HAI OMNISTAT RC-122BZ Скачать руководство пользователя страница 12

1

1

2

2

 

WIRELESS COMMUNICATIONS WITH HAI CONTROLLER 

 
This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star 
program.  When used with remote systems, HAI recommends that the thermostat be configured as "non-
programmable" (See Setup Item 03 - "Display Options"). 
 

HAI AUTOMATION SYSTEMS 

 
The thermostat can communicate with an HAI automation system over a Z-Wave network.  The controller can 
send commands to the thermostat to change mode, cool setting, heat setting, status of fan and hold, and other 
items. 
 

ADDING A THERMOSTAT TO THE Z-WAVE NETWORK 

 
When prompted by Z-Wave primary or inclusion controller to include the thermostat to the network, press and 
release the ‘Hold’ button on the thermostat.  This will include the thermostat on the Z-Wave network. 
 

REMOVING A THERMOSTAT FROM THE Z-WAVE NETWORK  

 
When prompted by Z-Wave primary or inclusion controller to exclude the thermostat from the network, press 
and release the ‘Hold’ button on the thermostat.  This will exclude the thermostat from the Z-Wave network. 
  
The thermostat supports the following command classes: 
 
COMMAND_CLASS_THERMOSTAT_MODE 
COMMAND_CLASS_THERMOSTAT_SETPOINT 
COMMAND_CLASS_THERMOSTAT_FAN_MODE 
COMMAND_CLASS_THERMOSTAT_FAN_STATE 
COMMAND_CLASS_THERMOSTAT¬_OPERATING_STATE 
COMMAND_CLASS_SENSOR_MULTILEVEL 
COMMAND_CLASS_ASSOCIATION 
COMMAND_CLASS_CONFIGURATION 
COMMAND_CLASS_VERSION 
COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_SWITCH_BINARY 
COMMAND_CLASS_CLOCK 
 

COMMAND_CLASS_THERMOSTAT_MODE 

 
Upon power up, allow 10 seconds for the RC-122BZ thermostat to initialize.  After 10 seconds, a controller can 
set the mode, get the current mode, and get the modes supported by the thermostat. 
 

COMMAND_CLASS_THERMOSTAT_SETPOINT 

 
Upon power up, allow 10 seconds for the RC-122BZ thermostat to initialize.  After 10 seconds, a controller can 
change setpoints, get current setpoints, and request the setpoints that are supported by thermostat. 
 

Содержание OMNISTAT RC-122BZ

Страница 1: ...acceptable in the country in which this equipment is to be installed INSTALLATION Before installing this thermostat 1 Read all of the installation instructions carefully 2 Read the Owner s Manual care...

Страница 2: ...NG When mounting the RC 122BZ grasp the thermostat by the sides avoiding the keys and unsnap the base from the face Holding the base to the wall so that the word TOP is upright and facing you 1 Mark t...

Страница 3: ...tat push all excess wiring into the hole in the wall Plug the hole with the supplied insulating foam to ensure an accurate temperature reading by the thermostat Align the tabs of the thermostat face w...

Страница 4: ...system The display will show all segments for about 5 seconds 3 Press the Fan key The fan should come on Press the Fan key again The fan should go off 4 Press Hold to override Energy Efficient Contro...

Страница 5: ...5 5 Figure 5...

Страница 6: ...6 2 To configure the display backlight to always be on set the JP2 Select Backlight Mode jumper to the ON position between the middle and bottom pin on the connector See Figure 6 3 To configure the di...

Страница 7: ...s item 5 Use the arrow keys to change the value of each item 6 Do not set the values to anything other than the specified range for each item 7 To exit Setup mode press the Fan key The thermostat will...

Страница 8: ...cient Control EEC should be turned on settings 0 1 4 and 5 If the system is equipped with a highly efficient second stage you may want to turn EEC off settings 8 9 12 and 13 The thermostat will act li...

Страница 9: ...t setting is 51 06 Heat setpoint limit This item is used to limit the temperature setting in heat mode The desired heat setting can never be set above this setting The default setting is 91 07 Not use...

Страница 10: ...t is running faster or slower than the actual time you can have the thermostat automatically compensate up to 29 seconds per day The thermostat will add or subtract the selected amount of time daily 1...

Страница 11: ...he thermostat QUICK REFERENCE SETUP GUIDE This table displays each Installer Setup item with its default setting The column labeled CURRENT can be used to write down the current settings if any change...

Страница 12: ...ry or inclusion controller to exclude the thermostat from the network press and release the Hold button on the thermostat This will exclude the thermostat from the Z Wave network The thermostat suppor...

Страница 13: ...LASS_THERMOSTAT_FAN_STATE Upon power up allow 10 seconds for the RC 122BZ thermostat to initialize After 10 seconds a controller can request the state of the fan COMMAND_CLASS_THERMOSTAT_OPERATING_STA...

Страница 14: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency...

Страница 15: ...stat keys for test remove jumper SYMPTOM ACTION TO TAKE 1 Check Node ID 2 Check communications mode setting Control By Remote System Not Working 3 Check setup of the remote system Ensure that all setu...

Страница 16: ...d due to severe weather Stage 2 On Too Often 2 EEC is disabled SYMPTOM ACTION TO TAKE 1 System may be equipped with an outdoor thermostat which is overriding Stage 2 the when outdoor temperature is mi...

Отзывы: