Functions and control
7.1.5.3
˖
The protection function of AC current:
During the starting process of the compressor, if the AC current is greater than 12A, the frequency of the
compressor decreases at the speed of 1HZ/second.
During the starting process of the compressor, if the AC current is greater than 11A, the frequency of the
compressor decreases at the speed of 0.1HZ/second.
During the starting process of the compressor, if the AC current is greater than 10A, the frequency of the
compressor increases at the prohibited speed.
During the starting process of the compressor, if the AC current is greater than 9A, the frequency of the
compressor increases at the speed of no faster than 0.1HZ/second.
Remarks: when the outdoor temperature is high, there’s compensation for AC current protection.
Ł
When the outdoor environment temperature is higher than 40
ć
, AC current protection value decreases
by 1.5A
ł
When the outdoor environment temperature is higher than 50
ć
,AC current protection value decreases by
3.5A
Domestic air conditioner
19
7.1.5.2
˖
TC high temperature-preventing control of the indoor heating unit
Tpg_indoor is the highest value of the effective indoor unit (start it and it is in accord with the running state).
The indoor heat exchanger sensor tests the temperature of the indoor heat exchanger. If the temperature is
higher than 48
ć
, decrease the rotate speed of the compressor and do the high temperature-preventing
protection of the indoor heat exchanger; if the temperature of the indoor heat exchanger is lower than 45
ć
,
recover to the normal control.
TC The compressor stops
Fgh_t1
ˉ
2 Fgh_t1 63
ć
N Decreasing the frequency rapidly Fgh_t2 59
ć
Fgh_t2
ˉ
2 P Decreasing the frequency slowly
Fgh_t3 55
ć
Fgh_t3
ˉ
2 Q Prohibiting increasing the frequency
Fgh_t4 51
ć
Fgh_t4—2 R Increasing slowly Fgh_t5 47
ć
Fgh_t5—2
Normal
N
˖
Decreasing at the speed of 1HZ/1second
P
˖
Decreasing at the speed of 1Hz/10seconds
Q
˖
Continue to keep the last-time instruction cycle
R
˖
Increasing at the speed of 1Hz/10seconds
Remarks: the outdoor unit
Содержание 1U71SABFRA
Страница 11: ...Pinping diagrams Domestic air conditioner 4 Pinping diagrams Filter Filter ...
Страница 12: ...Operation range Domestic air conditioner 5 Operation range 10 0 20 16 32 10 20 15 10 ...
Страница 15: ...CN4 CN3 CN10 CN1 CN2 CN9 CN7 CN6 CN5 CN8 CN11 Connector Wiring Diagram Domestic Air Conditioner 13 PCB 2 ...
Страница 43: ...Seivice diagnosis Domestic air conditioner 41 ...
Страница 44: ...Seivice diagnosis Domestic air conditioner 42 ...
Страница 45: ...Seivice diagnosis Domestic air conditioner 43 ...
Страница 56: ...Circuit diagrams Domestic air conditioner 54 ...