Earthing
Warning
Warning
Immediately cut off power supply
and contact our Service Centre
once the water heater does not
work properly or emits burnt smell.
230V/50Hz independent power
source must be used at all times.
Warning
Do not use damaged wire and
power socket. Promptly clean the
dust on the power plug and socket.
Do not touch the plug with wet
hands, and make sure that the water
heater, plug socket do not come into
contact with water. If they are
accidentally wet, they must be
checked by professional persons
appointed by our company before
using, in order to prevent electrocution.
Do not connect to power when
installing or repairing the water
heater.
Warning
Warning
Forbidden
Forbidden
Forbidden
Forbidden
Non-professionals are strictly
prohibited from carrying out repairs,
maintenance, dismantling or
revamping of the water heater.
Installation of water heater outdoors
is strictly prohibited.
Forbidden
Forbidden
Do not install the water heater in an
environment which is susceptible to
ice-formation. Ice will cause the
container and water pipe to break,
leading to scalding and water
leakage.
Please take precautionary
measures during cold weather, in
order to prevent damage to water
heater from freezing.
If the soft power cable is damaged,
it must be replaced by professional
staff from the manufacturers or
Haier Service Center in order
to avoid danger.
Caution
Take care not to be scalded by
heater water.
Touching of hot water valve and
pipes is strictly prohibited.
Make sure to check the water
temperature before use; use
only when it feels suitable.
Forbidden
Do not use water from the water
heater for drinking or similar purposes.
Caution
Please cut off the power supply if the
water heater was not used for an
extended period of time. Drain the
water heater of all water according to
the instructions in the chapter on
Cleaning and Maintenance.
Prohibited
Compulsory Matters
Essential Matters
Forbidden
Caution
Meanings of Icons
0040509739
Specifications
Troubleshooting
Technical Parameters
Introduction Of Exterior And Accessories
Symptom
Things to Check
Solutions
No water
1 Whether the water supply has
stopped or whether the water
pressure is too low
Check
2 Whether the water-usage
point is blocked
Check and clear
Only cold water
but the heating
indicator light
is glow
1 Whether mixing valve is
towards cold water side
Check and open hot water mixing valve.
2 Whether the water
temperature is adjusted
Increase the temperature to the required value.
Once the water is heated to the pre-set
temperature, control flow volume of cold and
hot water using the moderating mixing valve.
3 Heating time is too short
and set temperature is not
achieved
Continue heating
4 Whether heating pipe is
damaged
Confirm this is not due to the reasons 1, 2 , 3,
then contact Haier Service Person.
Only cold water
and the heating
indicator light
is not glow
1 Whether power is properly
connected
Check power socket
2 Whether thermostat is out
of control
Confirm this is not due to the reason 1,
then contact Haier Service Person.
Heating
indicator light
is on all the time
1 Water has not reached the
set temperature
Continue heating
2 Whether thermostat is out
of control
Confirm this is not due to the reason 1,
then contact Haier Service Person.
Water volume
is sometimes
large or small,
or water is
sometimes
hot or cold
Whether water pressure is
stable
Set lower mixing valve or ensure water
pressure is stable before use
Small hot water
outlet volume
1 Whether t he present
temperature set ting is too
low
Calibrate using the method stipulated in the
Instruction Manual
2 Whether water pressure is
excessive
Set lower mixing valve
Haier Home Water Heater
Instruction Manual
Safety Notices
(Please read before use)
=
Please read this Instruction Manual carefully before use.
=
Please retain this manual for future reference.
ES15V-SD(I/W)
Remarks:
The permitted error limit of above net weight is ±10%.
Item
Unit
ES15V
ES25V
V
230
230
Rated Frequency
Hz
50
50
Rated Pressure
MPa
0.80
0.80
Rated Power
W
2000
2000
kg
Rated Capacity
L
15
25
Waterproof Grade
IP
IPX4
IPX4
Mixing Factor (maximum)
%
Tap Water Pressure (minimum)
MPa
0.05
0.05
Mean Hot Water Output (minimum)
o
C
of 50
o
C) (maximum)
Minutes
Diameter of Power Wire
mm
2
3×1.5
3×1.5
35
65
45
13
35
65
25
10
Model
a
b
c
d
e
ES15V-SD
390mm
355mm
60mm
390mm
460mm
412mm
60mm
460mm
Note:
(Fig. 2)
Rev.00;29.08.20
ES25V-SD(I/W)
Electrical Diagram
a
d
e
c
b
Inner Tank
100mm
100mm
ES25V-SD
ES15V-EC-SD
ES25V-EC-SD
L: Live Wire(Brown/Red)
N: Neutral Wire(Blue/Black)
MT: High temperature limiter
RT: Sensor
EH: Heating element
E: Earthing Wire(Yellow&Green)
E
EH
RT
MT
E
N
L
Display Panel
Relay
N
1
2