Indoor unit

1.Fitting of the Mounting Plate and Positioning of the wall Hole

When the mounting plate is first fixed

1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
   fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
    the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape

3

2.Making a Hole on the Wall and Fitting the Piping Hole Cover

Make a hole of 70 mm in diameter,

slightly descending to outside the wall.

Install piping hole cover and seal it

off with putty after installation

When the mounting plate is fixed side bar and lintel

Refer to the previous article, "    When the mounting plate is first fixed   ", for the
position of wall hole.

Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten

the plate to the fixed mounting bar.

3.Installation of the Indoor Unit

Drawing of pipe

[ Rear piping ]

Draw pipes and the drain hose, then fasten them with the adhesive tape

[ Left

Left-rear piping ]

In case of left side piping, cut away, with a nipper, the lid for left piping.

In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear

piping which is marked on heat insulation materials.

(Section of wall hole)

Piping hole pipe

Outdoor side

Thickness
of wall

Indoor side

Wall hole

70mm

G

Find the level position

B=   70mm

A=145mm

35

Содержание H2SM- - annexe 17

Страница 1: ...upporting plate No Accessory parts Remote controller R 03 dry battery Mounting plate Drain hose Screw Plastic cap Drain elbow Cushion 2 1 2 3 4 5 6 7 8 4 2 2 8 1 4 Number of articles Accessory parts 4...

Страница 2: ...left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or...

Страница 3: ...piping hole cover and seal it off with putty after installation When the mounting plate is fixed side bar and lintel Refer to the previous article When the mounting plate is first fixed for the posit...

Страница 4: ...or unit then take off wiring cover by removing its screws When connecting the cable after installing the indoor unit 1 Insert from outside the room cable into left side of the wall hole in which the p...

Страница 5: ...must be incorporated in the fixed wiring in accordance with the wiring rules The power plug is self provided the power plug must acquired the local attestation When connecting the cable before instal...

Страница 6: ...areful that matters such as wastes of sands etc shall not enter the pipe The standard pipe length is 5m If it is over 5m the function of the unit will be affected If the pipe has to be lengthened the...

Страница 7: ...kage No gas leakage In case of gas leakage tighten parts of pipe connection If leakage stops then proceed steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valve r...

Страница 8: ...ried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that draina...

Страница 9: ...tioning product is marked with this sym bol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dis mant...

Страница 10: ...los productos el ctricos y electr nicos no deben mezclarse con el resto de resi duos dom sticos no clasificados No intente desmontar el sistema usted mismo El des mantelamiento del acondicionador de...

Страница 11: ...oduct 2 the additional refrigerant amount charged in the field and 1 2 the total refrigerant charge on the refrigerant charge label supplied with the product The filled out label must be adhered in th...

Страница 12: ...refrigerante cargado en campo y 1 2 la carga total de refrigerante En la etiqueta de carga de refrigerante suministrada con el producto La etiqueta rellenada debe pegarse cerca de la conexi n de carga...

Отзывы: