background image

8

Hague Filter Owner's Manual

1

DAYS BETWEEN REGEN

SET

3

2

REGEN TIME HOUR

AM

SET

12:00

3

REGEN TIME MINUTES

AM

SET

12:00

4

LIGHT NORMALLY

SET

ON

5

Return to general display.

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

TIME OF DAY

MON

GPM

2:40

8

PM

Typically, time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an extended 

power outage occurs, the time of day will flash on and off indicating that the time should be reset . To set the clock:

STEP 1 –

 Press the 

CLOCK

 button .

STEP 2 –

  Set the hour of the day using 

UP 

or 

DOWN

 buttons . AM/PM toggles after 12 . Press 

NEXT 

to go to step 3 .

STEP 3 –

   Set the minutes using 

UP

 or 

DOWN

 buttons . Press 

NEXT

 to go to step 4 or 

REGEN

 to return to previous step . 

STEP 4 –

  Set the day of the week using 

UP

 or 

DOWN

 buttons . Press 

NEXT

 to exit clock setting or 

REGEN

 to return to previous step . 

1. Set Time of Day

1

TIME

HOUR

AM

SET

2:00

TIME

MINUTES

AM

SET

2:00

2

3

CURRENT DAY

SET

MON

4

return to general display

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

TIME OF DAY

MON

GPM

2:40

8

PM

Press 

NEXT

 to cycle to the next step or 

REGEN

 to return to the previous step . 

STEP 1

 – Press and hold the 

NEXT

 and 

UP

 buttons simultaneously for 3 seconds .

  

STEP 2

 – 

DAYS BETWEEN REGENERATION (DAY OVERRIDE): 

Use the 

UP

 or 

DOWN

 buttons to adjust the day 

override . Adjustable from 1-28 days or OFF . The manufacturer has factory set 3 days as the default .
The Day Override value represents the maximum number of days between regenerations . If any number 

is set (1-28 days), a regeneration will be scheduled for that day if the gallon capacity has not been met .  If 

OFF is set, the unit will only initiate a regeneration once the gallon capacity has been met . 

STEP 3

 –  

REGENERATION HOUR: 

Use the 

UP

 or 

DOWN

 buttons to adjust the time of day the unit will 

regenerate . AM/PM toggles after 12 . The manufacturer has factory set 12:00 A .M . as the default setting 

which is recommended for a normal household . 

STEP 4

 – 

 REGENERATION  MINUTES:

 

Use the 

UP

 or 

DOWN

 buttons to set minutes . 

STEP 5

 – 

 BACKLIGHT DISPLAY CONTROL: 

Use the 

UP

 or 

DOWN

 buttons to turn the backlight setting ON or OFF . 

If unit is set to OFF, the backlight will turn off after 5 minutes of inactivity . 

This setting is not available on 

all models. 

 

Press 

NEXT

 to return to General Display .

2. Programming

Programming Procedures

Содержание HFAIR-1054

Страница 1: ...lter Iron and Sulfur Air Draw Filters OWNER S MANUAL AND INSTALLATION GUIDE For Models HFFE 1054 HFFE 1354 HFHS 1054 HFHS 1354 HFAIR 1054 HFAIR 1354 100037741 100037742 100037739 100037740 100037743 1...

Страница 2: ...rranty 26 Quick Reference Guide 27 YOUR WATER TEST Hardness______________________ gpg Iron___________________________ ppm pH____________________________ number Nitrates_______________________ ppm Mang...

Страница 3: ...and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operating screen will cycle through...

Страница 4: ...er flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Страница 5: ...subjected to room temperatures under 33 F 4 Do not subject the tank to any vacuum as this may cause an implosion and could result in leaking If there is a possibility a vacuum could occur please make...

Страница 6: ...o a subsurface drainage system or other safe location Remember to follow all local codes When installing the drain line on any backwashing filter especially filters that utilize air as the regenerant...

Страница 7: ...is necessary to relieve the pressure from the system Place filter into by pass mode Fig 2 Page 4 and release pressure by manually stepping through an entire regeneration sequence This will adequately...

Страница 8: ...REGEN UP DOWN NEXT CLOCK REGEN UP DOWN NEXT CLOCK TIME OF DAY MON GPM 2 40 8 PM Press NEXT to cycle to the next step or REGEN to return to the previous step STEP 1 Press and hold the NEXT and UP butt...

Страница 9: ...ing steadily to the drain clear and without the presence of air slowly open the inlet valve Restore power and momentarily press the button to advance the control to the REGENERANT DRAW DOWN position 4...

Страница 10: ...is installed GPM flashes on the display when water is being treated indicating gallons per minute flowing through the system 2 REGENERATION MODE Typically a system is set to regenerate at a time of no...

Страница 11: ...ERROR appears and flashes alternately with the dealer name and phone number record the ERROR number and contact your servicing dealer promptly This indicates that the control valve was not able to fu...

Страница 12: ...TER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are...

Страница 13: ...el in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Cont...

Страница 14: ...osition or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and...

Страница 15: ...GEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP mot...

Страница 16: ...losed The alarm buzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or discon...

Страница 17: ...o Part No Description Qty 1 CV4381 01 Hague Filter Cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV4377WF WF Replacement Board 1 5 CV3110 Drive gear 12 x 36 3 6 CV310...

Страница 18: ...V3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3001 1 body assembly downflow 1 CV3001UP 1 body assembly...

Страница 19: ...1 CHECK VALVE ASSEMBLY Item No Part No Description Qty 1 CH4642 WR A Air check valve assembly 1 Although no tools are necessary to assemble or disassemble the valve the Service Wrench shown in variou...

Страница 20: ...V3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown CV3170 O ri...

Страница 21: ...08 04 FTG Drain 1 Strt No Sil 1 Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elbow l...

Страница 22: ...Part No Description Qty 1 OZ1 A Ozone Kit Assembly 1 2 OZ1 CASE Enclosure Top Bottom and Clip cover not shown 1 3 33217 WRP3 Ozone Cell 1 not shown CJCPG 6PBLK 3 8 Compression Nut 1 not shown CH4642WR...

Страница 23: ...OLVENT Item Part No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628...

Страница 24: ...24 Hague Filter Owner s Manual This page intentionally left blank...

Страница 25: ...1 0 1 0 pH Range 6 8 to 9 0 6 8 to 9 0 Total Dimensions 10 W x 52 H 13 W x 62 H Weight Filled Lbs 106 5 164 Sulfur Filters Iron Air Filters 1 Op onal Ozone Generator not recommended for use on lters...

Страница 26: ...d is owned by the original owner This warranty does not cover expendable or misapplied medias or damages due to accident re ood freezing or any other Act of God We are not responsible for damages due...

Страница 27: ...DOWN buttons AM PM toggles at 12 3 Press 4 Adjust minutes with UP and DOWN buttons 5 Press 6 Adjust current day with UP and DOWN buttons 7 Press to complete and return to normal operation CURRENT DAY...

Страница 28: ...100037746 RevA0120 Iron and Sulfur Air Draw Filter Hague Quality Water Int l 4343 South Hamilton Road Groveport OH 43125 Phone 614 836 2115 Fax 614 836 5349...

Отзывы: