Service Diagnosis
43
The outdoor mainboard is damaged
and needs be replaced
10.4.9 Overheat Protection for Discharge Temperature
Outdoor display: F4 LED1 flash 8 times
Check the control of the discharge temperature by the temperature detected by the
discharge pipe thermistor
When the compressor discharge temperature is above 110
℃
■ Electronic expansion valve defective
■ Faulty thermistor
■ Faulty PCB
* Caution: Be sure to turn off power switch before connect or disconnect connector
or else parts damage may be occurred.
Trouble
shooting
Supposed
Causes
Malfunction
Decision
Conditions
Method of
Malfunction
Detection
The temperature exceeds
110
℃
shortly after the
machine starts up?
The cryogen may have been leaked
during installation, or there may be
leakage in the piping system.
There may be other causes to make
the exhaust temperature too high.
Electrify the machine again and turn it on with
the remote control, then measure the
temperature at the exhaust temperature
sensor of the compressor on the outdoor unit
The results
deviate much?
The sensor is damaged. Replace
the sensor with a new one.
Malfunctions occur after running for
some time even though the measured
temperature is below 110
℃
. Pull out the
exhaust sensor and measure its
resistance at standard temperatures
according
to
the
resistance-
temperature table
YES
NO
YES
NO
Содержание 1U50KEPFRA-H
Страница 12: ...Operation range 5 Operation range 15 20 25 30 27 10 Domestic air conditioner 60 43 40 20 0 20 40 21 35...
Страница 14: ...Functions and control 13 Domestic air conditioner Wiring diagrams OUTDOOR UNIT...
Страница 54: ...Performance and curves diagrams 11 3 Cooling discharge pressure curves 54 Domestic air conditioner...
Страница 55: ...Performance and curves diagrams 11 4 Cooling suction pressure curves 55 Domestic air conditioner...
Страница 56: ...Performance and curves diagrams 11 5 Heating capacity temperature curves 56 Domestic air conditioner...
Страница 58: ...Performance and curves diagrams 11 7 Heating discharge pressure curves 58 Domestic air conditioner...
Страница 59: ...Performance and curves diagrams 11 8 Heating suction pressure curves 59 Domestic air conditioner...