alimentazione ecc DIVIETO Non dirigere il usso dell a...

Страница 22: ...15 giorni La presa e l uscita d aria sono ostruite La temperatura impostata correttamente Ci sono porte o nestre aperte La luce del sole entra direttamente nella stanza mentre in funzione il condizion...

Страница 23: ...hage MINUTERIE EN MARCHE 16 Af chage HORLOGE 17 Af chage SOMMEIL 18 Bouton MARCHE ARR T 19 Bouton POSITION 20 Bouton ALIMENTATION HEURE DOUX Utilis pour pour r gler l heure et le minuteur Appuyez sur...

Страница 24: ...ATEUR le mode SOMMEIL n est pas disponible Fonction d urgence et test R glage de l orientation du ux d air 1 Af chage de l tat d envoi d air Volet vertical Pos 1 vide Pos 2 Pos 3 Pos 4 Position auto 2...

Страница 25: ...temps de fonctionnement se terminera en premier provoquera l arr t de l appareil et l annulation de l autre mode Fonction Reprise apr s panne de courant 1 Si l appareil est d marr pour la premi re fo...

Страница 26: ...appareil de climatisation est marqu de ce symbole Ceci signi e que les produits lectriques et lectroniques ne doivent pas tre m l s aux d chets m nagers non tri s Ne pas tenter de d monter le syst me...

Страница 27: ...dans de l eau Essorer le chiffon avant de nettoyer puis totalement ter le d tergent Ne pas nettoyer avec les produits suivants essence benzine dliluant ou poudre nettoyer pouvant endommager l enduit d...

Страница 28: ...ique INTERDICTION Ne pas ins rer d objets dans l entr e ou la sortie d air INTERDICTION Ne pas d marrer ou arr ter le fonctionnement en d connectant le cordon d alimentation INTERDICTION Ne pas dirige...

Страница 29: ...l un obstacle devant l entr e et la sortie d air La temp rature est elle correctement r gl e Des portes ou des fen tres sont elles ouvertes Existe t il un ensoleillement direct venant d une fen tre du...

Отзывы: