QUICK-REFERENCE SETUP GUIDE 
 
This table displays each Installer Setup item with its default setting.  The column labeled "CURRENT" can be 
used to write down the current settings if any changes are made to the default settings. 
 

Item Number 

Description 

Default  

Current 

 00  

Address 

 

 01  

Communication mode 

 

 02  

System options 

 

 03  

Display options 

 

 04  

Calibration offset 

30 

 

 05  

Cool setpoint limit 

51 

 

 06  

Heat setpoint limit 

91 

 

 07  

Not used 

 

 08  

Not used 

 

 09  

Cooling anticipator 

 

 10  

Heating anticipator 

 

 11  

Cooling minimum on/off time 

 

 12  

Heating minimum on/off time 

 

 13  

Not used 

 

 14  

Clock adjust 

30 

 

 15  

Filter reminder 

10 

 

 16  

System runtime (This week) 

 

 17  

System runtime (Last week) 

 

 
 
REMOTE SYSTEM WIRING DIAGRAMS 
 
This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star 
program.  When used with remote systems, HAI recommends that the thermostat be configured as "non-
programmable" (See Setup Item 03 - "Display Options"). 

 

 
HAI AUTOMATION SYSTEMS
 
 
The thermostat can be connected to an HAI automation system.  The controller can send commands to the 
thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items. 
 
Run a 3 (or 4) conductor wire from the HAI system to the thermostat location.  All thermostats on an Omni, 
Omni II, OmniPro, or OmniPro II controller are connected to Zone 16 and Output 8.   
 
All thermostats on an OmniLT controller are connected to the GRN (Green), BLK (Black), and YEL (Yellow) 
terminals in the section marked "TSTAT". 
 
Connect the red COMM cable wire with the black COMM cable wire.  Make the connections (as shown in 
Figure 10)
 using the supplied wire splices.   

Содержание RC-80 Omnistat

Страница 1: ...country in which this equipment is to be installed INSTALLATION Before installing this thermostat 1 Read all of the installation instructions carefully 2 Read the Owner s Manual carefully 3 Ensure th...

Страница 2: ...TING When mounting the RC 80 grasp the thermostat by the sides avoiding the keys and unsnap the base from the face Holding the base to the wall so that the word TOP is upright and facing you 1 Mark th...

Страница 3: ...tion See Figures 10 11 Insert the cable into the connector on the thermostat circuit board marked COMM Upon completion of wiring the thermostat push all excess wiring into the hole in the wall Plug th...

Страница 4: ...ok up to live circuits An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat Figure 4 Thermostat power up for test or demonstration purposes Note...

Страница 5: ...ons Figure 6 Single stage cool only thermostat Common wire is required to use the display backlight in the RC 80B Also use if heat cool or fan relay cannot supply 15mA to power thermostat without acti...

Страница 6: ...mper to the TIMED position between the middle and left pin on the connector See Figure 9 2 To configure the display backlight to always be on set the JP2 Select Backlight Mode jumper to the ON positio...

Страница 7: ...ter unit comes on Set the mode to OFF Ensure that the heat goes off 6 Set the Mode to COOL Use the down arrow key to lower the desired temperature setting below the current temperature Ensure that the...

Страница 8: ...e of the item number 3 Press the Prog key to advance to the next item 4 Press the Hold key to return to the previous item 5 Use the arrow keys to change the value of each item 6 Do not set the values...

Страница 9: ...ns 0 Auto changeover no fan with heat 1 Auto changeover fan on with heat 4 Manual changeover no fan with heat 5 Manual changeover fan on with heat 12 Heat only no fan with heat 13 Heat only fan on wit...

Страница 10: ...6 Heat setpoint limit This item is used to limit the temperature setting in heat mode The desired heat setting can never be set above this setting The default setting is 91 07 Not used 08 Not used 09...

Страница 11: ...is slower as are most radiant heating systems a higher number will help maintain an even space temperature The default setting is 4 11 Cooling minimum on off time minutes This item is used to limit t...

Страница 12: ...t of time the system fan has been running When this setting reaches 0 the thermostat will display a reminder to replace the filter The setting is the amount of days 24 hours of system operation before...

Страница 13: ...thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star program When used with remote systems HAI recommends that the thermostat be configured as non progra...

Страница 14: ...14 4 Note Do not connect the red COMM cable wire to 12V Figure 10 Hookup to an HAI system Additional thermostats are connected in parallel They may be connected in home run or daisy chain configuratio...

Страница 15: ...be set to 24 Run a two conductor wire from the remote system or remote switch to the thermostat location Make the connections using supplied wire splices See Figure 11 Red and yellow wires are not us...

Страница 16: ...at keys for test remove jumper SYMPTOM ACTION TO TAKE 1 Check COMM connector and wiring 2 Check thermostat address setting 3 Check communications mode setting Control By Remote System Not Working 4 Ch...

Отзывы: