8
Exploded view
Heat pump system components
1. Compressor
The compressor is to effect a low-temperature low-pressure evaporator refrigerant vapor sucked
and compressed into high temperature and pressure of the superheated vapor, and then discharged
to the condenser heat exchanger.
Inspiratory pipe
Exhaust pipe
Wiring box
5
6
7
9
10
13
12
11
1
2
3
4
14
15
8
Boiler signal wire
(HP250CM2 only)
(2*0.75mm2
,
White wire)
Power cable (3*1.5mm2)
Off-peak power
signal wire
(2*0.75mm2 ,Black wire)
Solar or boiler sensor
(HP250CM2 only)
(From hea
t pump)
1
Electric heater
2
Electric cover
3
Front cover - down
4
Display panel
5
Front cover - up
6
Control box
7
Compressor
8
Air grille
9
Air channel - up
Air channel - down
10
Fan
11
Four-way valve
12
Top cover
Tank case
13
14
15
Handle
S/N
Description
Содержание HP200M2