WQA–Performance Data Sheet 

Our H3000 and H3500 Reverse Osmosis Drinking Water Appliances have been 
tested and conform to NSF/ANSI Standard 58. The water treatment 
performance for specific claims are substantiated and verified by the “Reduction 
Performance” test data listed below. The concentration of the indicated 
substances in water entering the appliances was reduced to a concentration 
less than or equal to permissible limits for water leaving the appliance, as 
specified in NSF/ANSI 58. While testing was performed under standard 
laboratory conditions actual performance may vary. H3000 and H3500 are 
certified by WQA to NSF/ANSI 58. 

Reduction Performance 

Model H3000 (P/N 3146U) 

Contaminant 

ICC

2

 mg/L 

MPWC

3

mg/L

Average % 

Rejection 

Arsenic (+5) † 

0.050±10% 0.010 

99.3 

Barium* 10.0±10% 

2.0 

99.8 

Cadmium* 0.03±10% 

0.005 

99.0 

Chromium (3)* 

0.30±10% 

0.05 

99.7 

Chromium (6)* 

0.30±10% 

0.05 

99.2 

Cysts** Min.50,000/mL 

99.95% 99.98% 

Fluoride

8.0±10% 1.5 

97.0 

Lead

0.15±10% 0.010 

99.4 

Nitrate-N*1 27±10%  10.0 

94.3 

Nitrite-N*1 3.0±10% 1.0 

82.1 

Selenium

0.10±10% 0.05 

94.0 

TDS

750±40 mg/L 187

96.7 

Reduction Performance 

Model H3500 (P/N 2246 U) 

Contaminant 

ICC

2

 mg/L 

MPWC

3

mg/L

Average % 

Rejection 

Arsenic (+5)† 

0.050±10% 0.010 

99.3 

Barium* 10.0±10% 

2.0 

99.8 

Cadmium* 0.03±10% 

0.005 

99.0 

Chromium (3)* 

0.30±10% 

0.1 

99.7 

Chromium (6)* 

0.30 ±10% 

0.1 

99.2 

Cysts** Min.50,000/mL 99.95% 

99.99 

Fluoride

8.0±10% 1.5 

97.0 

Lead

0.15±10% 0.010 

99.4 

Nitrate-N*1 27±10%  10.0 

94.3 

Nitrite-N*1 3.0±10% 

 

1.0 

82.1 

Selenium

0.10±10% 0.05 

94.0 

TDS

750±40 mg/L 187

96.2 

2

 Influent Challenge Concentration 

3

 Maximum Permissible Water Concentration 

Performance Data Sheet 

Reverse Osmosis / Activated Carbon Drinking Water Appliance 

4343 South Hamilton Rd. 
Groveport, OH 43125 614-836-2115 

Test Parameters 

pH

7.5±0.5 

TDS

200-500 mg/L 

Temperature 77±2°F 

25±1°C 

Turbidity 

 1 NTU 

Pressure 50±3 

psig 

* This contaminant was tested at 750 mg/L ±40 mg/L TDS. 
** This appliance may be used on disinfected water that may contain filterable cysts. 

1

 This appliance is acceptable for treatment of Nitrate / Nitrite with influent 

concentrations of no more than 27 mg/L of nitrate and 3 mg/L of nitrite combined 
measured as N and is certified for nitrate/nitrite reduction only for water sources with a 
water pressure of 40 psig or greater.  

† This appliance has been tested for the treatment of water containing pentavalent 
arsenic (also known as As(V), As(+5), or arsenate) at concentrations of 0.30 mg/L or 
less. This appliance reduces pentavalent arsenic, but may not remove other forms of 
arsenic. This appliance is to be used on water supplies containing a detectable free 
chlorine residual at the appliance inlet or on water supplies that have been 
demonstrated to contain only pentavalent arsenic. Treatment with chloramine 
(combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic 
to pentavalent arsenic. Please see the Arsenic Facts section.  

WARNING!

 These appliances must not be installed where the water source is 

microbiologically unsafe or of unknown quality without adequate disinfection before 
and/or after the appliance! A water source that is not potable relative to waterborne 
pathogens voids the warranty. 

Operational maintenance and replacement requirements are essential for these 

appliances to perform to specification as advertised. 

FACTORS WHICH AFFECT THE LIFETIME AND  

PERFORMANCE OF YOUR WATERMAX

®

 RO 

1. TYPE OF MEMBRANE: 

Cellulose Tri-Acetate (CTA): Up to 1,200 PPM TDS with 

pressure of at least 40 PSI. Chlorine Tolerant- Some bacteria resistance- 5.0 to 9.0 
pH- Excellent production rate- For use only with a chlorinated water supply. 

Thin-Film Composite (TFC): Up to 2,000 PPM TDS with pressure of at least 40 PSI. 
Not chlorine tolerant- Bacteria resistant- 4.0 to 11.0 pH- Most advanced thin-film 
composite, non-cellulosic- Chemically stable- Highest production rate. 

2. SQUARE FEET OF MEMBRANE: 

The square feet of membrane and the production

of RO water are in direct proportions. 

3. WATER PRESSURE:

 The higher the net pressure across the membrane, the greater 

the quantity of RO water. A minimum pressure of 40 PSI is recommended. 

4. TOTAL DISSOLVED SOLIDS:

 The higher the TDS, the lower the production. Each 

100 PPM represents about one PSI reduced pressure on the membrane. Thus, 
1,000 PPM reduces the effective net pressure by 10 PSI.  

5. WATER TEMPERATURE: 

Colder water results in lower production. Temperatures

above 85 degrees F are to be avoided because of problems with the membrane 
support structures and accelerated compaction rates of CTA membranes. TFC may 
be used at temperatures up to 113 degrees F.  

6. SURFACE COATING OR FOULING:

 A neglected pre-filter can allow sediment to 

accumulate on the cartridge surface and impair the necessary flow of water through 
the filter, thus reducing membrane life. Also, salts can precipitate on the membrane, 
plugging the pores and channels. A water softener or other types of pre-treatment 
installed before the RO appliance significantly reduces this load and extends 
membrane life. 

Our Reverse Osmosis Drinking Water appliances contain replaceable treatment components, critical for the effective reduction of Total Dissolved Solids as well as 
inorganic contaminants. Each appliance will have some or all of the following replacement service components: Sediment pre-filter, sediment/carbon block pre-filter 
( H3500 only ), activated carbon pre-filter, prolonged contact filter, activated carbon post-filter, flow restrictor and the membrane. (Please see replacement element 
diagrams on reverse side.) The life expectancy of these components will vary from one water source to another. Therefore, we recommend that you, the user, have 
the water tested every six months to maintain acceptable water quality. Operational, maintenance and replacement requirements are essential for these appliances 
to perform to specification. To maintain the highest quality water, we recommend draining the storage tank every week. Ask your dealer about maintenance 
programs or monitoring devices for any of our drinking water appliances.  

WaterMax RO Owner’s Manual 

11/11/2009

10

Содержание WATERMAX LC100P

Страница 1: ...ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E M MO OD DE EL LS S H H2 20 00 00 0 H H2 25 50 00 0 H H3 30 00 00 0 H H3 35 50 00 0 L LC C3 30 0 L LC C5 50 0...

Страница 2: ...y is null and void unless the Hague Appliance was purchased from an independent Hague dealer THERE ARE NO WARRANTIES OTHER THAN THOSE DESCRIBED IN THIS WARRANTY INSTRUMENT This warranty does not cover...

Страница 3: ...LLATION AND MAINTENANCE INFORMATION 13 Checklist Before Installation 13 Installation Tool List 14 Installation Diagram 15 Typical Flow Diagram 16 Booster Pump Retrofit Diagrams 17 Installation Steps a...

Страница 4: ...ht to make specification and product changes without prior notice This manual is for installation operation and maintenance of the following RO appliance models x WaterMax H2000 x WaterMax H3500 x Wat...

Страница 5: ...service this appliance Important Meeting operational maintenance and replacement requirements are essential for this product to perform to specifications Hague recommends that the storage tank be drai...

Страница 6: ...g Water Appliances replenish at about one half gallon per hour depending on your tap water pressure and the water temperature Low water pressure and temperature will cause all RO appliances to produce...

Страница 7: ...Max RO Drinking Water Appliance is designed to be used on cold water only Never run warm or hot water through your appliance Caution Connect to the cold water supply only Warning Do not allow your app...

Страница 8: ...ance Models H2000 H2500 H3000 LC30 LC50 and LC100 If you are using softened water replace your Sediment Pre Filter annually If you are not using softened water the replacement interval will vary Every...

Страница 9: ...monitoring devices or water check programs Note If your WaterMax RO appliance is installed on a soft water supply it will greatly increase the life of the membrane Third Stage Carbon Post Filter The A...

Страница 10: ...installed where the water source is microbiologically unsafe or of unknown quality without adequate disinfection before and or after the appliance A water source that is not potable relative to waterb...

Страница 11: ...ivated carbon as pretreatment for chlorine CAUTION Contaminants in excess of the established limits will require pretreatment WARNING Do not use with water that is microbiologically unsafe or of unkno...

Страница 12: ...blications ordpubs html Private water supplies and waters that do not have detectable free chlorine residuals should be analyzed to determine the form s of arsenic present and the potential need for o...

Страница 13: ...bing codes To prevent back siphoning provide an adequate air gap or a siphon break See Installation Steps and Start Up Procedures Water Characteristics pH The appliance requires a pH of between 5 0 an...

Страница 14: ...ank for non air gap spigot Air pressure test gauge 1 20 psi 1 inch High speed drill bit with 1 2 inch shank for air gap spigot 7 8 inch chassis punch 1 2 inch Drill motor for 1 inch high speed drill b...

Страница 15: ...tallation Diagram Notes 1 For maximum flow keep yellow tubing to tank and blue tubing to spigot as short as practical 2 Install feed water line on COLD WATER LINE ONLY 3 Installation procedures for th...

Страница 16: ...Typical Flow Diagram Air Gap Silencer for H3500 and H2500 Figure 3 WaterMax H3500 Flow Diagram WaterMax RO Owner s Manual 11 11 2009 16...

Страница 17: ...rofit Diagrams WaterMax H2000 For retrofit instructions see form F0873 Figure 4 WaterMax H2000 WaterMax H3000 For retrofit instructions see form F0874 Figure 5 WaterMax H3000 WaterMax RO Owner s Manua...

Страница 18: ...ameter be free of score marks and that burrs and sharp edges be removed before inserting into fitting Insert the locking clip The locking clip secures the collet in its position to prevent an accident...

Страница 19: ...ron sink A Mark the sink location for the center of the faucet Be sure the location you select is not over a reinforcing rib Check the location from below B Grind away a 1 1 4 inch diameter circle in...

Страница 20: ...4 inch black tube onto the small hose barb on the base of the spigot C Slip one end of the loose 3 8 inch black tube over the large hose barb on the base of the spigot Installation Tip To make it eas...

Страница 21: ...ect the riser tube to the other end of the feed water supply valve Do not overtighten Caution A longer riser tube assembly will be required if a gentle loop cannot be made See Figure 8 E Remove the re...

Страница 22: ...el off the white backing from the drain gasket and apply the gasket to the port connection of the drain saddle See Figure 15 Make sure to align the drain saddle to the drilled hole Attach the drain sa...

Страница 23: ...place B Turn on the feed water and check for leaks C Open the valve on top of the storage tank D The appliance is now in operation tep 9 Operation Procedure A Operation of the appliance will require t...

Страница 24: ...visibly dirty discard it 6 Wash out the filter housing using warm soapy water and rinse thoroughly 7 Sanitize the appliance See Sanitizing the WaterMax RO Appliance 8 Be sure the O Ring is properly s...

Страница 25: ...ater supply valve 3 Lift the black handle of the dispensing spigot and wait at least five minutes for the pressure to be relieved from the system 4 Remove the Carbon Pre Filter housing by turning it c...

Страница 26: ...the O Rings on the pressure vessel end cap and lubricate with glycerin Replace if damaged or out of round 10 Replace the end cap by turning clockwise 11 Reattach the tubing to the pressure vessel end...

Страница 27: ...d then rinse thoroughly with clear water to flush away any soap residue Note Be sure all carbon pre and post filters are removed during the sanitizing procedure 4 Insert the new cartridge s for the sp...

Страница 28: ...bottlebrush and then rinse thoroughly with clear water to flush away any soap residue 2 Insert the new cartridge for the specified model Caution Do not touch the filter with your bare hands Peel the w...

Страница 29: ...ts Feed Water Service Valve Assembly 2 1 Figure 13 Feed Water Assembly Part Description Quantity 1 200540 Feed Water Service Valve Assembly 1 2 200200 1 4 inch Locking clip 1 WaterMax RO Owner s Manua...

Страница 30: ...O Air Gap Spigot Lead Free Part Description Quantity 1 202310 Filter housing wrench 1 2 200350 Air gap spigot assembly 1 3 200360 Spigot adapter 3 8 inch x 7 16 inch J G 1 4 200199 Locking clip 3 8 in...

Страница 31: ...arts Cont Drain Saddle Assembly Figure 15 Drain Saddle Assembly Part Description Quantity 1 200130JG Drain saddle assembly 2 Piece Plastic 1 2 200199 3 8 inch Locking clip 1 WaterMax RO Owner s Manual...

Страница 32: ...Assembly and Parts Cont RO Assembly Front View Figure 16 RO Assembly Front View WaterMax RO Owner s Manual 11 11 2009 32...

Страница 33: ...12 inch H3000 H3500 LC30 1 15 200191 Inline nitrate filter Optional 1 16 201165 Pressure vessel O Ring 1 17 200300 CTA membrane 16 GPD H2000 H2500 1 18 200290 TFC membrane 24 GPD H3000 H3500 1 19 2002...

Страница 34: ...Assembly and Parts Cont RO Assembly Back View Figure 17 RO Assembly Back View WaterMax RO Owner s Manual 11 11 2009 34...

Страница 35: ...1 4 inch x 1 4 inch 1 9 202356 Reducing tee 3 8 inch x 3 8 inch x 1 4 inch Plastic 1 10 PAMC Mounting clip permeate pump 1 11 PAM1000 Permeate pump H2500 H3500 LC50P LC100P 1 12 200095 16 Flow restri...

Страница 36: ...Assembly and Parts Cont RO Assembly Top Back View Figure 18 RO Assembly Top Back View WaterMax RO Owner s Manual 11 11 2009 36...

Страница 37: ...99 Locking clip 3 8 inch 3 9 90816 Male elbow 3 8 inch x 1 4 inch Plastic 1 10 202349 Plug in elbow 1 4 inch tube x 1 4 inch Stem 3 11 200245CJG Membrane housing cap black with O Ring 1 12 201030 Male...

Страница 38: ...rage Tank Assembly Part Description Quantity 1 201140 Tank shutoff valve 3 8 inch x 1 4 inch plastic 1 2 200199 3 8 inch Locking clip 1 3 200100 RO storage tank 3 1 gallon capacity black 1 4 200030 Ta...

Страница 39: ...p Kit P N PAB6800KIT Figure 20 Parts Booster Pump Kit Part Description Quantity 1 PAB6800 Booster pump 1 2 PAT115 Transformer 24VAC 1 3 PAW260 Pressure switch 1 4 200910 1 4 inch x 5 foot tubing red 1...

Страница 40: ...pump 1 202349 Plug in elbow 1 4 inch tube x 1 4 inch stem 4 PAMC Mounting clip permeate pump 1 200500 Screw 10 32 x 1 2 inch Phillips 2 200501 Hex nut 10 32 Nylock 2 PAMASV Permeate pump shut off valv...

Страница 41: ...ater shut off Turn on your feed water valve Low feed pressure See Filter Specifications chart to verify minimum feed pressure for your model A pre filter cartridge clogged Replace the clogged pre filt...

Страница 42: ...cube mold shape make cubes manually if using automatic Let water sit to release dissolved air before freezing RO membrane is bad Membrane fouled hydrolyzed ruptured or attacked by bacteria Replace mem...

Страница 43: ...bon Block 5 Micron Sediment GAC 5 Micron 20 inch Sediment GAC 5 Micron 20 inch Sediment GAC PCF N A N A Standard Standard Standard N A N A Postfilter GAC GAC GAC GAC GAC GAC GAC Height inches 15 1 4 1...

Страница 44: ...Certificates WaterMax RO Owner s Manual 11 11 2009 44...

Страница 45: ...Certificates Cont WaterMax RO Owner s Manual 11 11 2009 45...

Страница 46: ...Notes...

Страница 47: ...Notes...

Страница 48: ...uality Association This validation assures that all electrical components are UL or CSA listed and all components that are in contact with the treated water are FDA or NSF listed Hague Quality Water I...

Отзывы: