Chapter 8 Trouble shooting 

8-1. Common problems and solutions 

8-1-1 Symptom: the buzzer beeps to alarm 

1) Test across pin 10 and pin 12 of CN1 on the main control panel. The 2 pins should be switched to 
conduction when the door is closed and disconnected when the door is open. 
2) If pin 10 and pin 12 of CN1 are disconnected in both cases, please remove the front decoration strip 
to see if the door switch is still in the slot and direction of installation. 

8-1-2 Symptom: neither displaying nor starting when powering on 

Check: 

1) Check if the power supply is connected properly. 
2) Remove the main control panel and examine its back side carefully to see if there are solder skips or 
open soldering; 
3) Check if the connector of the refrigerator hinge is connected properly. 
4) Verify the display panel to see if it is in OFF state. If so, please press key C on the display panel for 
5 seconds to turn it on. 

Solutions: 

1) If there is dry soldering or open soldering on the control panel, change it with an electrical iron. 
2) If any connector is not connected properly, replug it firmly. 
3) Press and hold the button on the display panel for 5s to turn the refrigerator on. 

8-1-4 Symptom: poor cooling effect accompanied by loud noise 

Check: 

1) Check if there is obvious abnormal sound.   

Set the control panel on  “T1”  mode (refrer 4-3), and check if the cooling fan is operating normally. 

2) If the cooling fan does not run, remove it and check if its connector and the cabinet connector are 
connected properly. Test if there is approximately 12VDC voltage across pin 9 and pin10 of CN3. If 
there is no 12VDC voltage, the main control panel can generally be determined to be malfunctioning. 
If there is 12VDC voltage, the refrigerator fan can generally be determined to be malfunctioning. 
3) If the fan rotates abnormally, the fan is malfunctioning. 

Solutions: 

1

If there is apparent abnormal sound in the compartment, check if the fan is firmly fixed.   

If any of these problems is found, please remove the fan and reinstall it properly. 

2

If the fan connector is not installed properly, disconnect the terminals and reinstall the connector

。 

3

If the main control panel or the fan is malfunctioning, replace it 

8-2 Examination and Solutions for Other Problems 

Problems 

Causes 

Solutions 

Water/moisture/frost in the freezer 
Moisture accumulates 

on the freezer inner 

walls 

z

  Hot and moist climate.

z

  The door is not closed 

tightly 

z

  The door is opened too 

frequently or for too long 

time 

z

Accumulation  of  frost  and  moisture 

accelerate in such climate. 

z

  Make sure the freezer is level and there is 

no  food  or  container  interfering  with  the 

door 

z

  Do not open the door so frequently 

Water/moisture/frost on outside surface of the freezer

Содержание HRF328W2

Страница 1: ...ly and is not designed for use by the general public It dose not contain warnings and cautions to advice non technical individuals of potential dangers in attempting to service a product Product power...

Страница 2: ...embly Door hinge hinge cover 12 4 2 Control panel assembly Panel cover board knob indicator light 12 5 Control and display system 13 5 1 Control and display panel 13 5 2 Start up 13 5 3 Error code dis...

Страница 3: ...oid potential electrical shock 4 Confirm the rated current voltage and capacity before testing with any kinds of instruments 5 Watch if the upper door is open when you check something at a lower posit...

Страница 4: ...ent damage to the compressor caused by continuous restart Photo used in this manual The illustration and photos used in this Manual may not base on the final design of products which may differ from y...

Страница 5: ...class SN 10 32 C N 16 32 C ST 18 38 C T 18 43 C SN T SN T Freezer compartment star rating Gross capacity l 331 361 Total net capacity l 328 358 Net capacity refrigerator compartment l 328 358 Net cap...

Страница 6: ...e from to C 2 8 2 8 Super Cooling Fridge Super Freezing Freezer Stand by function Holidays ECO function Over temperature alarm Red lamp LCD LED Acoustic Acoustic Acoustic Adjustable thermostat Control...

Страница 7: ...older bottle s n n 1 5 1 5 Chiller compartment drawer 0 1 Crisper s Number colour t transparent w white n 1 t 1 t Shelf on salad crisper g glass p plastic p p Door Storage rack s Total n n 4 4 Butter...

Страница 8: ...180 175 180 Condenser External External 9 Packing dimensions loadability Packing dimensions H W D cm 172 6 65 73 5 192 65 73 5 Gross weight kg 71 0 82 0 40 Container load pcs 54 54 40 HC Container loa...

Страница 9: ...SERVICE MANUAL Model HRF328 368 9 Issue 2015 7 18 Rev Ref 1507S002V1 2 External views...

Страница 10: ...he sealed system 4 If refrigerator is tilted let it stand in an upright position for at least 24 hours prior to plugging This is to allow the refrigerant to settle 5 Proper Air Circulation To assure t...

Страница 11: ...hing detergent Dry and polish with a clean soft cloth Do not wipe the refrigerator with a soiled dishwashing cloth or wet towel Do not use scouring pads powdered cleaners bleach or cleaners containing...

Страница 12: ...1507S002V1 Chapter 4 Disassembly 4 1 Door assembly Door hinge hinge cover 4 2 Control panel assembly Install it according to the reverse step Demount the display panel assembly with the cupule Unplug...

Страница 13: ...5 1 Control and display panel 5 2 Start up Start up 1 Insert the plug in the socket to switch on the refrigerator 2 Display will show you the actual temperature When Display show H it means that the a...

Страница 14: ...or example after the purchase or if you want to cool drinks quickly The Super cooling function accelerates the cooling of fresh food and protects the goods already stored from undesirable warming The...

Страница 15: ...nomalous condition will be notified by intermittent buzzer The alarm condition will stop by closing the door or by pressing key B to select Alarm function and pressing the key C but in this second cas...

Страница 16: ...panel connector is in good condition 3 Check whether the connector CN2 of main control PCB is installed position 4 Test if each wires of CN2 connecting to display panel are conduction 5 4 Self Test Te...

Страница 17: ...sor is malfunction short circuit or open circuit the display panel will display error code F1 after Show of error code operation Chapter 6 System flow principle 6 1 Refrigeration flow chart The refrig...

Страница 18: ...SERVICE MANUAL Model HRF328 368 18 Issue 2015 7 18 Rev Ref 1507S002V1 6 2 Refrigeration flow scenograph...

Страница 19: ...7 Circuit diagram 7 1 Brief principle diagram 7 2 Wiring diagram and main control board assembly 7 2 1 Wiring diagram Before2015 05 01 After2015 05 01 Change part The power board 0071800082 connector...

Страница 20: ...riginal parts only may be used in early production sets New parts may be used in late production sets only Stock original and new parts 8 Comply whit ROHS New Service Bulletin No Notice e g ASSBCDW060...

Страница 21: ...to 20 30 5 6 Connected to the refrigerator temperature sensor We can test the sensor with these two white wires Resistance test is the same as the defrosting temperature sensor 7 9 Null 10 Door switch...

Страница 22: ...noise Check 1 Check if there is obvious abnormal sound Set the control panel on T1 mode refrer 4 3 and check if the cooling fan is operating normally 2 If the cooling fan does not run remove it and ch...

Страница 23: ...for the freezer to totally cool down z Warm air enters the freezer and causes it to start frequently Please do not open the door so frequently z Make sure the freezer is level place and there is no f...

Страница 24: ...t should not have noise if it has means the starter Magnetic Disk burned YES Check if the overload protector is normal 1 Measure whether two ends of overload protector is through using multimeter Ohm...

Страница 25: ...ach connectors of the starter overload protector and run capacitor ensure each contact is in good condition then power on and retest the machine YES Check if the compressor is normal Test the resistan...

Страница 26: ...SERVICE MANUAL Model HRF328 368 26 Issue 2015 7 18 Rev Ref 1507S002V1 8 3 2 Poor cooling...

Страница 27: ...SERVICE MANUAL Model HRF328 368 27 Issue 2015 7 18 Rev Ref 1507S002V1 Sincere forever Haier Group Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com...