Haier DW-40L508 Скачать руководство пользователя страница 8

Display

Display

Display

Display and

and

and

and alarm

alarm

alarm

alarm

Upon connecting to the power supply, the freezer will be on and the display screen
will show the freezer’s internal temperature.
Prompts for the working state of display panel:

“Lock” indicator: if the indicator lights up, it means that all keys are locked to

avoid misoperation.

“Alarm” indicator: if the indicator lights up or flashes, it means that a fault occurs.

Functions of keys:

Cancel buzz: in the locked or unlocked state, press the “Cancel buzz” key at the

time of alarm, the alarm sound will be cancelled and the visual alarm will not be
cancelled.

Alarm test: it is used to test normal working state of the alarm system and low

battery charge level. In the unlocked state, press this key, all the indicators will light
up, the buzzer will give an alarm and all digital tubes display “8”. In the locked state,
press this key at the time of alarm, corresponding fault alarm code will display.
Please identify the fault causes according to the table below.

Alarm

State

Fault
code

Indication

Buzzer

High
temperature
alarm

When

the

internal

temperature

is

higher

than the set temperature
for

high

temperature

alarm

E9

The

indicator

flashes

When

the

freezer

is

turned on for the first
time, the buzzer alarm
function

is

activated

after 5 hours according
to the default settings; in
normal

operation,

the

buzz alarm is given after
15min

Low
temperature
alarm

When

the

internal

temperature

is

lower

than the set temperature
for

low

temperature

alarm

E10

The

indicator

flashes

Power-dow
n alarm

Power-down

of

the

freezer

/

The

alarm

indicator
flashes;

black

screen

and

actual

internal

temperature
show alternately

the buzz alarm is given
after 30s

Over-high
ambient
temperature

Ambient

temperature

above 38

E14

The

indicator

flashes

Abnormal
sensor

Internal main sensor at
fault

E6

The

indicator

flashes

Buzz alarm

Ambient

temperature

sensor at fault

E0

The

indicator

flashes

Low
battery
charge
level

Insufficient

battery

charge or the battery
switch is not on

E5

The

indicator

flashes 3 times

Note: If several alarms sound simultaneously, each fault code displays 3s.

Display

Display

Display

Display and

and

and

and alarm

alarm

alarm

alarm

Note:

Always turn on the battery switch before starting the freezer. The freezer will enter

normal working state and charge the battery upon connecting to an AC power supply
meeting its requirements. In case of AC power failure, the battery will energize the
display screen for normal display. When the voltage of battery reduces to less than a
specified value due to discharge, it will stop energizing the display screen and thus
the display screen will not display any longer. When the battery is able to supply
electricity normally, to completely cut off the freezer’s power supply, just pull out its
AC power cord and turn off its battery switch. Then the display screen will not
display any longer.

Time

Time

Time

Time setting

setting

setting

setting for

for

for

for automatic

automatic

automatic

automatic alarm

alarm

alarm

alarm recovery

recovery

recovery

recovery

At the time of alarm, press the “Cancel buzz” key on the display panel, buzz alarm
will be cancelled (remote alarm will not be cancelled).
If alarm conditions remain, the buzz alarm will automatically recover after a pause of
30min.

Remote

Remote

Remote

Remote alarm

alarm

alarm

alarm terminals

terminals

terminals

terminals

The remote alarm terminals are located in the compressor compartment at the back of
freezer. Alarm signals are sent by these terminals with carrying capacity of DC 30V, 2A.
Contact output:
In normal conditions, both ends of connecting wire of remote alarm terminals are
open circuit. In alarm conditions, both ends of connecting wire of remote alarm
terminals are closed circuit.
To use the remote alarm function, connect the circuit as shown in the figure below.
Note: The remote alarm function is limited to three alarm modes - high temperature
alarm, low temperature alarm and power-down alarm.

Содержание DW-40L508

Страница 1: ...tration No No 2580116 in 2008 approved by Shandong Food and Drug Administration for manufacturing medical devices updated This series of freezers is in conformity with the registration standard YZB Lu 0174 2009 Medical Medical Medical Medical Low Temperature Low Temperature Low Temperature Low Temperature Freezer Freezer Freezer Freezer Operating Operating Operating Operating Instructions Instruct...

Страница 2: ...re those articles with strict temperature requirements such as living creatures and flowers etc We hereby promise to provide a complete set of 1 5 value added services for you when you require installation or maintenance service for any Haier product 1 it means installation service will be done well only once 5 it means 5 combined services a Safety test service we will perform safety test in elect...

Страница 3: ...ion and warning signs are as follows The contents marked with this caution sign involve safety of both the product and user and must be strictly followed The contents marked with this prohibition sign describe absolutely prohibitory behaviors and must be strictly followed otherwise the freezer may be damaged or the user may be injured This sign is marked on the covers of high voltage electric appl...

Страница 4: ...autions precautions If poisonous harmful or radioactive substances are stored in it please use the freezer in a safe area Improper use may be harmful to health or environment In case of leakage of inflammable gas such as coal gas please close the valve involved in gas leakage open windows for exhaust ventilation and do not plug in or unplug the freezer Be sure to disconnect the freezer from its po...

Страница 5: ...l temperature has been low enough before putting articles in the freezer and the articles are put in the freezer in batches to prevent temperature rise The displayed temperature of low temperature freezer means the temperature at the temperature sensing probe in the preservation compartment Sometimes it is different from actual temperature in the center of preservation compartment but it will be g...

Страница 6: ... using a voltage stabilizer of 3kw and above in those areas with unstable voltage to ensure normal input voltage within 220V 10 9 The freezer must be grounded reliably 10 If the power socket is equipped with ground wire please check it for reliable grounding before use If the power socket is not equipped with ground wire be sure to ask a qualified technician to install proper ground wire Use Use U...

Страница 7: ...d will unlock and the display panel will show internal temperature If any key is pressed in 10s the keyboard will automatically be locked 2 Temperature setting In initial power on state press the Set key the display screen will show L0 and 0 will flash press this key again the display screen will show the default temperature setting i e 30 and the second digit will flash If the freezer is not used...

Страница 8: ...ature sensor at fault E0 The indicator flashes Low battery charge level Insufficient battery charge or the battery switch is not on E5 The indicator flashes 3 times Note If several alarms sound simultaneously each fault code displays 3s Display Display Display Display and and and and alarm alarm alarm alarm Note Always turn on the battery switch before starting the freezer The freezer will enter n...

Страница 9: ...t function on Page 12 for the test method In case of low battery charge level make sure that the battery switch is on and the battery is charged When the battery has been charged for consecutive 7 days please retest the battery charge level In normal conditions the battery charge should be full If low battery charge level remains it is recommended to replace the rechargeable battery The battery wi...

Страница 10: ...o the battery s positive pole and the blue wire to the battery s negative pole Do not misconnect otherwise the charging circuit of computer board would be burned out easily and the battery cannot be charged Specifications Specifications Specifications Specifications Technical data Model Ambi ent tempe rature Classif ication of electric shock proof protect ion Tempe rature range Effe ctive volu me ...

Страница 11: ...ng running running running In order to operate and use the recorder correctly please operate as follows 1 You will see the recorder upon opening its door 2 Switch on the backup power supply i e 9V DC battery in the upper left corner of recorder 3 Change a piece of new recording paper see the figure below 4 Remove the plastic cap from the recording pen and close the recorder s door Note The recorde...

Страница 12: ...ust adjust adjust it it it it except except except except for for for for special special special special cases cases cases cases After sales After sales After sales After sales service service service service The freezer is guaranteed for free by our company for one 1 year calculated from the date of purchase the invoice shall prevail Main components including compressor condenser evaporator main...