Warning
To avoid electric shock or personal injury, be sure to disconnect the freezer from power supply
before carrying out any repair or maintenance.
Make sure that no drug or suspended particles around the freezer will be breathed in at the
time of maintenance; otherwise they may result in health hazard.

Cleaning of the freezer

Clean the freezer once a month. Regular cleaning makes the freezer always brand-new.

Wipe off a little dust on the shell, inner compartments and all accessories of the freezer

with a dry cloth. If the freezer is very dirty, remove the dirt with a clean cloth and neutral
detergent, then wipe off the residual detergent with a wet cloth, and finally wipe the freezer
with a dry cloth. (Undiluted detergent may damage plastic parts. Please refer to the detergent
instructions for the dilution method.)

Never pour water onto the shell or into the preservation compartment of freezer; otherwise

the insulation layer may be damaged, resulting in faults.

The compressor and other mechanical parts are fully enclosed and require no lubrication.
Remove the frost or ice on the inner wall once a month.

Removal of frost on the inner wall
Frost usually forms on internal shelve, which may cause clearance between the cabinet body
and door seal and thus result in poor refrigerating effect. You may use the ice scraper provided
along with the freezer for defrosting. The following procedure is the method of defrosting
through emptying the freezer.
Note: Do not use any tool with sharp edges or corners such as knife or screwdriver for
defrosting.
1.

Take out all articles stored in the freezer and put them in another freezer or in a container
with freezing liquid carbon dioxide.

2.

Turn off the power switch.

3.

Open outer doors and leave them open for a period of time for defrosting.

4.

Wipe off water at the bottom of cabinet body with a dry cloth.

5.

After cleaning the cabinet body, turn on the freezer again.

6.

Put back the articles in the sufficiently cooled freezer.

Or you may use the “Defrost” key to defrost: after unlocking the keyboard, press and hold the
“Defrost” key for 5s, the compressor will stop running. This key doesn’t have automatic return
function. Therefore it is necessary to press and hold it for 5s again after defrosting ends, and
the compressor will resume normal running.
Battery maintenance

When the low-temperature freezer keeps working continuously, please test the battery

charge level every 15 days (please refer to the section of alarm test function on Page 12 for the
test method). In case of low battery charge level, make sure that the battery switch is on and
the battery is charged. When the battery has been charged for consecutive 7 days, please retest
the battery charge level. In normal conditions, the battery charge should be full. If low battery
charge level remains, it is recommended to replace the rechargeable battery.

The battery with power-down alarm function is a consumable item with 3-year service life.

If the battery has been used for more than 3 years, it may not act at the time of alarm. It is
recommended to replace the battery earlier. Please contact a Haier after-sales service
technician for the battery replacement.

Fault

Fault

Fault

Fault clearance

clearance

clearance

clearance

If the freezer goes wrong, please check the following possible fault points before
asking for repair:
Failure to start

Is the connection of power supply normal? Is the main power switch on?
Is supply voltage too low?
Were many articles put in the freezer at a time?

Poor cooling

Is ambient temperature too high?

Are the doors closed tightly? (The frost between the cabinet body and the door

seal may reduce the sealing performance of doors)

Is the temperature setting correct?
Is the freezer away from direct sunlight?
Is the freezer close to a heat source?
Are the rubber hole cover and heat-insulating materials of test through-hole placed

correctly?

Were many uncooled items put in the freezer in past several hours? (In this case,

the problem is temporary. You may raise the set temperature and then gradually
reduce it after the freezer starts and stops normally in a short time.)
Noise

Is the freezer installed on solid ground?
Is the freezer’s shell contact with any object?
Has the freezer been leveled by adjusting its legs?
Is the freezer in low-temperature running state?

If the freezer’s internal temperature is relatively high due to many items in it,
sometime it make noises. The noise will lower with the reduction of temperature in
the preservation compartment.

Please check whether the noise is from the compressor (the compressor noise of

low-temperature equipment is louder than that of household appliances)

Knocking sound. It may be caused by rapid cooling and contraction of internal

components. In this case, please make the freezer’s temperature reduce gradually
without abrupt temperature reduction in a short time.

Equipment

Equipment

Equipment

Equipment scrapping

scrapping

scrapping

scrapping

Warning
If the freezer is left unused for a long time in an unsupervised area, please keep
children away from it and make sure that its doors cannot be fully closed. Equipment
scrapping should be done by qualified persons. Be sure to remove the doors to avoid
accidents such as suffocation.

Содержание DW-40L508

Страница 1: ...tration No No 2580116 in 2008 approved by Shandong Food and Drug Administration for manufacturing medical devices updated This series of freezers is in conformity with the registration standard YZB Lu 0174 2009 Medical Medical Medical Medical Low Temperature Low Temperature Low Temperature Low Temperature Freezer Freezer Freezer Freezer Operating Operating Operating Operating Instructions Instruct...

Страница 2: ...re those articles with strict temperature requirements such as living creatures and flowers etc We hereby promise to provide a complete set of 1 5 value added services for you when you require installation or maintenance service for any Haier product 1 it means installation service will be done well only once 5 it means 5 combined services a Safety test service we will perform safety test in elect...

Страница 3: ...ion and warning signs are as follows The contents marked with this caution sign involve safety of both the product and user and must be strictly followed The contents marked with this prohibition sign describe absolutely prohibitory behaviors and must be strictly followed otherwise the freezer may be damaged or the user may be injured This sign is marked on the covers of high voltage electric appl...

Страница 4: ...autions precautions If poisonous harmful or radioactive substances are stored in it please use the freezer in a safe area Improper use may be harmful to health or environment In case of leakage of inflammable gas such as coal gas please close the valve involved in gas leakage open windows for exhaust ventilation and do not plug in or unplug the freezer Be sure to disconnect the freezer from its po...

Страница 5: ...l temperature has been low enough before putting articles in the freezer and the articles are put in the freezer in batches to prevent temperature rise The displayed temperature of low temperature freezer means the temperature at the temperature sensing probe in the preservation compartment Sometimes it is different from actual temperature in the center of preservation compartment but it will be g...

Страница 6: ... using a voltage stabilizer of 3kw and above in those areas with unstable voltage to ensure normal input voltage within 220V 10 9 The freezer must be grounded reliably 10 If the power socket is equipped with ground wire please check it for reliable grounding before use If the power socket is not equipped with ground wire be sure to ask a qualified technician to install proper ground wire Use Use U...

Страница 7: ...d will unlock and the display panel will show internal temperature If any key is pressed in 10s the keyboard will automatically be locked 2 Temperature setting In initial power on state press the Set key the display screen will show L0 and 0 will flash press this key again the display screen will show the default temperature setting i e 30 and the second digit will flash If the freezer is not used...

Страница 8: ...ature sensor at fault E0 The indicator flashes Low battery charge level Insufficient battery charge or the battery switch is not on E5 The indicator flashes 3 times Note If several alarms sound simultaneously each fault code displays 3s Display Display Display Display and and and and alarm alarm alarm alarm Note Always turn on the battery switch before starting the freezer The freezer will enter n...

Страница 9: ...t function on Page 12 for the test method In case of low battery charge level make sure that the battery switch is on and the battery is charged When the battery has been charged for consecutive 7 days please retest the battery charge level In normal conditions the battery charge should be full If low battery charge level remains it is recommended to replace the rechargeable battery The battery wi...

Страница 10: ...o the battery s positive pole and the blue wire to the battery s negative pole Do not misconnect otherwise the charging circuit of computer board would be burned out easily and the battery cannot be charged Specifications Specifications Specifications Specifications Technical data Model Ambi ent tempe rature Classif ication of electric shock proof protect ion Tempe rature range Effe ctive volu me ...

Страница 11: ...ng running running running In order to operate and use the recorder correctly please operate as follows 1 You will see the recorder upon opening its door 2 Switch on the backup power supply i e 9V DC battery in the upper left corner of recorder 3 Change a piece of new recording paper see the figure below 4 Remove the plastic cap from the recording pen and close the recorder s door Note The recorde...

Страница 12: ...ust adjust adjust it it it it except except except except for for for for special special special special cases cases cases cases After sales After sales After sales After sales service service service service The freezer is guaranteed for free by our company for one 1 year calculated from the date of purchase the invoice shall prevail Main components including compressor condenser evaporator main...

Отзывы: