Haier AB09SC2VH2 Скачать руководство пользователя страница 3

WIRED CONTROLLER

Page 3

ENGLISH

InsTallaTIon

1. Put communication wire through the hole in the back cover 
as shown.

2. Mount the back cover in the desired location, making sure 

not to pinch the communication wire. Then connect the com-

munication wire to CON1 port of the wired controller. Replace 

the cover onto the unit to complete the installation.

Wired Controller Wiring Instructions

Communication Wiring

step by step Guide To slim Duct Unit Installation 

There are three methods to connect the wired controller to 
the indoor units.

Communication Wiring 
length

Dimension of Wiring

0~100 ft (0~30m)

22AWG(0.3mm

2

)x3-core 

shielded wire

100~200 ft (30~60m)

20AWG(0.5mm

2

)x3-core 

shielded wire

200~300 ft (0~90m)

18AWG(0.75mm

2

)x3-core 

shielded wire

300-400 ft (90~120m)

16AWG(1.25mm

2

)x3-core 

shielded wire

400~500 ft (120~150m)

14AWG(2mm

2

)x3-core 

shielded wire

A. One wired controller controls one indoor unit; the indoor 

unit connects with the wired controller through a 3 conductor 
shielded cable.

C. Two wired controllers control one indoor unit. The wired 
controller that connects with the indoor unit is called the 

master controller, the other is called the slave controller. The 

master wired controller and the indoor unit (as well as the 
master controller and the slave controller) are all connected 
through 3 conductor shielded cables. 

A

B. One wired controller can control up to 16 sets of indoor 
units (max); A 3 conductor shielded cable must connect 

the wired controller and the master unit (the indoor unit 
connected to the wire controller directly). The others connect 
to the master unit through a 2 conductor shielded cable.

B

Содержание AB09SC2VH2

Страница 1: ...tures and Interface 2 Installation 3 4 Wired Controller Wiring Instructions 3 4 Dip Switch 4 Operation 5 8 Settings Functions 5 8 This system should be installed by a qualified HVAC professional Incorrect installation may cause fire water damage personal injury or death When abnormalities such as a burnt smell are detected immediately power off the main switch and contact a licensed contractor Do ...

Страница 2: ...ample if the temp is 25 C 77 F it will display 25 C 77 F Humidity display function is reserved Energy Saving function This icon will be dis played only when energy saving function is set Filter Cleaning Child Lock Lock Central Motion Sensing Reserved Left Right Swing This icon is displayed only when in swing function Up Down Swing This icon is displayed only when in swing function Sleep function T...

Страница 3: ...G 0 75mm2 x3 core shielded wire 300 400 ft 90 120m 16AWG 1 25mm2 x3 core shielded wire 400 500 ft 120 150m 14AWG 2mm2 x3 core shielded wire A One wired controller controls one indoor unit the indoor unit connects with the wired controller through a 3 conductor shielded cable C Two wired controllers control one indoor unit The wired controller that connects with the indoor unit is called the master...

Страница 4: ...nt temp display available OFF OFF Ambient temp display unavailable SW1 3 ON Display ambient temp from PCB of indoor OFF OFF Display ambient Temp from wired controller SW1 4 ON Auto restart invalid OFF OFF Auto restart valid SW1 5 ON Fahrenheit OFF OFF Celsius SW1 6 ON Swing angle adjustment available OFF OFF Swing angle adjustment unavailable SW1 7 ON Up Down and Left Right swing OFF OFF Up Down s...

Страница 5: ...the clock will default to 12 00 Within 10 seconds of the clock be ing displayed the time can be set The clock icon and minutes portion of the time display will be flashing Press the pq keys to adjust the minutes Pressing and holding the pq keys will accelerate the time adjustment With the minutes set press the TIME key The clock icon and hours portion of the time display will now begin flashing Pr...

Страница 6: ...eted Timer Function Setting OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select ECO function The icon will be flashing Press the SET key to confirm the setting The ECO icon will remain on To cancel ECO function repeat the above steps NOTE The energy saving default parameters are listed below 74...

Страница 7: ...s The child lock icon will disappear from the screen All normal functions of the keys will be restored Note This function requires the ON OFF key LED to be turned OFF and the screen backlight to be illuminated Press and hold the FAN keys for 5 seconds the current temperature compensation value is displayed in the upper right corner of the screen The default value is 00 Press the pq keys to change ...

Страница 8: ...N OFF key LED to be turned ON and the screen backlight to be illuminated Filter Cleaning OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select the Heat Reclaim Ventilation function The icon will be flashing Press the SET key to confirm the setting To cancel the Heat Reclaim Ventilation function r...