EQUIPMENT SPECIFICATIONS - MODEL 96MM
Series 96 Owner’s Manual
35
Maximum compensated hardness*
90 gpg / 1,541 mg/l
Maximum ferrous iron reduction*
10 ppm reduced to below 0.3 ppm
Minimum pH
7
“Ultra-fil” self-cleaning sediment filtration
20 microns nominal
Salt use:Use clean, white pellet or solar salt.
1 lb* - 5,600 grain capacity - .45 kg at 362,880 mg
3 lb* - 15,400 grain capacity - 1.36 kg at 997,920 mg
6 lb - 24,500 grain capacity - 2.72 kg at 1,586,304 mg
9 lb* - 30,700 grain capacity - 4.1 kg at 1,989,360 mg
Media type
SUPERSAVER fine mesh cation resin
Media quantity
1 cu. ft, 28.3 l
Water pressure
20 to 120 psi, 138 to 828 kPa
Flow rate (as tested by Hague)
@ 15 psi / 103.4 kPa pressure drop
11 gpm / 41.7 lpm at 103.4 kPa pressure drop
Rated Flow
8 gpm @ 10 psi pressure drop
Maximum flow to drain during regeneration
2.4 gpm / 9.12 lpm
Maximum flow to drain during regeneration
3.0 gpm / 11.4 lpm (96MM B1 or P1 only)
Flow rates:
Backwash 2.4 gpm / 9.12 lpm
Brine & Rinse Total .65 gpm
Brine Draw .25 gpm / 1.5 lpm
Rinse .4 gpm / 1.5 lpm/ Service 8 gpm at 10 psi pressure
drop 30.2 lpm at 68.9 kPa pressure drop
Minimum water temperature
40°F, 6°C
Maximum water temperature
120°F, 49°C
Min./Max. ambient temperature
40°F-120°F
Plumbing connection
3/4" or 1" copper pipe
Salt storage capacity
200 lb, 90 kg
Electrical rating
115V, 60 cycle
Unit size
38" H x 15" W x 30" D
96.5 cm H x 38.1 cm W x 76.1 cm D
*1lb, 3 lb and 9 lb settings were tested and certified by WQA. The maximum compensated hardness, maximum ferrous iron
reduction, and 6 lb setting were not tested and certified by WQA.
Model 96MM is the only model tested and certified by WQA.
96MM is efficiency rated according to NSF/ANSI 44. The stated
efficiency is valid only at the specified salt dosage:
Rated efficiency
Salt Dosage
Capacity at that Dosage
5,600 grains/lb
1.0 lbs
5,600 grains
OPERATIONAL, MAINTENANCE, AND REPLACEMENT REQUIREMENTS ARE ESSENTIAL FOR THE
PRODUCT TO PERFORM TO SPECIFICATIONS.
Conforms to NSF/ANSI Standard 44 for Softening Performance Efficiency, Barium Reduction, and Radium 226/228 Reduction. Water softeners using
sodium chloride for regeneration add sodium to the water. Persons who are on sodium restricted diets should consider the added sodium as part of their
overall sodium intake.
™
Содержание Maximizer
Страница 1: ...Series 96 Owner s Manual REV 2 0...
Страница 33: ...SERIES 96 SAFETY SHUTOFF ASSEMBLY Series 96 Owner s Manual 31 Figure 11...
Страница 39: ...Series 96 Owner s Manual 37...