5
3. Technical parameters
Model
HP200M2
HP250M2
HP250CM2
Tank volume
200L
250L
245L
Rated voltage/ frequency
230V/50Hz
230V/50Hz
230V/50Hz
Tank rated pressure
0.85MPa
0.85MPa
0.85MPa
Corrosion protection
Magnesium rod
Magnesium rod
Magnesium rod
Water proof grade
IPX4
IPX4
IPX4
Type of extraction
Ambient / Exterior Ambient / Exterior Ambient / Exterior
COP@7
℃
/ EN16147
2.5
2.5
2.5
COP@15
℃
/ EN16147
2.9
2.9
2.9
Tapping cycle
L
L
L
Electric heater power
2150W
2150W
2150W
Average input - heat pump only
665W
665W
665W
Maximum input- heat pump only
850W
850W
850W
Maximum total power input of the
appliance
3000W
3000W
3000W
Standby power input/ Pes
33W
33W
33W
Max volume of usable hot water at 40
℃
setting at 55
℃
230L
300L
275L
Heating up time (7
℃
)
6.5h
8.5h
8.2h
Heating up time (15
℃
)
5.0h
6.8h
6.7h
Default temperature setting
55
℃
55
℃
55
℃
Temperature setting range- with heater
35
℃
-75
℃
35
℃
-75
℃
35
℃
-75
℃
Pressure drop in air circuit
25Pa
25Pa
25Pa
Max working pressure of refrigerant
0.8/2.8MPa
0.8/2.8MPa
0.8/2.8MPa
Refrigerant type / weight
R134a/0.9kg
R134a/0.9kg
R134a/0.9kg
Noise pressure level (2m)
40dB
40dB
40dB
Ambient temperature for use of product
-5~35
℃
-5~35
℃
-5~35
℃
Operating temperature of heat pump
-5~35
℃
-5~35
℃
-5~35
℃
Water inlet and outlet connection
G3/4"F
G3/4"F
G3/4"F
Safety valve connection
G3/4"F
G3/4"F
G3/4"F
Drain & Water intlet connection
G3/4"F
G3/4"F
G3/4"F
Product Dimensions
600*629*1692mm 600*629*1987 mm 600*629*1987 mm
Packing dimension without pallet
736*695*1810 mm 736*695*2120 mm 736*695*2120 mm
Packing dimension with pallet
736*695*1940 mm 736*695*2250 mm 736*695*2250 mm
Net/Gross weight
104/118kg
117/131kg
136/150kg
* The COP and noise level data was tested in Haier lab
Tank
Performances
Dimension and connections