– 45 –
Fault
Code
Load to Control
Timeout / Notes
F59
Dry Heater Thermistor Error - Out
of Range Low
Check that the thermistor harness is plugged in. Check
that the terminals are not bent inside the connector
housing.
F60
Heater Relay Stuck on Fault
Clear faults and cycle power to unit. If fault reoccurs
within 60 seconds of power up, replace MC board.
F61
CSM Check Failed
Cycle power and start cycle to clear fault. If fault does
not clear, replace main control.
F62
Dry Heater Fan Error
Check dry heater fan operation and verify speed is
greater than 2,500 RPM. Check that the dry heater fan
harness is plugged in.
F63
Flood Condition Fault
The pressure sensor has detected the water level
above the flood limit. Check the water valve for a stuck
open valve (continuous fill into the tub). Run the Fill
Test under the Diagnostics Test tab and ensure the
pressure sensor is in the range of 40.77 and 40.44 Hz.
Check that the fill funnel or door vent conduit at the
bottom of the door is not obstructed or blocked. This
can cause a pressure build up in the tub as the unit
heats during a cycle.
F64
Ignore Fault
Ignore fault.
F66
Dry Heater Thermal Cut Off (TCO)
Fault
Check harness. May need to replace the dry heater.
F86
No Fill Failure
Check the water valve; see if a water source is hooked
up to the dishwasher.
F87
Dry Heater Diagnostic Fault
Possibly any error with dry heater/relay/fan.
F96
Ignore Fault
Ignore fault.
F97
Absent Heat Source
Verify proper water level (no water will trip TCO).
Check heater TCO (replace TCO and harness if
tripped). Check heater. Check thermistor. Check main
control.
F98
Non-Draining Sump (Turbidity
Based)
Verify proper drain pump operation, restrictions and
installation.
F99
Minimum Wash Temp Not Met
Verify proper water level (no water will trip TCO).
Check heater TCO (replace TCO and harness if
tripped). Check heater. Check thermistor. Check main
control.
F112
Key Stuck
Pushbutton Models
: Check button operation, each
button should “click”. Check for plastic flash. Replace
user interface (UI) board.
Capacitive Touch Models:
Inactive F112's can indicate
inadvertent button contact, controls in Delay Start or
Control Lock mode, and consumer education. Check
that each key operates, each button should "beep"
and light up once pressed. If a key doesn't respond,
replace user interface (UI).
F128
Low Rinse Aid
Low rinse aid detected.