manualshive.com logo in svg
background image

4

11

To ensure that customers can use water heater properly and safely, we here 
seriously inform our customers that you must contact the appointed 
professional serving personnel for installing and service. For any improper 
installment, our company will not burden any responsibility. 

When the power supply is connected, the pump is  electrified;Pay attention 
that connecting lines of pump are inserted stably, and can not load emptily. 
Before any maintenance and repair of water heater, please make sure that 
you cut off  other  power Supply. Non-professional persons are not allowed to 
adjust and maintain water supply.
Before electrification please make sure that machines are full with water, 
otherwise it will cause a system malfunction. Please make sure that the 
sockets are subject to national standards and are connected to the ground 
reliably. It is prohibited to use water heater without a reliable grounding.
The water heater is equipped with safety valves. for secure use, please do 
not change installment position personally. The evacuating tube nozzle 
should be downwards vertically and are open to the air so as to prohibit 
jamming the exit. A draining pipe is linked to the evacuating tube  nozzle and 
leads to the sewer opening. (the draining pipe is otherwise sold) 
Hot water with a temperature higher than 50

 might result in scalding and 

customers should mix hot water and cold water and then have a shower or 
wash.
In cases when water heater is seriously soaked, it must be checked by 
technical personnel ratified by our company before it is reused.
The hot water in water heater is not suitable for drinking. As a result of long-
term use, scale might be produced in the water tank. Meanwhile, the aging of 
the water pipe can result in a change of water quality. Therefore, when you 
wash rice and vegetables with water in the container, please wash them once 
again with clean tap water.

When collector equipment is installed, it can not be inversely placed.
Outdoor pipeline must use metal pipes.
Heat-preserving of pipelines must use specially designed materials by our 
company.

ollector equipment should be installed facing south.

Evacuating opening of the system safety valve should be connected to the 
release opening of sewage.
All parts of the whole system are not allowed to be disconnected personally 
otherwise, results should be burdened personally.

C

Particular warning Attentions in installment

   heats ahead according to the preset 65

 before the first heating period 

arrives the second day. In cases when  the machine is turned on, press the 
when the machine is turned on, press the mode key continually to enter 
intellectual heating mode. The green point in the working indication icon is on. 
When the electrical heating starts, the red point in the icon glistens. And when 
the electrical heating is over, the green point is constantly on. Press the 
setting mode and you can set the heating temperature, whose scope is 30

-

75

. Note: in this mode, the solar energy heating is not concerned.

3.introduction of other functions

A.the system has a function of electricity-loss memory and that of automatic 

starting when electrified.

B.high temperature protection: in the process of the water pump running, when 

the water temperature of water-storing tank exceeds the high-temperature 
protection temperature (85

) set by the system, the water pump will 

automatically stop running .

C.low temperature protection: when the water exiting temperature is lower than 

the low temperature protection temperature (4

) set by the system, the water 

pump will automatically start running at full speed. And when the temperature 
rises to 7

, the water pump will stop running.

D.malfunction protection: this system has circuit malfunction alarm (E1),high 

temperature alarm (E2), sensor malfunction alarm of collector equipment(E3), 
sensor malfunction alarm of water-storing tank (E4), as well as pipeline 
leakage and water pump empty running alarm (E5), etc. When these problems 
happen, the system will display malfunction code E1~E5. The above 
malfunction protection is non-restorable and therefore, the system can only 
normally run after malfunction is eliminated and the electricity is reconnected

4.interface indication and instruction for operation

After the solar water heater center is installed, to confirm that the water-
storing tank is full with water and to check that each pipeline is connected 
properly and not leaking. To check that the power supply of the water-storing 
tank corresponds to the requirements and then to connect power supply.

5.

Instruction for controller

A.turning on/ turning off: the system is turned on directly and automatically 

enters the working mode and conditions before power supply is cut off. The 
first tacitly approved working mode of the system is the solar heating mode. 
The four-number tube of the indication screen displays the clock. The five-
number tube under the screen respectively displays water temperature of 
water-storing tank and the temperature of water exiting. The indication 
interface is displayed in Fig. 6 and at this time, all the pressing keys are 
effective. Then press power supply key and the system will be turned off and 
enter the electricity saving mode. The indication interface is displayed in

Use method

Содержание BRF1- 120

Страница 1: ... Rev 01 specific number 0040500208 Group Qingdao Economic and Technical Development Zone Haier Water Heater Co Ltd website www haier com Solar Water Heater Sincerity For Ever Please read this manual carefully before use Please keep this manual for future reference Users Manual ...

Страница 2: ...ment of products Haier water heater you purchase might not consist with the figures in the instruction for which we apologize here to you Haier Correct Disposal of this product This marking indicates that this product shoud not be disposed with other househoud wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to ptomote the s...

Страница 3: ...exiting is cold No temperature rising Is water supply failed or water pressure too low Is water exit blocked Is hot water valve opened Indication E3 Large amount of water flows out of safety valve Indication E4 Indication E5 Is water temperature adjusted Is temperature controller loss of control Sunshine unsufficient Is Heating element idamaged Is the tap water pressure stable Unable to turn on Wh...

Страница 4: ... solar energy heating mode 4 In normal use the tap water entrance valve of water storing tank should be kept constantly open You only need to open the mixed valve to adjust water temperature when taking a bath and then you can use freely 5 Please pay attention to the temperature of water storing tank when taking a bath and avoid being scalded by too hot water or being hurt by too cold water 6 Plea...

Страница 5: ...dition Preset heating mode Indicating clock condition to set hour of the first preset heating time in fixing time to set minute of the first preset heating time in fixing time to set temperature of preset heating in fixing temperature to set hour of the second preset heating time in fixing time to set minute of the second preset heating time in fixing time to set temperature of the second preset h...

Страница 6: ...is turned off the solar heating and malfunction alarm protection are all working and only if the conditions for the running of the water pump are Satisfied water pump will run at full speed When malfunction alarm appears it will display malfunction code B Selection of working mode the system provides four working modes and customers can select any mode as the present working mode When the system i...

Страница 7: ...ng period arrives the second day In cases when the machine is turned on press the when the machine is turned on press the mode key continually to enter intellectual heating mode The green point in the working indication icon is on When the electrical heating starts the red point in the icon glistens And when the electrical heating is over the green point is constantly on Press the setting mode and...

Страница 8: ... starting conditions for water pump are reached then the water exiting temperature of collector equipment 20 Meanwhile when temperature difference between water exiting of collector and water in Water storing Tank is higher than the set value 6 or 10 water pump will start and run at full speed When the temperature difference is less than 2 water pump will automatically stop B simultaneous heating ...

Страница 9: ...ef vent due to normal expansion The vent shall always keep open to the air Avoid being blocked Ò Ø Æ Ê Ó Ã ò é 1 Function introduction of controlling board There are five icons on the indication screen among which are the following four icons solar energy simultaneous heating preset and intellectual power They respectively represent the four modes of the system working that is solar energy heating...

Страница 10: ...ank collector equipment and system pipeline Through cold water opening of tap water To close water exiting valve of hot water until the air is exhausted and water flows out continually Meanwhile to observe whether the system leaks and to keep the cold water entrance open in the process of use 8 Introduction of indication board 13 icon for intellectual power heating 14 upwards adjusting key 15 down...

Отзывы: