Figure 2
SERVICE SETTINGS
This section is recommended for qualified service personnel
only. The appliance control must be set correctly for proper
performance.
REGENERATE
FUNCTION
: Multi-purpose. 1.) Used to put the appliance
into an immediate regeneration. Press and hold (approximately
5 seconds) until display changes to “Going to 1”. The appliance
is now in regeneration and will return to “Gal. Remain” after
completion of all cycles. 2.) Used to “speed up” or toggle
through all the regeneration cycles.
CUSTOMER SETTINGS
This section is recommended for qualified service personnel
only. Must be set correctly for proper performance.
CHANGE
FUNCTION
: Used to change values of parameters that can be set. Used in conjunction with SELECT button.
Press and release the Select button to move cursor one digit to the right of parameter that can be set. When cursor is
at extreme right position, press again to reset cursor to extreme left position.
SELECT
FUNCTION
: Used to control cursor movement when in CUSTOMER & SERVICE SETTINGS modes. Used in
conjunction with CHANGE button. Press and release the Select button to move cursor one digit to the right of
parameter that can be set. When cursor is at extreme right position, press again to reset cursor to extreme left
position.
DISPLAY
FUNCTION
: When pressed and held, “CUSTOMER SETTINGS” is displayed. Hold for 5 seconds and the
customer programming mode is entered. Used simultaneously with the SELECT button to enter service settings
program mode, press and hold both buttons for 5 seconds while holding “SERVICE SETTINGS” is displayed.
(Note: both buttons must be pressed.)
SCROLL BACK
FUNCTION
: Used to toggle back to the previous parameter setting in the event of a mistake in programming.
This feature eliminates the need to toggle through the entire program to correct an input error.
CONTROL PANEL DISPLAY
Note: It is normal to see the display area toggle between “Gal. Remain”, “Flow
GPM” and “Days to Regen” (Mode 1 only).
FUNCTION
: Shows status of control; NORMAL OPERATING mode, SERVICE SETTINGS mode or
CUSTOMER SETTING mode. It is very important to know which mode the control is in for proper operation.
WATER FLOWING INDICATOR
FUNCTION
: Shown in the LCD display, it indicates that water is flowing through the Series 96. Flow rate is
displayed in gallons per minute. This is useful for checking for proper plumbing and leaks.