14K 18K
1.
To bend a pipe, give the roundness as large as possible not to crush the pipe ,
ƽ
and the bending radius should be 30 to 40 mm or longer.
Connecting the pipe of gas side
fi
rst makes working easier.
ƽ
The connection pipe is specialized for R410A.
ƽ
Half union
Flare nut
Torque wrench
CAUTION:
Be careful that matters, such as wastes of sands,water,, etc. shall not enter the pipe.
Spanner
Forced fastening without careful centering may
damage the threads and cause a leakage of gas.
Pipe Diameter(
ǿ
)
Fastening torque
Liquid side6.35mm(1/4")
18N.m
Liquid/Gas side9.52mm(3/8")
42 N.m
Gas side 12.7mm(1/2")
55N.m
Gas side 15.88mm(5/8")
60 N.m
Connection of pipes
2.
In case the elevation B is more than 5m,
oil trap shoud be installed every 5~7m
Max. Length: B1 max =20m B2 max =20m
Max.Elevation: A1 max =15m A2 max =15m
In case the pipe total length (B1+B2) is more than
20m, the refrigerant should be charged, according
to 20 g/m.
B
Outdoor unit
Indoor unit
A1
B1
Indoor unit
A2
B2
Outdoor unit
Indoor unit
B1
Indoor unit
B2
Outdoor unit
Indoor unit
Oil trap
A3
A3 max =15m
(B1+B2) max =30m
Outdoor unit
Indoor unit
A1
B1
Indoor unit
A2
B2
CAUTION
Indoor unit
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. The standard pipe
length of each indoor unit is 5m. If total pipe length is over 20m, the function of the unit will be
affected, charge more refrigerant is needed, according to 20 g/m. But the charge of refrigerant
must be conducted by professional air conditioner engineer. Before adding additional refrigerant,
perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge
additional refrigerant.
Installations
Domestic air conditioner
Содержание 2U14CS4ERA
Страница 10: ... Pinping diagrams Domestic air conditioner 4ˊPinping diagrams 8 ...
Страница 11: ... Operation range Domestic air conditioner 5ˊOperation range 9 ...
Страница 15: ...PCB 2 CN1 CN5 CN6 CN7 CN10 CN11 CN8 CN9 CN2 CN3 CN4 Domestic air conditioner Wiring diagram ...
Страница 16: ...0 Wiring diagram Domestic air conditioner ...
Страница 35: ...WARNING CAUTION Installations Domestic air conditioner 33 ...
Страница 36: ...Installations Domestic air conditioner 34 ...
Страница 37: ...Installations Domestic air conditioner 35 ...
Страница 38: ...Installations Domestic air conditioner 36 ...
Страница 39: ...Installations Domestic air conditioner 37 ...
Страница 40: ...Installations Domestic air conditioner 38 ...
Страница 41: ...Installations Domestic air conditioner 39 ...
Страница 85: ...1 Removal Procedure 1 Domestic Air Conditioner p ...
Страница 86: ...Loosen the top panel screws 1 2 Lift the top panel Removal Procedure 2 Domestic Air Conditioner ...
Страница 87: ...Loosen the screws and pull the panel Removal Procedure 3 Domestic Air Conditioner ...
Страница 89: ...Removal Procedure 5 Domestic Air Conditioner 2 ...
Страница 90: ...Removal Procedure 6 Domestic Air Conditioner 3 ...
Страница 91: ...2 Loosen the fixing screws and remove the motor Removal Procedure 7 Domestic Air Conditioner ...
Страница 92: ...Removal Procedure 8 Domestic Air Conditioner 4 F M P B ...
Страница 93: ...and remove the reactor Loosen the screw Removal Procedure 9 Domestic Air Conditioner ...
Страница 94: ...Loosen the marked screws and pull out the backgurd Removal Procedure 10 Domestic Air Conditioner 5 C H E 1 ...
Страница 96: ...4 Remove the compre ssor and pipe assay 5 Remove the conden ser Removal Procedure 12 Domestic Air Conditioner ...