Service diagnosis
2
9
Domestic air conditioner
10.3.1 Thermistor or Related Abnormality
Indoor Display
★
ŶŶ(
Room temperature sensor failure
★
(
Heat-exchange sensor failure
Outdoor display
/('
flash 10 times
˖
Defrost temperature sensor failure
/('
flash 11 times
˖
Suction temperature sensor failure
/('
flash 12 times
˖
Ambient temperature sensor failure
/('
flash 13 times
˖
Discharge temperature sensor failure
Method of
The temperatures detected by the thermistors are used to determine thermistor errors
Malfunction
Detection
Malfunction When the thermistor input is more than 4.92V or less than 0.08V during compressor
.
n
o
i
t
a
r
e
p
o
n
o
i
s
i
c
e
D
Conditions
1RWH
The values vary slightly in some models
Supposed
Ŷ
Faulty connector connection
Causes
Ŷ
Faulty thermistor
Ŷ
Faulty PCB
Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
Thermistor resistance check method
Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using tester.The
relationship between normal temperature and resistance is shown in the value of indoor thermistor.
Thermistor resistance check
Is it normal?
Yes
NO
Yes
Is it normal?
NO
Check the connector connection.
Replace the thermistor
Replace the indoor unit PCB
Correct the connection
Содержание AS12TB3HRA
Страница 12: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 ...
Страница 14: ...Printed circuit board connector wiring diagram 12 Domestic air conditioner PCB 1 ...
Страница 53: ...three 6 Removal Procedure 4 Domestic Air Conditioner Remove the casing 1 2 3 ...
Страница 57: ...Removal Procedure 8 Domestic Air Conditioner motor cover motor cover ...
Страница 58: ...Removal Procedure 9 Domestic Air Conditioner ...