WARNING
(1) Remove the cord clamp.
(2) Process the end of the connection cords
to the dimensions shown in Fig.25.
(3) Connect the end of the connection cord
fully into theterminal block.
(4) Wiring
(Fig. 25)
(4) Fasten the connection cord with a cord clamp.
(5) Fasten the end of the connection cord with the screw.
(6) For series 24,28,36,42, the power cable and connecting cable are
self-provided.
ELECTRICAL WIRING
(1) Always use a special branch circuit and install a special receptacle to supply power to the room air
conditioner.
(2) Use a circuit breaker and receptacle matched to the capacity of the room air conditioner.
(3) The circuit breaker is installed in the permanent wiring. Always use a circuit that can trip all the
poles of the wiring and has an isolation distance of at least 3mm between the contacts of each pole.
(4) Perform wiring work in accordance with standards so that the room air conditioner can be
operated safely and positively.
(5) Install a leakage circuit breaker in accordance with the related laws and regulations and electric
company standards.
22
Installation of Indoor Unit
Y/G
1 2 3 N L
W B R BL BR Y/G
Y/G
OUTDOOR UNIT
TERMINIAL BLOCK
INDOOR UNIT
TERMINIAL BLOCK
1 2 3 N L
W B R BL BR Y/G
1HP,220-230V~,50Hz
POWER SUPPLY:
Y/G
1 2 3
W B R Y/G
Y/G
AC142ACBEA, AC182ACBEA
AC242ACBEA
AC28NACBEA, AC36NACBEA, AC42NACBEA
1HP,220-230V~,50Hz
POWER SUPPLY:
INDOOR UNIT
TERMINIAL BLOCK
L N
W B Y/G
Y/G
1 2 3
W B R Y/G
OUTDOOR UNIT
TERMINIAL BLOCK
INDOOR UNIT
TERMINIAL BLOCK
POWER SUPPLY:
3N~, 380-400V, 50Hz
R S T
N 1 2 3
1 2 3
W B R Y/G
Y/G
Y/G