27
Remedy
Check the whole machine , particularly those locations which are liable
to leak .After leak points have been found ,repair them or replace them with
new parts according to specific circumstances ,then evacuate the system
and finally charge refrigerant.
2) Refrigerating system has been clogged
a) Clogged with Ice
Analysis of Trouble
The dryness
treatment
for
the
major
parts
in
the
refrigerating system
has been
performed
improperly,
the
effect
of
air
purging
for
the whole
system is
not
good
,or
the
water
content
in
the
refrigerant
is out of
standard
,all
these
will
cause
the
expansion
valve
to
be
clogged with
ice .The
symptom
for
this
trouble
are
as
follows
: the
refrigerator
sometimes
can refrigerate
and
sometimes
cannot
:the
refrigerator
compartment works
normally
at
the
beginning
,but
after
working
for
a
certain
period of
time ,frosting
begins
at
the
clogged
position
,evaporation
temperature
reaches
below
o
0 C
,
water
will
accumulate
at
the
narrow
part
of
the capillary
and clog
it
gradually
,then
frost
begins
to
melt
at
the
evaporator
,no gas
flowing sound
can
be
heard
,and
the
gas
suction
pressure
assumes a state
of vacuum
.Note
that
these
phenomena
will
appear
intermittently ;
sometimes
,the
refrigerator
works
well
,and
sometimes
not
well
.In
order to
determine
whether it
is
clogged
with
ice
,heat
the suspicious
points
with hot
water to
make
ice
melt
,and
after
a
while
if
a
gas
flowing
sound
resulting
from an
abrupt
gush
is
heard
and
the
gas
suction
pressure
rises
as well ,it
can be confirmed that the trouble is
caused
by ice clogging
.
Remedy
If there
is
too
much
moisture
in
the
refrigerating
system,
it
is
advisable
to release
the
refrigerant,
purge
the
tubing
with
nitrogen,
and
then charge
the system
with
the
filtered
refrigerant.
However,
the
commonly
adopted
method
is
to
connect
a
filter
with
moisture
absorbers
(such
as
silica-gel,
anhydrous
calcium
chloride)
to
the
refrigerating
system
so
as
to
filter out
the moisture from the system, then replace the filter, evacuate it again and
finally charge the system with refrigerant R134a.
b) Clogged with dirt in capillary
Analysis of Trouble
The capillary inlet is a place where coarse-grained dirt or refrigerant oil
in the system will tend to settle down and clog it. In case considerable dirt