HAI OMNISTAT RC-122BZ Скачать руководство пользователя страница 15

1

1

5

5

 

TROUBLESHOOTING TIPS 

 

 
 
 

SYMPTOM

 

ACTION TO TAKE

 

1.

 

Check power to the thermostat 

2.

 

Check wiring diagrams 

Thermostat Dead 

3.

 

Check thermostat temperature sensor 

Thermostat will not operate with a damaged temperature sensor 

 

SYMPTOM

 

ACTION TO TAKE

 

1.

 

Check for break in G, W, or Y wire 

2.

 

Allow minimum off time to pass 

3.

 

Check system options for correct settings 

Fan, Heat, Or Cool 
Inoperative 

4.

 

Remote system is overriding thermostat 

"REMOTE"

 is displayed when system is overriding thermostat. 

 

SYMPTOM

 

ACTION TO TAKE

 

1.

 

Mode is Off  (Select Heat, Cool, or Auto) 

Can't Adjust Temperature 

2.

 

Check if thermostat keys are disabled 

To enable thermostat keys for test, remove jumper 

 

SYMPTOM

 

ACTION TO TAKE

 

 1.  Check Node ID 
  2.  Check communications mode setting 

Control By Remote System 
Not Working 

  3.  Check setup of the remote system 

 

Ensure that all setup items for the thermostat and the remote system  

are set to the proper configurations for communication 

SYMPTOM

 

ACTION TO TAKE

 

1.

 

Allow 30 minutes for thermostat to adjust to room 

temperature 

2.

 

Adjust calibration offset 

Temperature Reading 
Incorrect 

3.

 

Change setup option to display oF or oC 

After installation, allow the thermostat up to 30 minutes for an accurate temperature reading 

 

SYMPTOM

 

ACTION TO TAKE

 

Display Problem 

1.

 

Disconnect power to the thermostat.  Reconnect, then 

observe display self-test 

 

For a 5 second period after power is reconnected, all segments  

of the display should light indicating all thermostat functions 

Содержание OMNISTAT RC-122BZ

Страница 1: ...acceptable in the country in which this equipment is to be installed INSTALLATION Before installing this thermostat 1 Read all of the installation instructions carefully 2 Read the Owner s Manual care...

Страница 2: ...NG When mounting the RC 122BZ grasp the thermostat by the sides avoiding the keys and unsnap the base from the face Holding the base to the wall so that the word TOP is upright and facing you 1 Mark t...

Страница 3: ...tat push all excess wiring into the hole in the wall Plug the hole with the supplied insulating foam to ensure an accurate temperature reading by the thermostat Align the tabs of the thermostat face w...

Страница 4: ...system The display will show all segments for about 5 seconds 3 Press the Fan key The fan should come on Press the Fan key again The fan should go off 4 Press Hold to override Energy Efficient Contro...

Страница 5: ...5 5 Figure 5...

Страница 6: ...6 2 To configure the display backlight to always be on set the JP2 Select Backlight Mode jumper to the ON position between the middle and bottom pin on the connector See Figure 6 3 To configure the di...

Страница 7: ...s item 5 Use the arrow keys to change the value of each item 6 Do not set the values to anything other than the specified range for each item 7 To exit Setup mode press the Fan key The thermostat will...

Страница 8: ...cient Control EEC should be turned on settings 0 1 4 and 5 If the system is equipped with a highly efficient second stage you may want to turn EEC off settings 8 9 12 and 13 The thermostat will act li...

Страница 9: ...t setting is 51 06 Heat setpoint limit This item is used to limit the temperature setting in heat mode The desired heat setting can never be set above this setting The default setting is 91 07 Not use...

Страница 10: ...t is running faster or slower than the actual time you can have the thermostat automatically compensate up to 29 seconds per day The thermostat will add or subtract the selected amount of time daily 1...

Страница 11: ...he thermostat QUICK REFERENCE SETUP GUIDE This table displays each Installer Setup item with its default setting The column labeled CURRENT can be used to write down the current settings if any change...

Страница 12: ...ry or inclusion controller to exclude the thermostat from the network press and release the Hold button on the thermostat This will exclude the thermostat from the Z Wave network The thermostat suppor...

Страница 13: ...LASS_THERMOSTAT_FAN_STATE Upon power up allow 10 seconds for the RC 122BZ thermostat to initialize After 10 seconds a controller can request the state of the fan COMMAND_CLASS_THERMOSTAT_OPERATING_STA...

Страница 14: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency...

Страница 15: ...stat keys for test remove jumper SYMPTOM ACTION TO TAKE 1 Check Node ID 2 Check communications mode setting Control By Remote System Not Working 3 Check setup of the remote system Ensure that all setu...

Страница 16: ...d due to severe weather Stage 2 On Too Often 2 EEC is disabled SYMPTOM ACTION TO TAKE 1 System may be equipped with an outdoor thermostat which is overriding Stage 2 the when outdoor temperature is mi...

Отзывы: