Page 4
JUMPER SETTINGS
The serial interface is one of several expansion boards available for HAI controllers. A controller can have up to 4 expansion boards.
Each board has a jumper labeled ADDR for address. The jumper setting determines the address of each board. Each board must have
its own address. Then the controller can be configured to determine what type of expander is at each address. The jumpers on the
expander boards should be set as follows:
Model 10A06 Hardwire Expander - Set jumper to 1 (factory default)
Model 10A17 Serial Interace
- Set jumper to 3 for first serial interface (factory default)
- Move jumper to 4 for second serial interface (Aegis and OmniPro V. 1.6 or later)
The jumper settings marked as factory default are the settings shipped from the factory.
CONTROLLER SET UP FOR MODEL 10A17 SERIAL INTERFACE
The serial interface must be enabled in the controller software. A new Installer Set Up Item has been added to configure the
expansion modules on the controller.
If a serial interface board is being installed in an existing system with one or more expander boards, make a note of the jumper settings
and type of each expander board and verify that the module type is set properly for each module.
To enter the installer SETUP menu, press 8 (or 9 depending on model and firmware version), enter the installer code (default is 1111),
then press # for the installer menu.
I NSTALLER SETUP
1=CTRL 2=ZONE 3=DCM
↓
4=AREA 5=TEMP 6=MISC
7=EXP
↑
To configure Module Types, press the 7 (EXP) key. The following items are shown.
MODULE 1 TYPE
The Module Type defines the function of each expander board on the controller. Module 1 is the module with the ADDR jumper set
to 1. Set the module type from the list below. Press # to change the module type, then use the arrow keys to select the proper module
type, then press # to enter.
Select from the following for the module with jumper set to 1:
MODULE TYPES
NUMBER
DESCRIPTION
NOT USED
0
No module is installed
HARDWIRE EXPNDR
1
Model 10A06 Hardwire Expander is installed
OMNI-LINK
3
Model 10A17 Serial Interface using Omni-Link protocol
PRO-LINK
4
Model 10A17 Serial Interface using Pro-Link protocol (Aegis and OmniPro)
MODULE 2 TYPE through MODULE 4 TYPE
Module 2 is the module with the jumper set to 2, and so on. Set the module type for each module as shown above.