Haier AB09SC2VH2 Скачать руководство пользователя страница 8

Page 8

WIRED CONTROLLER

ENGLISH

Press the SET key. The swing louver function icon 

will be displayed. Press the 

pq

 keys to advance 

through the functions to select the SLEEP func

-

tion. The Sleep and Sleep “off” time icons will be
displayed. (The Sleep icon will be flashing) Press the TIME key, 
the “off” icon will begin to flash. Press the 

pq

 keys to set the 

“off” time. (Time range is 0.5h to 72h) Press the SET key to 
confirm the setting. The Sleep function and “off” time icons 

will remain on.

If neither 

pq

 key is pressed within 10 seconds, or if the 

MODE, FAN, or ON/OFF keys are pressed prior to pressing the 
SET key, the setting function is canceled and reverts back to 

the previous setting.

To cancel the Sleep function. Press the SET key. The swing 

louver function icon will be displayed. Press the 

pq

 keys to 

advance through the functions to select the SLEEP function. 
The Sleep and Sleep “off” time icons will be displayed. (The 
Sleep icon will be flashing) Press the SET key to cancel the 

function.

noTe:  This function requires the  on/off key leD to be 
turned on and the screen backlight to be illuminated. 

sleep function

 The Filter Cleaning icon will start flashing when 

the indoor unit has reached 500 hours of operat-
ing time.

After cleaning or replacing the filter, press the SET key to clear 

the icon and reset the operating time.

noTe:  This function requires the  on/off key leD to be 
turned on and the screen backlight to be illuminated. 

filter Cleaning

oPeraTIon

settings & functions

Press the SET key. The swing louver function icon 

will be displayed. Press the 

pq

 keys to advance 

through the functions to select the Heat Reclaim 
Ventilation function. (The icon will be flashing) 
Press the SET key to confirm the setting.

To cancel the Heat Reclaim Ventilation function, repeat the 

above steps.

If neither 

pq

 key is pressed within 10 seconds, or if the 

MODE, FAN, or ON/OFF keys are pressed prior to pressing the 
SET key, the setting function is canceled and reverts back to 

the previous setting.

This function is reserved for future models.

noTe:  This function requires the  on/off key leD to be 
turned on and the screen backlight to be illuminated.

 

Heat reclaim Ventilation

note: These functions require the on/off key leD to be 
turned off and the screen backlight to be illuminated.

auto restart

Setting DIP switch SW1-4 located on the PCB of the wired 

control to the “on” position will disable the auto restart func

-

tion. When the switch is in the “off” position, auto-restart 
is enabled (default position). When the switch is in the “on” 
position, auto-restart is disabled.
Information retained in auto-restart are: Mode, Fan Speed, 
Temperature Setting, Swing State, and Heat Reclaim Ventila

-

tion function.      

Communication error of Wired Controller  

If there is no communication between the wired controller and 

indoor unit for 4 minutes, when checking error codes, “07” will 

be displayed in the upper right corner of the display. 

other functions

Содержание AB09SC2VH2

Страница 1: ...tures and Interface 2 Installation 3 4 Wired Controller Wiring Instructions 3 4 Dip Switch 4 Operation 5 8 Settings Functions 5 8 This system should be installed by a qualified HVAC professional Incorrect installation may cause fire water damage personal injury or death When abnormalities such as a burnt smell are detected immediately power off the main switch and contact a licensed contractor Do ...

Страница 2: ...ample if the temp is 25 C 77 F it will display 25 C 77 F Humidity display function is reserved Energy Saving function This icon will be dis played only when energy saving function is set Filter Cleaning Child Lock Lock Central Motion Sensing Reserved Left Right Swing This icon is displayed only when in swing function Up Down Swing This icon is displayed only when in swing function Sleep function T...

Страница 3: ...G 0 75mm2 x3 core shielded wire 300 400 ft 90 120m 16AWG 1 25mm2 x3 core shielded wire 400 500 ft 120 150m 14AWG 2mm2 x3 core shielded wire A One wired controller controls one indoor unit the indoor unit connects with the wired controller through a 3 conductor shielded cable C Two wired controllers control one indoor unit The wired controller that connects with the indoor unit is called the master...

Страница 4: ...nt temp display available OFF OFF Ambient temp display unavailable SW1 3 ON Display ambient temp from PCB of indoor OFF OFF Display ambient Temp from wired controller SW1 4 ON Auto restart invalid OFF OFF Auto restart valid SW1 5 ON Fahrenheit OFF OFF Celsius SW1 6 ON Swing angle adjustment available OFF OFF Swing angle adjustment unavailable SW1 7 ON Up Down and Left Right swing OFF OFF Up Down s...

Страница 5: ...the clock will default to 12 00 Within 10 seconds of the clock be ing displayed the time can be set The clock icon and minutes portion of the time display will be flashing Press the pq keys to adjust the minutes Pressing and holding the pq keys will accelerate the time adjustment With the minutes set press the TIME key The clock icon and hours portion of the time display will now begin flashing Pr...

Страница 6: ...eted Timer Function Setting OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select ECO function The icon will be flashing Press the SET key to confirm the setting The ECO icon will remain on To cancel ECO function repeat the above steps NOTE The energy saving default parameters are listed below 74...

Страница 7: ...s The child lock icon will disappear from the screen All normal functions of the keys will be restored Note This function requires the ON OFF key LED to be turned OFF and the screen backlight to be illuminated Press and hold the FAN keys for 5 seconds the current temperature compensation value is displayed in the upper right corner of the screen The default value is 00 Press the pq keys to change ...

Страница 8: ...N OFF key LED to be turned ON and the screen backlight to be illuminated Filter Cleaning OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select the Heat Reclaim Ventilation function The icon will be flashing Press the SET key to confirm the setting To cancel the Heat Reclaim Ventilation function r...

Страница 9: ...www Haier com Haier America Wayne NJ 07470 2015 Haier America Trading LLC Model YR E17 Issued Date May 2015 ...

Отзывы: