background image

Serial Number:                                                    Version:00.00

                           

Edition: 2006-1 

   
 

   

Dishwasher

                       

    Model: HDB18EB

 

 

Page 8 of 8 

Connect it well 

change thermo limiter 

change      heater 

 

Whether socket connector is connected well 

Program 

controller  or  circuit  is 

broken 

Whether heater is OK   

 

Whether  thermo  limiter  is 

OK 

       

Maintenances Services and Trouble Shooting 

 

analysis of the common breakdowns 

 

       

Heating trouble 

   

Phenomenon: water cannot be heated

 

Check: 

 

         

       

                  N 

 

 

                                 

 

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

N   

 

 

 

 

 

 

 

 

 

 

Содержание HDB18EB

Страница 1: ...old Dishwasher SERVICE MANUAL Models HDB18EB HDB18EBS Features Overflow Protection Function 5 Programs Pots and Pans Normal Light Glassware Rinse Hold Super Capacity for 8 settings 18 inches width DW 8888 27 ...

Страница 2: ...tion HDW A B C A Haier Dishwasher B The width of dishwasher C Series of factory design Examples HDB18EB It represents automatic spraying Haier Dishwasher the dishwasher s width is 18 inches 2 Features 2 1 Overflow Protection Function 2 2 5 Programs Pots and Pans Normal Light Glassware Rinse Hold 2 3 Super Capacity for 8 settings 2 4 18 inches width ...

Страница 3: ... allow children to play in or on the appliance Close supervision of children is necessary when the appliance is used near children 17 This appliance must be connected to proper electrical outlet with the correct electrical supply 18 Proper grounding must be ensured to reduce the risk of shock and fire DO NOT CUT OR REMOVE THE GROUNDING PLUG If you do not have a three prong electric receptacle outl...

Страница 4: ...ou could damage the door seal 30 When removing an old dishwasher from service or discarding it remove the front door 31 Disconnect electrical power and water inlet hose to dishwasher before servicing 3 Function Schedule 1 Pots and Pans wash 2 Normal Wash 2 Light Wash 3 Glassware wash 4 Rinse Hold Rinse with cold water Rinse with hot water Main wash at 55 Pre wash with cold water Drying Dying Hot r...

Страница 5: ...ting 4 1 Maintenances Services It may occur that the dishwasher does not function or does not function properly Before calling for assistance Iet us see what can be done first have you forgotten to press one of the buttons or to perform an essential operation 4 2 Trouble Shooting analysis of the common breakdowns Door switch trouble Phenomenon the dishwasher does not work N Y Open the door and che...

Страница 6: ...m controller is broken Maintenances Services and Trouble Shooting analysis of the common breakdowns water supply trouble Phenomenon water level cannot reach the required location N Y N Y Y Y N N Y measure whether solenoid valve is electrified Change the solenoid valve Whether water is flowing in the hose Whether the stopcock is turned on Turn on the stopcock Change water level switch user s water ...

Страница 7: ...ysis of the common breakdowns Drain pump trouble Drain pump trouble Drain pump trouble Drain pump trouble Phenomenon water cannot be drained N N Whether drain pump is working Whether drain pump is electrified circuit is damaged Y Y Drain pump is broken Drain hose is too high Y Whether pipeline is ok is ok Drain hose is too high ...

Страница 8: ...hermo limiter change heater Whether socket connector is connected well Program controller or circuit is broken Whether heater is OK Whether thermo limiter is OK Maintenances Services and Trouble Shooting analysis of the common breakdowns Heating trouble Phenomenon water cannot be heated Check N Y N Y Y N ...

Страница 9: ...keep on working Y N Y N N N Y Y N Y Whether the water overflow switch is ok Whether water is deposited is the bottom case Whether water flows out of the water overflow conduit Bottom case is leaking change water overflow switch check water supply solenoid valve change the solenoid valve Program controller is broken check the water level switch change the water level switch Program controller is br...

Страница 10: ...ure whether power Supply switch is OK Maintenances Services and Trouble Shooting analysis of the common breakdowns Power supply trouble Phenomenon water cannot be heated Check check whether the power connector N is in position Y N Y Connect it properly check whether the power connector is in position change the power supply switch ...

Страница 11: ...Serial Number Version 00 00 Edition 2006 1 Dishwasher Model HDB18EB Page 11 of 11 Circuit Diagram 5 Circuit Diagram CL 1 60 ...

Страница 12: ...Serial Number Version 00 00 Edition 2006 1 Dishwasher Model HDB18EB Page 12 of 12 Sincere Forever ...

Отзывы: