14

Self-contained accessories

3. Accessories for installation

Name  of
Parts

No.

A

B

C

D

E

F

Non-adhesive

Tape

Adhesive

tape

Connecting

Hose

Gypsum

powder

Drain hose

Heat insulation

material

4. Choose the installation place

Install the indoor unit where the weight of the unit can be supported.

Install the indoor unit where the heat source and steam source are not close and the unit inletand outlet are not blocked.Install the indoor unit where the drainage is easy and the outdoor unit can be easily connected.Install the indoor unit where its cold air and hot air can be easily sent to all the corners of  theroom.Install the indoor unit where the power socket is near and there is sufficient space around the

indoor unit.

Install the indoor unit where there is no T.V set, radio set, and wireless appliance underneath,

and  the sunlight lamp is over one meter away.

If  the remote controller is installed on the wall, the indoor unit shall be ensured to receive thesignal while the sunlight lamp is on.

1. Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through tube

    purchased locally. The wall hole shall be with a outward down slope of at least 1/100. (See

    Figure 1)

2. Before drilling check that there is no pipe or reinforcing bar just behind the drilling position.

    Drilling shall avoid at positions with electric wire or pipe.

3. Mount the unit on a strong and horizontal building roof. If the base is not firm, it will cause

    noise, vibration or pipe broken and refrigerant leakage (see Figure 6).

4. Support the unit firmly.

5. Change the form of the connection pipe, connection wire and drain pipe so that they can go

     through the wall hole easily.

5. Installation procedure

Instructions to installation

Fig 1

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Содержание AD092XLERA

Страница 1: ...ON INSTALLATION MANUAL AD092XLERA AD122XLERA AD142XLERA AD182XLERA R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER No 0010577705 Please read this manual carefully before using this air conditioner Pleas...

Страница 2: ...afety precautions Notes for safety Parts and Functions Trouble shooting Customer Need to know When trouble happens Operation and Maintenance Failure code 1 2 3 5 6 7 8 9 10 11 12 23 24 25 http splitof...

Страница 3: ...fluorochlorichydrocarbon All th Consult your local authorities for the nameand address of the waste materialscollecting cente Safety Instructions and Warnings Before starting the air conditioner read...

Страница 4: ...pecifications The refrigerating circuit is leak proof The machine is adaptive in followingsituation 1 Applicable ambient temperature range 2 If the supply cord is damaged it must bereplaced by the man...

Страница 5: ...ay cause water leak electrical shock and fire hazard Don t put fingers or any other things into the inlet outlet and swing louver while theconditioner is in Because the highspeed fan is very dangerous...

Страница 6: ...use acci dents Pets and plants should not be blowed directly in the air flow Otherwise will suffer damage Don t operate the air conditioner with damp hands Otherwise will be shocked Only use correctly...

Страница 7: ...ating noise Air conditioner should be located in well vented and easily accessible place Air conditioner should not be located in thefollowing places a Places with machine oils or other oilva b Seasid...

Страница 8: ...e remote controller Never connect the earth wire with the gas pipe water pipe lightening arrester or phone line Never install the air conditioner where the flammable gas is easily leaked Do not spray...

Страница 9: ...Parts and Functions 7 INDOOR UNIT Electrical box Air inlet Drain pan Air outlet http splitoff ru tehn doc html...

Страница 10: ...rbed by indoor unit During operation white fog comes out of indoor unit When in COOL or DRY mode a thin water fog can be seen blown out of unit this is the condensed fog because the suddenly cooled in...

Страница 11: ...atically stops Water or vapor generated from the outdoor unit during heating This happens when the frost accumulated on the outdoor unit is removed during defrosting operation Defrosting operation Ple...

Страница 12: ...tallation please use the air conditioner according to the specification in the operation manual Using Directions Adjust suitable airflow direction Avoid direct sunlight and airflow Keep the proper ind...

Страница 13: ...he above mentioned items or when following phenomenon is observed stop the operation of the air conditioner and contact your sales dealer 1 The fuse or breaker often shuts down 2 Water drops off durin...

Страница 14: ...res Execute the installation accurately based on following the installation manual Again improper installations can result in water leakage electric shocks and fires When a large air conditioning syst...

Страница 15: ...angle 8 Pipe Expander Instructions to installation WARNING Its improper installation can also result in heat generation or fire When setting up or moving the location of the air conditioner do not mix...

Страница 16: ...unit shall be ensured to receive thesignal while t 1 Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall through tube purchased locally The wall hole shall be with a o...

Страница 17: ...unit a specially designed return air bellows shall be installed as shown in Figure 3 Figure 4 Figure 3 Figure 4 A Installing building roof Ceiling Air supply Air outlet duct Unit Return air Return ai...

Страница 18: ...rain piping of condensed water to keep warmth Figure 5 Figure 6 16 air return shutter air return duct sling dog drain piping transition air duct air outlet duct air diffuser joint of air diffuser M8 b...

Страница 19: ...ulation layer is needed for air supply and return duct First paste a glue nail to the air duct and then attach the insulation cotton that has a tinfoil layer and use the glue nail cover to fix Finally...

Страница 20: ...ause indoor water leakage CAUTION Requirements The indoor drain pipe shall be thermal insulated The connection part between the drain pipe and the indoor uni The drain pipe shall be slant downwards gr...

Страница 21: ...pipe Drain confirmation During trial run check that there is no leakage at the pipe connection part during water draining even in winter 19 Rigid PVC pipe VP31 5mm internal diameter Pipe Foamed PE wit...

Страница 22: ...LERA AD182XLERA Flare connection Gas pipe 3 way valve Indoor Unit Outdoor unit Liquid pipe 2 way valve Flare connection A To outdoor unit To gas pipe A adaptor from 9 52 to 12 7 6 35 mm 1 4 0 8 1 5 9...

Страница 23: ...the address must be 3 Indoor unit that connect to valve D the address must be 4 2 Installation check and trial operation Check the Layout of the Drain Pipe and Connection Wires and also the piping an...

Страница 24: ...ss it through the end ring of connecting line then connect it to the terminal block and tighten screw Wiring methods Ring Terminal T B Brazed seam B 8 0 9 0 mm d 4 3 5 3 mm T 1 0 2 0 mm For your refer...

Страница 25: ...F 3G 2 5 mm2 POSSIBLE REASONS Faulty temperature sensor Tai 01 Sensor disconnected or broken or at wrong position or short circuit Faulty temperature sensor Tc1 Sensor disconnected or broken or at wro...

Страница 26: ...ver current of the system or broken of the current sensor or malfunction with indoor or outdoor fan motors or faulty PCB 15 16 17 14 19 System high pressureprotection High pressure switch is disconnec...

Страница 27: ...26 Faulty sensor Toci Sensor disconnected or broken or short circuit 2A Low voltage protection VDC 194V too low voltage from power source High voltage protection VDC 400V too high voltage from power...

Страница 28: ...ROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266555 P R China Web Site http www haier com http splitoff ru tehn d...

Отзывы: