background image

17

16

FA-Electromagnetic interference inhibitor
R1

Heating1

R2

Heating2

T1

Thermal cut-out T2

Thermostat

L

Lamp

PS

Drainage pump

M

Motor

NTC

Temperature sensor

H

Humidity sensor

K2

Level switch

K1

Door switch

PCB1

PCB2

Printed circuit board

PCB1

PCB2

P

S

M

FA

R1

R2

T1

T2

L

K1 NTC

H

K2

K3

Power switch

K3

N

K3

L

G

Rated load(kg)

Type

Item

Power supply

Maximum operating current(A)

Maximum power(W)

Drying program

EDC1070W/EDC1070M

(220-240)V/50Hz

12

11

2800

Water proof level

IPX4

Dimensions(H×D×W)mm

855

×

620

×

595

17

16

FA-Electromagnetic interference inhibitor
R1

Heating1

R2

Heating2

T1

Thermal cut-out T2

Thermostat

L

Lamp

PS

Drainage pump

M

Motor

NTC

Temperature senso

H

Humidity sensor

K2

Level switch

K1

Door switch

PCB1

PCB2

Printed circuit board

PCB1

PCB2

P

S

M

FA

R1

R2

T1

T2

L

K1 NTC

H

K2

K3

Power switch

K3

N

K3

L

G

T

Item

7

×

×

Wiring Circuit

Specifications

Содержание EDC1070M

Страница 1: ...iner handle Name of Parts Door Plinth SAVE THESE INSTRUCTIONS Programming guide 10 Important Safety Instructions 2 3 Name of Parts 1 This diagram may be slightly different from the layout of the machine you have just purchased due to techincal improvements Read all instructions before using dryer Dryers are provided with operating care and in stallation instructions Warning 1 Drainage outlet Earth...

Страница 2: ...ation the dryer must be installed and electrically grounded by a qualified service person in accordance with local codes 14 Always disconnect dryer from electrical supply before attempting any service Disconnect power cord by grasping the plug not the cord 15 The dryer must only be used for its intended purpose 16 Do not sit on top of the dryer 17 If the supply cord is damaged it must be replaced ...

Страница 3: ...r the ambient temperature must not be lower than 10 nor higher than 35 Reversible Door its opening direction may be changed The procedure is as follows 1 Unscrew the 4 hinge screws holding the door onto the machine and remove the door 2 Unscrew the door and prise out the catch cover on the opposite side of the door and transpose them 3 Unscrew the door hinges and prise out the hinge covers on the ...

Страница 4: ...ice agent The dryer must be grounded securely Attention Before use clean any deposits from inside the drum of the dryer with a wet towel Clean debris on the filter screen to increase the drying efficiency Warning Do not tumble dry woollen or wool mixture articles unless the article is labelled to be suitable due to a possibility of shrinkage Load to dry Check care labels inside the garments CARE L...

Страница 5: ... seconds once again and the child lock will release When the program ends or during a power failure the child lock will release H LED screen The screen displays the remaining time for a program the delay time and other related information Note The remaining time to start a program is the default time for the program During operation with variation of factors such as the moisture content The actual...

Страница 6: ... the laundry is not removed after the drying program is complete the dryer will start the anti crease protection cycle automatically In the anti crease protection cycle the dryer s drum will run at a set interval to keep your laundry loose 7 Turning off the dryer Press the power keystroke to switch off the power supply and turn off the dryer at the wall socket 1 Turning on power Insert the power p...

Страница 7: ...r is emptied and the dryer will stop It will not restart until the container is emptied 4 Cleaning the condenser The condenser must be cleaned monthly Switch off the power supply before cleaning Hold the protrusions on both sides of the lower decor panel and open it 13 Using a coin or other tool push the slides on the cover to the position as shown in the figure and then remove the cover Turn the ...

Страница 8: ...ping The remaining time will be adjusted and corrected continuously and automatically based on the following factors Type of laundry Loaded amount The moist degree of laundry Ambient temperature The automatic adjustment is a normal operation 15 E2 E3 E5 E6 Prompt and Alarm Information In case of an improper operation or problem with the machine when it operates the code corresponding to the proble...

Страница 9: ...ype Item Power supply Maximum operating current A Maximum power W Drying program EDC1070W EDC1070M 220 240 V 50Hz 12 11 2800 Water proof level IPX4 Dimensions H D W mm 855 620 595 17 16 FA Electromagnetic interference inhibitor R1 Heating1 R2 Heating2 T1 Thermal cut out T2 Thermostat L Lamp PS Drainage pump M Motor NTC Temperature senso H Humidity sensor K2 Level switch K1 Door switch PCB1 PCB2 Pr...

Страница 10: ...he appliance in accordance with the operating instructions and or general misuse and or abuse which would include unforeseen accidents wear and tear and or earthquake flood lightning or any other natural disaster beyond the control of Kelvinator 7 Any attempt by an unauthorised person to repair or tamper with the appliance shall render this guarantee null and void 8 This guarantee does not include...