Description of the pictograms
22
Symbol
Description
Hot water volume display.
Boost mode. Heat pump and Auxiliary electrical heater
are activated at the same
time(only in AUTO mode).
Heat pump working icon
.
Auxiliary electrical heater working icon
.
Time of peak/off-peak hours. In Time of peak/off-peak hours
mode, the symbol corresponding to the mode is displayed.
When receiving the signal, "HC" lights up.
Anti-
legionella
- Anti-legionella function will be activated every 7 days to
heat the tank to 65°C automatically .
Note:
Under certain conditions, ECO mode may result in shortages of hot water
(mainly due to air temperatures outside the operating range).
When the PV function is turned on, the setting temperature will
be automatically adjusted to 65
°C
,
when the PV effective signal
is received, the heat pump and electric heating will be turned on
at the same time.
When receiving the SG signal, the setting temperature will be
automatically adjusted to 65
°C
, and the heat pump will be
heated according to the logic of setting the temperature to
65
°C
.