32/64
CMp
| Technical data
Bosch Rexroth AB, RE 15409 Version 08.2022,
Table 18: Electrical /technical data flow sensors
SLSP 21
SLSP 22
SLSP 23
Operating voltage [V]
19-30 DC
Analogue current output [mA]
4-20
Measuring range [l/min]
0-50
0-100
0-200
Ambient temperature [°C]
-10 to 60
Storage temperature [°C]
-25 to 80
Medium temperature [°C]
-10 to 80
Protection
IP 67
Pressure rating [bar]
16
Pin connection
Pin 1
+ Supply voltage L+
Pin 2
+ Signal (4...20 mA)
Pin 3
Supply voltage / -Signal
Pin 4
L-
Note!
When installing this sensor you have to change parameter "MEDI" to OIL1.
Table 19:
Settings of flow sensors
Factory settings
User settings
SU7000
SU8000
SU9000
SP1
10.0
20.0
40.0
Factory settings
rP1
5.0
10.0
20.0
ImPS
0.1
0.1
0.1
ImPR
YES
YES
YES
OU1
Hno
Hno
Hno
OU2
I
I
I
SP2 (FLOW)
40.0
80.0
160.0
rP2 (FLOW)
30.0
60.0
120.0
SP2 (TEMP)
62.0
62.0
62.0
rP2 (TEMP)
44.0
44.0
44.0
ASP (FLOW)
0.0
0.0
0.0
AEP (FLOW)
50.0
100.0
200.0
ASP (TEMP)
-10.0
-10.0
-10.0
AEP (TEMP)
80.0
80.0
80.0
Din 2
+EDG
+EDG
+EDG
CGA
100
100
100
FOU1
OFF
OFF
OFF
FOU2
OFF
OFF
OFF
dST
0.0
0.0
0.0
P-n
Pnp
Pnp
Pnp
dAP
0.6
0.6
0.6
rTo
OFF
OFF
OFF
diS
d2
d2
d2
Uni
Lmin
Lmin
Lmin
SELd
FLOW
FLOW
FLOW
SEL2
FLOW
FLOW
FLOW
MEDI
H2O
H2O
H2O
OIL 1
Fig. 29:
Contact flow sensors
42591