background image

Installation Procedures

20

HOW TO CONNECT WIRING TO THE TERMINALS

A.  For solid core wiring (or F-cable)(Fig.24A)

(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the
     exposed solid wire.
(2) Using a screwdriver, remove the terminal screw(s) on the terminal board.
(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal
     screw using a screw driver.

B.  For strand wiring(Fig.24B)

(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the
     exposed strand wiring.
(2) Using a screwdriver, remove the terminal screw(s)on the terminal board.
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver.

Fig. 24

Insulation

Strip 25mm

Loop

A. Solid wire

Terminal
board

Screw with
special washer

Round
terminal

Wire

Screw with
special washer

Round
terminal

Wire

Strip 10mm

Round
terminal

B. Strand wire

After passing the connection cord and power cable through the insulation tube, fasten it with the cord
clamp, as shown in Fig.25

HOW TO FIXED CONNECTION CORD AND POWER CABLE AT
THE CORD CLAMP

Fig. 25

Insulation tube

Cord clamp

Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.

Содержание AC092ACBHA

Страница 1: ...92ACBHA AU092AABHA HCFU 09HA03 R1 B AC122ACBHA AU122AABHA HCFU 12HA03 R1 B No 0010572437 A CONVERTIBLE TYPE AIR CONDITIONER Please read this operation manual before using the air conditioner Please keep this manual carefully and safely ...

Страница 2: ...ents Cautions Safety Precautions Features and Functions Name of Parts Installation Cleaning and Care Trouble Shooting Operation Tips Installation Tools Installation Procedures 1 2 3 4 5 6 7 8 9 10 11 12 23 ...

Страница 3: ...ckaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon All these valuable ma...

Страница 4: ...ircuit imprimÈ ª Lorsque le climatiseur est installÈ en plafonnier placer líinterrupteur K1 ª de la carte circuit imprimÈ sur la position D ª Lorsque le climatiseur est installÈ au sol placer cet interrupteur sur la position L ª ó sur les appareils tout neufs il se trouve par dÈfaut en position D ª For this model the all pole discon rexion connection method should be applied in the power supply Su...

Страница 5: ...ell etc stop operation immediately turn off the circuit breaker and consult authorized service personnel Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatuses Do not climb on place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of the air conditioner Do not expose the air con...

Страница 6: ...turns off HEAT COOL TYPE When the SLEEP button is pressed during Heating mode the air conditioner s thermostat setting gradually lowers during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation MILDEW RESISTANT FILTER The AIR FILTER has been treate...

Страница 7: ...Receiver 4 Power Indicator Lamp Red 5 OPERATION Indicator Lamp Green 6 TIMER Indicator Lamp Yellow 7 Compressor Run Lamp Green 8 Intake Grill Fig 3 9 Air Filter 10 UP DOWN Air Direction Flaps 11 RIGHT LEFT Air Direction Louvers behind UP DOWN Air Direction Flaps 3 9 8 Fig 1 11 10 1 2 3 4 5 1 3 4 2 5 Air inlet Air outlet Drain hose Connecting piping and electrical wiring ...

Страница 8: ...nt in the air c Near to hot spring with high content of sulfide gases d Area with frequent fluctuation of voltage e g factory etc e In vehicles or ships f Kitchen with heavy oil vapour or humidity g Near to the machine emitting electric magnetic waves h Places with acid alkali vapuor TV radio acoustic appliances etc are at least 1 m far away to the indoor unit outdoor unit power Earthing wire shou...

Страница 9: ...m After washing allow the Air Filters to dry thoroughly in an area protected from sunlight 1 2 3 The Filters fit onto the inside of the intake Grill figure 1 The bottom edges of the Air Filters should fit into the filter brackets figure 1 The Air Filters should be pushed down so that their top edges fit under the projections at the top of the Intake Grill figure 2 Dust can be cleaned from the Air ...

Страница 10: ...xpanding or shrinking because of temperature changes This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the furniture When unit is running at places like restaurant etc where dense edible oil fumes always exist this will happen To prevent frost from accumulating on indoor heat exchanger unit will switch to blowing operation for a w...

Страница 11: ...tacles in inlet or outlet grill Are horizontal louvers at up position in heating mode Any doors or windows left open Is there any direct sunlight in the room If there are unexpected heat sources in the room Too many people in the room Poor cooling Is air conditioner in standby condition in heating mode Cold air blows out in heating mode If your unit still can t work properly after above mentioned ...

Страница 12: ...itioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you fe...

Страница 13: ... Coupler heat insulator small 1 For indoor side pipe joint Small pipe Nylon fastener 1 For fixing the drain hose Drain hose Non adhesive tape 1 1 VT wire 1 For fixing the drain hose L 280mm Remote controller Battery 1 2 Use for air conditioner operation For remote controller unit Name and shape Q ty Application 1 Cover plate left Cover plate right Installation template Anchor bolt Spring washer Sp...

Страница 14: ...will not topple or fall WARNING CAUTION Decide the mounting position with the customer as follows 1 INDOOR UNIT 1 Install the indoor unit level on a strong wall floor ceiling which is not subject to vibration 2 The inlet and outlet ports should not be obstructed the air should be able to blow all over the room 3 Install the unit near an electric outlet or special branch circuit 4 Do not install th...

Страница 15: ...he outdoor unit in a place where the drain water flow will not be obstructed Reverse cycle model only 5 Do not place animals and plants in the path of the warm air 6 Take the weight of the air conditioner into account and select a place where noise and vibration are small 7 Select a place where the warm air and noise from the air conditioner do not disturb neighbors 8 Provide the space shown in Fi...

Страница 16: ...ng set to wall install the accessory wall bracket at the position shown in Fig 5 and mount the set to it Fig 1 Machine screw Tapping screw Tapping screw Intake grill Fig 5 Wall bracket Side of set 65 5cm 99cm 50cm 24 5cm 6 5cm 12 5cm 10cm 6 5cm 53cm 4 5cm 7cm hole 3 5cm hole The drain hose can be connected to either the left or right side Fig 3 Fig 3 Drain hose Left side Drain hose Right side Wall...

Страница 17: ...h Height A should be less than 5 mm Fig 9 Fig 8 Be sure to arrange the drain hose correctly so that it is leveled lower than the drain hose connecting port of the indoor unit Drain pan Drain hose Nylon fastener Drain pan Drain hose Insulation Drain hose OK NO NO Arrange the drain hose lower than this portion Drain hose Fig 9 A A Drain hose B UNDER CEILING TYPE Using the installation template drill...

Страница 18: ... AND INSTALLING THE ANCHOR BOLTS When the directions are selected drill 80mm and 50mm or 150mm dia hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow With a concrete drill drill four 12 7 mm dia Holes Fig 13 Wall 6mm Install the drain hose at the rear it should not be installed on the top or right side Fig 11 Rear Install the drain hose in the direction R...

Страница 19: ...PING OUTDOOR UNIT INSTALLATION 1 FLARE PROCESSING 1 Cut the connection pipe with pipe cutters so that the pipe is not deformed 2 Holding the pipe downward so that cuttings cannot enter the pipe remove the burrs 3 Remove the flare nut from the indoor unit pipe and outdoor unit and assemble as shown in Table1 and insert the flare nut onto the pipe and flare with a flaring tool 4 Check if the flared ...

Страница 20: ...is installed by referring to the following Fig 22 18 3 Limitations for one way piping length and vertical height difference 2 Piping size Install the removed flare nuts to the pipes to be connected then flare the pipes 90 0 5 3 Refrigerant piping 1 Outline of piping Gas pipe 12 70 1 2 x1 2mm 6 35 1 4 x0 8mm Liquid pipe Outdoor unit 3 way valve Flare connection Gas pipe Liquid pipe Flare connection...

Страница 21: ...the valve rod s cap for 2 way valve and 3 way s connect the service port into the projection of charge hose low for gaugemanifold Then connect the projection of charge hose center for gaugemanifold into vacuum pump To use vacuum pump CAUTION If the refrigerant of the air conditioner leaks it is necessary to make all the refrigerant out then charge the liquid refrigerant into air conditioner accord...

Страница 22: ... the insulation to about 10mm of the exposed strand wiring 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using a round terminal fastener or pliers securely clamp a round terminal to each stripped wire end 4 Position the round terminal wire and replace and tighten the terminal screw using a screw driver Fig 24 Insulation Strip 25mm Loop A Solid wire Terminal board Screw ...

Страница 23: ...t the ground wire Electric component box Fig 27 Electric component box Remove the four tapping screws CAUTION Do not remove the screws If the screws are removed the electric component box will fall 2 Pull out the electric component box Fig 28 3 Remove the electric component box cover Fig 29 Base Electric component box cover Remove the three tapping screws 1 Remove the cord clamp 2 Process the end ...

Страница 24: ...se a special branch circuit and install a special receptacle to supply power to the room air conditioner 2 Use a circuit breaker and receptacle matched to the capacity of the room air conditioner 3 The circuit breaker is installed in the permanent wiring Always use a circuit that can trip all the poles of the wiring and has an isolation distance of at least 3mm between the contacts of each pole 4 ...

Страница 25: ......

Отзывы: