![Haier HHS-1X5K Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/haier/hhs-1x5k/hhs-1x5k_user-manual_4863873030.webp)
27
Please refer to the table below to set inverter manufacturer parameters.
Inverter manufactures
APP setting
Default
INV-01
ESO
INV-02
Goodwe ET
INV-03
/
INV-04
/
INV-05
/
INV-06
Haier HV
INV-07
/
INV-08
/
INV-09
/
INV-10
6
Maintenance and troubleshooting
6.1
Routine maintenance
Maintenance charge every 6 months
From the date of manufacturer shipment, the battery shall be maintained every 6 months. Action
must be taken in case SOC reaches 0%.
Ambient temperature
Must be recharged within
(45, 50] °C
7 days
(35, 45] °C
15 days
≤35°C
30 days
Disconnect the battery if not being used
BMS consumes power even when the battery is not being used. Disconnect the battery output to
prevent the battery from becoming empty. For store-away, make sure the SOC is between 45%
and 55% before disconnect.
①
②
③
④