Location requirements
Sealing the embedded base
Assembling the embedded base
conduit opening
locknuts
washers
base
nuts
threaded
angle
rods
Undo the
4 locknuts
once the concrete
has hardened.
If chemical sealing is employed, Ø 12
mm threaded rods should be used
Installing the embedded base
Before you embed the base, make sure that all the necessary cables and conduits have been run from the cabinet to the terminal.
1
3
2
19
The base takes 2 x Ø 60
mm conduits for the terminal
power supply cables and 2
x Ø 40 mm conduits for the
communication cables.
100 mm