background image

                                                                                                                                               

          Service diagnosis

 

               

Domestic air conditioner

8.3  Problem Symptoms and Measures 

Symptom 

Check Item 

Details of Measure 

None of the units 
operates

Check the power supply. 

Check to make sure that the rated voltage is supplied. 

Check the indoor PCB 

Check to make sure that the indoor PCB is broken 

Operation 
sometimes stops. 

Check the power supply. 

A power failure of 2 to 10 cycles can stop air conditioner 
operation. 

Equipment 

operates but 

does not cool, or 

does not heat 

(only for heat 

pump) 

Check for faulty operation 
of the electronic 
expansion valve. 

Set the units to cooling operation, and compare the 
temperatures of the liquid side connection pipes of the 
connection section among rooms to check the opening and 
closing operation of the electronic expansion valves of the 
individual units. 

Diagnosis by service port 
pressure and operating 
current. 

Check for insufficient gas. 

Large operating 

noise and 

vibrations 

Check the installation 

condition. 

Check to make sure that the required spaces for 

installation (specified in the Technical Guide, etc.) are 

provided. 

14

Содержание 1U09DR4EAA

Страница 1: ...ngers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or Repair the product or pro...

Страница 2: ...onditioner Contents 1 Introduction 1 2 Specifications 7 3 Piping diagrams 9 4 Operation range 10 6 Dimensional drawings 7 Center of gravity 8 Service Diagnosis 5 Circuit diagrams 13 12 12 11 9 Perform...

Страница 3: ...l name explanation 1 U 0 9 D R 4 E A A The maximum combination number Type of outdoor unit U normal type Nominal cooling capacity 9000BTU h Platform of outdoor units D Platform Version number Heat pum...

Страница 4: ...fore disassembling the equipment for a repair Working on the equipment that is connected to a power supply can cause an electrical shook If it is necessary to supply power to the equipment to conduct...

Страница 5: ...ng the welder in an enclosed room can cause oxygen deficiency 1 2 2 Cautions Regarding Products after Repair Warning Be sure to use parts listed in the service parts list of the applicable model and a...

Страница 6: ...eneration or fire Do not damage or modify the power cable Damaged or modified power cable can cause an electrical shock or fire Placing heavy items on the power cable and heating or pulling the power...

Страница 7: ...perly water can enter the room and wet the furniture and floor 1 2 3 Inspection after Repair Warning Check to make sure that the power cable plug is not dirty or loose then insert the plug into a powe...

Страница 8: ...Be sure to check the drainage of the indoor unit after the repair Faulty drainage can cause the water to enter the room and wet the furniture and floor 1 2 4 Using Icons Icons are used to attract the...

Страница 9: ...n Rated KW 1 6 3 W W P O C R E E h m l a v o m e R e r u t s i o M TECHNICAL SPECIFICATIONS UNIT Dimensions H W D mm 660 275 540 Packaged Dimensions H W D mm 802 373 595 6 2 G K t h g i e W 9 2 G K t...

Страница 10: ...rant type R410a Refrigerant charge KG 0 68 Maximum allowable distance between indoor and outdoor m 15 Maximum allowable level difference m 10 Refrigerant control Capillary Piping connections external...

Страница 11: ...Piping diagrams Domestic air conditioner 3 Piping diagrams 9...

Страница 12: ...Operation range Domestic air conditioner 4 Operation range 10...

Страница 13: ...TE BL BLUE FAN MOTOR 2 There are no dotted lines on cool only type marked with Wire is connected from 4 marked with on terminal block to 1 TO INDOOR FRESH AIR MOTOR 4 way valve CAPACITOR CAPACITOR 1 S...

Страница 14: ...Dimensinal drawings Domestic air conditioner 6 Dimensional drawings 7 Center of gravity 12 660 540 275 275 660 255 2 540 660 275 8 3 unit mm unit mm...

Страница 15: ...ion error occurs between the indoor and outdoor units In either case conduct the diagnostic procedure described in the following pages 8 2 Parameter of primary electronic appliance 13 NO Name Paramete...

Страница 16: ...s but does not cool or does not heat only for heat pump Check for faulty operation of the electronic expansion valve Set the units to cooling operation and compare the temperatures of the liquid side...

Страница 17: ...ote The values vary slightly in some models Faulty connector connection Faulty thermistor Faulty PCB Caution Be sure to turn off power switch before connect or disconnect connector or else parts damag...

Страница 18: ...d to determine MCU When the data of EEPROM is error or the EEPROM is damaged Faulty EEPROM data Faulty EEPROM Faulty PCB Caution Be sure to turn off power switch before connect or disconnect connector...

Страница 19: ...r else parts damage may be occurred Service diagnosis 17 Method of Malfunction Detection Malfunction Detection Conditions Supposed Causes Yes Troubleshooting Check whether terminals on indoor pcb is w...

Страница 20: ...Performance Curves Diagram Domestic air conditioner 9 Performance Curves Diagram 9 1 Cooling capacity temperature curves 18...

Страница 21: ...Performance Curves Diagram Domestic air conditioner 19 9 2 heating capacity temp curves...

Страница 22: ...Domestic air conditioner 20 9 3 Cooling power consumption temp curves Performance Curves Diagram...

Страница 23: ...Domestic air conditioner 9 4 heating power consumption temp curves 21 Performance Curves Diagram...

Страница 24: ...tic air conditioner Sincere Forever Haier Group Haier Industrial Park No 1 Haier Road 266101 Qingdao China_ Http www haier com Edited by Signed by Approved by Wang Fang Yang Xiaodong He shiquan Wu Hon...

Отзывы: